Shanghai Youyi DHG-9023A Precision Forced-Air Drying Oven

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Shanghai Youyi / shyy
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Product Category Domestic
Model DHG-9023A
Instrument Type Precision Drying Oven
Temperature Range RT+20°C to 280°C
Temperature Uniformity ±2.5%
Temperature Fluctuation ±1°C
Temperature Resolution 0.1°C
External Dimensions 625 × 540 × 500 mm
Internal Chamber Dimensions 340 × 330 × 320 mm
Chamber Volume 20 L
Chamber Material Mirror-Finish Stainless Steel (SUS304)
Heating Method Electric Resistance Heating
Power Supply AC 220 V, 50 Hz
Input Power 850 W
Working Environment Ambient Temperature 5–40°C, Humidity ≤80% RH (non-condensing)
Compliance GB/T 30435–2013

Overview

The Shanghai Youyi DHG-9023A is a compact, microprocessor-controlled forced-air drying oven engineered for precision thermal processing in research laboratories, quality control environments, and industrial R&D settings. It operates on the principle of convection-based heat transfer, utilizing an optimized rear-mounted air circulation system with adjustable intake and exhaust ports to ensure uniform temperature distribution across the 20 L stainless-steel chamber. Designed in strict accordance with GB/T 30435–2013 (the Chinese national standard for electric hot-air drying ovens), the DHG-9023A delivers stable thermal performance under both static and dynamic load conditions—making it suitable for applications requiring reproducible drying, baking, sterilization, moisture removal, or pre-conditioning of samples prior to analytical testing.

Key Features

  • Intelligent microcomputer PID temperature control system with real-time digital display, offering precise setpoint resolution of 0.1°C and long-term stability within ±1°C fluctuation (measured at empty chamber, ambient 20°C/50% RH).
  • High-efficiency forced-air circulation architecture featuring a rear-mounted blower, dual-direction airflow ducts, and automatic humidity exhaust—eliminating manual vent adjustment and minimizing condensation buildup during extended operation.
  • Double-layer tempered glass observation window with integrated silicone gasket seal, enabling non-intrusive visual monitoring while maintaining thermal integrity and operator safety.
  • Robust mechanical construction: cold-rolled steel exterior with electrostatic epoxy-polyester coating; interior chamber fabricated from electropolished SUS304 stainless steel for corrosion resistance, cleanability, and compliance with GLP documentation requirements.
  • Comprehensive safety architecture including over-temperature cut-off protection (independent limit controller optional), power-failure data retention, auto-restart function upon recovery, and audible/visual alarm activation when deviation thresholds are exceeded.
  • Modular expansion interface supporting RS485 communication (with optional PC software), embedded thermal printer output, inert gas purging port with calibrated float-type flowmeter (0–10 L/min range), and configurable test ports (25 mm or 50 mm diameter).

Sample Compatibility & Compliance

The DHG-9023A accommodates a broad spectrum of sample types—including polymer films, pharmaceutical excipients, biological tissue sections, ceramic precursors, electronic components, and calibration standards—without risk of cross-contamination or surface oxidation, thanks to its inert stainless-steel chamber and absence of catalytic internal coatings. Its operational envelope (RT+20°C to 280°C) supports common thermal protocols aligned with ASTM D1654 (corrosion testing), ISO 17025 clause 5.4.2 (equipment qualification), and USP (sterilization by dry heat). While not certified to IEC 61000-4 electromagnetic compatibility standards out-of-box, the unit meets basic CE-equivalent EMC and LVD safety expectations for laboratory use in non-hazardous locations. Full traceable calibration reports and IQ/OQ documentation templates are available upon request for GMP-regulated facilities.

Software & Data Management

When equipped with the optional RS485 interface and companion Windows-based software, the DHG-9023A enables time-stamped logging of chamber temperature, setpoint history, alarm events, and runtime duration at user-defined intervals (1 s to 60 min). Data export is supported in CSV and Excel-compatible formats, facilitating integration into LIMS platforms or statistical process control (SPC) workflows. The embedded printer option provides hard-copy audit trails compliant with FDA 21 CFR Part 11 requirements when paired with appropriate electronic signature validation procedures. All parameter configurations—including ramp-soak profiles via the optional multi-segment programmable controller—are stored in non-volatile memory and survive power interruptions without corruption.

Applications

  • Drying of moisture-sensitive powders and granules in pharmaceutical formulation development.
  • Baking of printed circuit board (PCB) substrates prior to solder paste application.
  • Thermal aging studies of elastomers and thermoplastics per ISO 188.
  • Residual solvent evaporation from HPLC vial inserts and GC sample preparation vessels.
  • Pre-drying of filter papers, crucibles, and weighing boats in gravimetric analysis workflows.
  • Heat treatment of calibration reference materials before NIST-traceable mass determination.
  • Moisture content verification in agricultural feedstock using AOAC 934.01 methodology.

FAQ

What is the maximum recommended operating temperature for continuous use?
The DHG-9023A is rated for sustained operation up to 250°C; 280°C is specified as the upper limit for short-duration (<30 min) thermal validation cycles only.
Does the oven support programmable ramp-and-soak profiles?
Yes—when fitted with the optional multi-segment programmable temperature controller (additional cost), users can define up to 30 segments with independent ramp rates, dwell times, and cycle repeats.
Can the chamber be purged with nitrogen or argon?
Yes—the optional inert gas inlet includes a calibrated float flowmeter (range 0–10 L/min) and quick-connect fitting compatible with standard laboratory gas manifolds.
Is third-party calibration certification available?
Shanghai Youyi provides factory calibration certificates (traceable to CNAS-accredited labs); full UKAS/NIST-traceable calibration with uncertainty budgets may be arranged through authorized service partners.
What maintenance is required to sustain temperature uniformity over time?
Annual verification of fan speed, door seal integrity, and sensor linearity is recommended; routine cleaning of the air intake filter and chamber interior with isopropyl alcohol ensures optimal airflow and minimizes particulate accumulation.