Empowering Scientific Discovery

Yoyilab DHG-9030A Precision Forced-Air Drying Oven

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Yoyilab
Origin Shanghai, China
Manufacturer Yoyilab
Model DHG-9030A
Temperature Range RT+10°C to 250°C
Temperature Uniformity ±2.5% (at 100°C)
Temperature Fluctuation ±1°C
Temperature Resolution 0.1°C
Internal Dimensions (W×D×H) 340×330×320 mm
External Dimensions (W×D×H) 625×540×500 mm
Chamber Volume 30 L
Interior Material Mirror-Finish Stainless Steel
Heating Method Electric Resistance Heating
Power Input 850 W
Air Circulation Forced-air via Rear-Mounted Centrifugal Blower
Compliance GB/T 30435–2013

Overview

The Yoyilab DHG-9030A is a compact, microprocessor-controlled forced-air drying oven engineered for precision thermal processing in research laboratories, quality control environments, and industrial R&D settings. It operates on the principle of convective heat transfer enhanced by a rear-mounted centrifugal blower, ensuring consistent airflow distribution across the chamber. This architecture enables uniform temperature distribution—critical for applications requiring reproducible drying, curing, sterilization, or moisture removal where spatial thermal gradients must be minimized. Designed to meet GB/T 30435–2013 standards for electric heating drying ovens, the DHG-9030A delivers stable thermal performance within a working range of RT+10°C to 250°C, with a typical temperature fluctuation of ±1°C and uniformity of ±2.5% at 100°C (measured under no-load, vibration-free, ambient conditions at 20°C/50% RH). Its 30 L stainless-steel chamber accommodates standard laboratory glassware, petri dishes, filter papers, and small component assemblies without compromising thermal integrity.

Key Features

  • Intelligent microcomputer PID temperature controller with digital LCD interface: displays setpoint, real-time chamber temperature, and remaining timer duration simultaneously
  • Programmable timer with 1–9999 minute range; automatic shut-off upon completion
  • Dual-layer tempered glass observation window with large viewing area for non-intrusive process monitoring
  • High-efficiency air circulation system featuring adjustable rear air inlet/outlet ports and optimized duct geometry to minimize condensation buildup and accelerate moisture evacuation
  • Robust construction: cold-rolled steel exterior with electrostatic epoxy-polyester coating; mirror-finish 304 stainless-steel interior resistant to corrosion and repeated cleaning
  • High-temperature silicone door gasket ensures long-term sealing integrity and thermal insulation efficiency
  • Independent over-temperature protection circuit (optional): cuts power if chamber exceeds user-defined safety limit, complying with IEC 61000-4-2 ESD immunity requirements
  • Modular design supports optional accessories including RS485 communication interface, embedded thermal printer, inert gas purging port with calibrated rotameter, and multi-segment programmable controller

Sample Compatibility & Compliance

The DHG-9030A is suitable for drying, baking, annealing, and low-temperature sterilization of non-volatile, thermally stable samples—including polymer films, ceramic precursors, pharmaceutical excipients, soil aggregates, botanical extracts, and electronic substrates. It is not intended for flammable solvents, volatile organic compounds, or biological materials requiring biosafety containment. The unit complies with GB/T 30435–2013 for electrical safety, thermal stability, and performance verification under standardized test conditions. While not certified to UL, CE, or FDA 21 CFR Part 11 out-of-the-box, its architecture supports integration into GLP/GMP workflows when paired with validated data logging systems (e.g., via RS485 + compliant software), enabling audit-ready temperature traceability and electronic signature capability.

Software & Data Management

Standard operation requires no external software—temperature setpoints, timing sequences, and alarm thresholds are configured directly via the front-panel interface. Optional RS485 serial interface (Modbus RTU protocol) enables bidirectional communication with SCADA platforms, LIMS, or custom Python-based acquisition scripts for automated data capture. When equipped with the embedded thermal printer, time-stamped temperature logs can be generated locally for immediate documentation. All parameter configurations—including user-defined limits and timer presets—are retained during power interruption via non-volatile memory, supporting continuity in regulated environments where procedural repeatability is mandatory.

Applications

  • Moisture content determination per ASTM D2216 and ISO 11465 in soils, aggregates, and powdered chemicals
  • Pre- and post-weighing desiccation of filter media in environmental particulate analysis (e.g., PM2.5 gravimetric sampling)
  • Curing of epoxy-coated substrates and printed circuit board laminates prior to electrical testing
  • Drying of lyophilized intermediates and excipient blends in pharmaceutical development labs
  • Thermal conditioning of reference standards and calibration weights per ISO/IEC 17025 requirements
  • Accelerated aging studies of polymeric packaging materials per ASTM F1980
  • Heat treatment of metallographic specimens before microstructural analysis

FAQ

What is the maximum operating temperature of the DHG-9030A?
The unit is rated for continuous operation up to 250°C, with thermal cut-off protection activated above this threshold.
Does the oven support inert atmosphere operation?
Yes—when fitted with the optional inert gas inlet kit (including stainless-steel fitting and calibrated float-type flowmeter), nitrogen or argon can be introduced to suppress oxidation during heat treatment.
Can temperature uniformity be verified independently?
Yes—users may perform IQ/OQ validation using calibrated PT100 probes placed at prescribed locations (e.g., center, corners, mid-height) per ISO 17025 Annex A guidelines.
Is the DHG-9030A suitable for GMP-regulated environments?
It meets foundational hardware requirements; full compliance depends on integration with validated data logging, access controls, and change management protocols as defined in Annex 11.
How many shelf positions are available inside the chamber?
Two adjustable stainless-steel wire shelves are included, with multiple height-adjustment notches for flexible sample arrangement.