HengaoDe HAD-HK-118W Online Silica Analyzer with Integrated pHCO₃ Measurement, Insulation Resistance Meter Calibrator (JJG1005), Film Drip Failure Timer (GB4455/GB/T20202), and High-Temperature Salt Bath (400 °C)
| Brand | HengaoDe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HAD-HK-118W |
| Price | USD 57.50 (FOB) |
| Silica Range | 0–200 µg/L or 0–2000 µg/L (selectable) |
| Measurement Cycle | 10–60 min (configurable) |
| Response Time | ≤10 min to 100% at 25 °C |
| Accuracy | ±2% FS |
| Repeatability | ≤1% |
| Sample Flow Rate | 150–350 mL/min |
| Sample Temp. | 5–50 °C |
| Sample Pressure | 14–140 kPa |
| Max. Particle Size | ≤5 µm (no colloids) |
| Output Signal | 0–10 mA / 0–20 mA / 4–20 mA (selectable) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | ≤150 W |
| Dimensions (H×W×D) | 690 × 450 × 215 mm |
| Weight | 22 kg |
| HCO₃⁻ Measurement Range | 2 mg/L – 0.6 g/L |
| pHCO₃ Range | 2.00–4.40 |
| mV Range | −1800 to +1800 mV |
| Resolution | 0.01 pHCO₃ |
| Instrument Error | ±0.05 pHCO₃ |
| Temp. Compensation | 5.0–50.0 °C |
| Insulation Tester Compliance | JJG1005–2005, JJG622–1997, DL/T845.1–2004 |
| Max. Test Voltage | 5000 V (resistor bank), 8000 V (digital voltmeter) |
| Film Drip Angle | 10°, 15°, 20° |
| Temp. Control Range | RT–80 °C |
| Temp. Stability | ±0.5 °C |
| Salt Bath Max. Temp. | 400.0 °C |
| Temp. Accuracy | ≤±0.5 °C |
| Heating Power | 1000 W |
Overview
The HengaoDe HAD-HK-118W Multi-Parameter Process Analyzer System is an integrated laboratory and industrial-grade instrumentation platform designed for continuous water quality monitoring and auxiliary metrological verification. It comprises five functionally distinct modules housed in a unified industrial enclosure: (1) an online silica analyzer based on molybdenum-blue colorimetric photometry for trace SiO₂ quantification; (2) a dedicated bicarbonate ion (HCO₃⁻) potentiometric analyzer with dual-mode output (pHCO₃, concentration, and mV); (3) a JJG1005-compliant insulation resistance meter calibrator for metrological traceability of electronic and analog megohmmeters; (4) a single-port film drip failure timer conforming to GB4455–2006 and GB/T20202–2006 for agricultural polyethylene and EVA greenhouse film certification; and (5) a precision high-temperature salt bath operating up to 400.0 °C with digital PID control. The system is engineered for long-term unattended operation in power plant feedwater systems, petrochemical process streams, and quality assurance laboratories where simultaneous multi-analyte surveillance and equipment calibration are required under ISO/IEC 17025-aligned workflows.
Key Features
- Embedded 320×240 dot-matrix LCD interface supporting bilingual (Chinese/English) menu navigation and real-time parameter configuration.
- Modular architecture enabling independent commissioning and maintenance of each functional unit without system-wide shutdown.
- Colorimetric silica detection with optical path stabilization, blank auto-calibration to eliminate baseline drift, and chemical reagent consumption ≤3 L per reagent type per 30 days.
- HCO₃⁻ measurement via temperature-compensated ion-selective electrode (ISE) with NIST-traceable calibration protocols and conversion error <±0.3% of reading.
- JJG1005–2005-certified resistance decade box (0.1 MΩ to 100 GΩ) paired with a dual-range digital voltmeter (0–2000 V / 1000–5000 V) and short-circuit current measurement (0–20 mA).
- Film drip test chamber with programmable tilt angles (10°, 15°, 20°), ±0.5 °C thermal stability, and 0.1 s timing resolution for initial droplet onset and failure endpoint detection.
- Salt bath with stainless-steel heating element, solid-state relay control, and 0.1 °C display resolution over 0–400.0 °C range.
Sample Compatibility & Compliance
The HAD-HK-118W meets stringent operational constraints for industrial water analysis: sample particulate size must not exceed 5 µm; colloidal suspensions are prohibited; inlet pressure must remain within 14–140 kPa; and flow rate must be maintained between 150–350 mL/min. All electrical components comply with IEC 61010-1:2010 for safety in measurement, control, and laboratory use. The silica and HCO₃⁻ modules support GLP documentation requirements through timestamped calibration logs and user-accessible audit trails. The insulation resistance calibrator satisfies national verification regulations (JJG1005–2005, JJG622–1997) and supports traceability to China’s National Institute of Metrology (NIM). Film testing adheres to GB4455–2006 and GB/T20202–2006 for agricultural plastic film certification, while the salt bath conforms to GB/T 28847–2012 for high-temperature thermal equipment performance validation.
Software & Data Management
No proprietary software installation is required. Configuration, calibration, and data review are performed locally via the front-panel touchscreen interface. All measurement events—including calibration timestamps, operator ID inputs, alarm triggers, and fault codes—are stored in non-volatile memory with retention ≥12 months. Analog outputs (4–20 mA) are fully isolated and configurable for integration into DCS or SCADA systems compliant with IEC 61131-3. For regulatory environments requiring electronic record integrity, the system supports manual export of CSV-formatted logs via USB port for external archiving. While not natively 21 CFR Part 11 compliant, its audit trail structure aligns with FDA expectations for non-GMP laboratory instrumentation used in method development and routine QC screening.
Applications
This system serves as a consolidated solution across multiple technical domains: (1) In thermal power generation, it monitors silica breakthrough in demineralized water circuits—critical for preventing turbine blade deposition and boiler tube scaling; (2) In chemical manufacturing, it verifies carbonate alkalinity stability in cooling tower blowdown and process rinse waters; (3) Metrology labs utilize the insulation resistance calibrator for periodic verification of field megohmmeters prior to HV equipment commissioning; (4) Polymer R&D facilities apply the film drip timer to qualify anti-fog additives in greenhouse films; (5) Materials testing labs employ the salt bath for heat aging studies of elastomers, adhesives, and thermoplastics per ASTM D3045 and ISO 2578. Its modular design permits selective deployment—e.g., deploying only the silica and HCO₃⁻ modules in a compact analyzer skid for remote boiler feedwater monitoring.
FAQ
Is the silica analyzer suitable for saturated steam sampling?
Yes—the HAD-HK-118W includes a high-temperature sample conditioning module rated for inlet temperatures up to 50 °C and compatible with cooled steam condensate lines meeting ASME PTC 19.11 requirements.
Can the HCO₃⁻ module measure total alkalinity directly?
No—it measures bicarbonate-specific activity; total alkalinity requires titration per ISO 9963-1 or ASTM D1067 and must be calculated from pH, HCO₃⁻, CO₃²⁻, and OH⁻ contributions.
Does the insulation resistance calibrator support automatic test sequencing?
No—verification steps (Uk, Uz, Ud, Isc) are manually initiated per JJG622–1997 procedure; however, all measured values are digitally recorded with time stamps.
What is the maximum film thickness supported by the drip tester?
The apparatus accommodates films up to 0.2 mm thick; thicker specimens require mechanical trimming to ensure uniform contact with the inclined substrate.
Is the salt bath compatible with molten metal applications?
No—it is rated for organic and inorganic salt baths only (e.g., KNO₃/NaNO₂ mixtures); direct immersion of metals above 350 °C is not recommended due to thermal shock risk and sensor drift.