HengaoDe HAD-KDY-1A Portable Silicon Wafer Resistivity Tester & Four-in-One Analytical Instrument Suite (Including Automated Purge-and-Trap System, Six-Gas Monitor, Toluene-Insoluble Counter, and Geiger Personal Dosimeter)
| Brand | HengaoDe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HAD-KDY-1A / HAD-T70-T80 / HAD-6S / JSY-2 / H165430 / HAD-FS61 / HAD-T20D / HAD-CO22 / ST-FD-101 / HAD-G16A |
| Price | USD 28.50 (FOB Beijing) |
Overview
The HengaoDe HAD-KDY-1A Portable Silicon Wafer Resistivity Tester is a compact, field-deployable instrument engineered for rapid, traceable measurement of bulk resistivity (0.01–199.9 Ω·cm) and sheet resistance (0.1–1999 Ω/sq) in semiconductor-grade silicon wafers, epitaxial layers, diffusion junctions, and conductive thin films (e.g., ITO, conductive rubber). Its dual-range恒流 source (0.1–10 mA DC, ±0.1% stability) and integrated 0.2% accurate digital voltmeter (0–199.9 mV, 100 µV sensitivity) enable direct four-probe-style evaluation without external calibration hardware—meeting the performance criteria of GB/T 1551–2018 (Standard Test Methods for Determination of Resistivity of Silicon Single Crystals). Complementing this core unit is an integrated analytical suite: an automated purge-and-trap system (HAD-T70/T80) compliant with EPA Method 502.2 and ISO 15681-2 for volatile organic compound (VOC) preconcentration; a six-parameter electrochemical/infrared gas monitor (HAD-6S) supporting simultaneous detection of formaldehyde, CO, CO₂, O₂, temperature, and humidity; a programmable toluene-insoluble (TI) counter (JSY-2) designed per GB/T 2291–2019 for coal tar pitch analysis; and a GM-tube-based personal dosimeter (H165430 & HAD-G16A) certified to GB/T 13161–2015 for Hp(10) monitoring in radiological workplaces.
Key Features
- Resistivity tester: Dual-range precision current source with real-time self-calibration capability; auto-zeroing voltage measurement circuitry; <1% measurement uncertainty across 0.01–100 Ω·cm range.
- Purge-and-trap system: 70/80-position VOA vial carousel; programmable heating zones (trap: 25–450 °C at >1800 °C/min ramp; transfer lines: up to 295 °C); selectable Tenax or tri-bed sorbent traps; adjustable purge flow (10–200 mL/min).
- Six-gas monitor: Pump-suction sampling (10-stage vacuum control); dual-display mode (ppm/mg/m³); onboard data logging (500 records); USB and RS232 interfaces; automatic temperature/humidity compensation for gas concentration calculations.
- Toluene-insoluble counter: Optical beam interruption sensing (insertion-type photodetector); 0–999-cycle counting with audible alarm (100-beep cycle, user-interruptible); IP54-rated enclosure for lab fume hood integration.
- Geiger dosimeters: Energy-compensated halogen-quenched GM tubes; dose rate range 0.01 µSv/h–100 mSv/h; cumulative dose tracking up to 99.99 mSv (H165430) or 9999 mSv (HAD-G16A); battery life >500 h; compliance with IEC 61526:2013 Annex B for personal dosimetry.
Sample Compatibility & Compliance
The suite supports solid, liquid, and gaseous matrices across agricultural, environmental, and industrial QA/QC workflows. The resistivity tester accommodates wafers ≥10 mm diameter and thickness ≤2 mm; the purge-and-trap system handles aqueous samples (drinking water, leachates), soil slurries (with auto-dilution), and food headspace extracts. Gas monitors meet EN 50104 (CO), EN 50105 (O₂), and ISO 16000-26 (formaldehyde) requirements. TI counter operation strictly follows the gravimetric extraction protocol defined in GB/T 2291–2019. All instruments comply with electromagnetic compatibility standards IEC 61326-1 and safety directive IEC 61010-1. Radiation detectors are type-tested per national metrological verification regulation JJG 393–2021.
Software & Data Management
No proprietary software installation is required. All units feature embedded firmware with non-volatile memory for parameter retention and audit trails. The HAD-6S and HAD-CO22 support CSV export via USB mass storage mode; historical readings include timestamp, sensor ID, ambient T/RH, and alarm flags. Dosimeters store dose history with event markers (threshold exceedance, low-battery warning). Data integrity meets GLP documentation requirements: time-stamped logs, no editable metadata, and immutable record structure. Optional SD card expansion (HAD-CO22) enables long-term trend analysis under ISO/IEC 17025 Clause 7.7.2.
Applications
- Semiconductor fabrication: In-line wafer screening for dopant uniformity and post-diffusion process validation.
- Environmental laboratories: VOC analysis in groundwater per EPA 502.2; formaldehyde emission testing from agro-based composites (e.g., rice-husk particleboard).
- Agricultural R&D: Quantification of toluene-insoluble fractions in biochar feedstocks and pyrolysis oils per ASTM D7265.
- Radiation safety programs: Routine personnel monitoring in fertilizer production facilities using KCl-based NPK blends (naturally occurring radioactive material, NORM).
- Food quality control: Headspace CO₂ monitoring in grain silos; CO detection in post-harvest fumigation chambers.
FAQ
Is the resistivity tester suitable for measuring heavily doped silicon?
Yes—within its 0.01–199.9 Ω·cm range, it maintains accuracy for phosphorus- or boron-doped wafers when used with standard four-point probe geometry.
Can the purge-and-trap system interface with third-party GC/MS platforms?
Yes—it features universal 1/8″ Swagelok inlet/outlet fittings and TTL-triggered start/stop signals compatible with Agilent, Thermo Fisher, and Shimadzu chromatography systems.
Does the six-gas monitor support formaldehyde calibration traceable to NIST standards?
Calibration is performed using certified gas mixtures (e.g., Scott Specialty Gases P/N FORMALDEHYDE-500-10L); instrument-specific correction factors are stored in EEPROM.
What is the service interval for GM tube replacement in the dosimeters?
GM tubes are rated for 1×10¹⁰ counts; typical field service life exceeds 5 years under normal occupational exposure conditions (≤1 mSv/year).
Are firmware updates available for the JSY-2 toluene-insoluble counter?
Firmware is field-upgradable via micro-USB; version history and release notes are published quarterly on the manufacturer’s technical support portal.






