Empowering Scientific Discovery

SYSTESTER GTR-704R Beverage Cap Seal Integrity Tester

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand SYSTESTER
Origin Shandong, China
Model GTR-704R
Test Range 10–15,000 s/100 mL (standard)
Resolution 0.1 s/100 mL
Specimen Count 1
Pressure Range 20 kPa
Pressure Accuracy ±0.01 kPa
Test Area 1.0 in² (0.25 in² / 0.1 in² optional)
Max Specimen Thickness ≤5 mm
Test Gas Clean Compressed Air (user-supplied)
Air Supply Pressure 0.3–1.0 MPa
Interface Ø6 mm pneumatic fitting
Dimensions (L×D×H) 370 × 320 × 220 mm
Power AC 220 V, 50 Hz
Net Weight 20 kg
Standards Compliance ISO 5636-5, ASTM D726, TAPPI T460, GB/T 36363–2018

Overview

The SYSTESTER GTR-704R Beverage Cap Seal Integrity Tester is a precision-engineered instrument designed to quantitatively assess the seal integrity of threaded and press-fit closures used on PET, HDPE, and glass beverage containers. It operates on the principle of air leakage rate measurement under controlled differential pressure—applying a regulated vacuum or positive pressure across the sealed cap-container interface and measuring the time required for a defined volume of air (100 mL) to pass through any micro-leak path. This gravimetric flow timing method delivers direct, traceable, and repeatable s/100 mL values—fully aligned with industry-standard permeability and leak-rate interpretations. Unlike qualitative bubble tests or subjective visual inspections, the GTR-704R provides objective, numeric pass/fail criteria that support statistical process control (SPC), batch release documentation, and regulatory audit readiness. Its architecture integrates pneumatic actuation, high-stability pressure regulation, and real-time flow timing logic—ensuring metrological consistency across shifts, operators, and production lines.

Key Features

  • One-touch automated test sequence: initiates clamping, pressure application, flow timing, and result calculation without manual intervention
  • Industrial-grade 7-inch TFT capacitive touchscreen with zero-layer navigation UI—designed for gloved operation and rapid workflow execution in QC labs and packaging lines
  • Pneumatically actuated clamping mechanism ensures consistent sealing force and eliminates operator-dependent variability
  • Multi-unit display capability: s/100 mL (primary), µm/Pa·s (for comparative permeability indexing), and configurable custom units via firmware
  • Integrated thermal-line printer outputs calibrated test reports—including date/time stamp, specimen ID, pressure setpoint, measured value, operator code, and pass/fail status per predefined limits
  • Auto-overload protection safeguards transducers and valves during pressure excursions or misloaded specimens
  • Standard RS-232 and optional Ethernet interfaces enable bidirectional communication with LIMS, MES, or SCADA systems for automated data archival and trend analysis

Sample Compatibility & Compliance

The GTR-704R accommodates standard beverage closure geometries—including 28 mm, 30 mm, 38 mm, and 48 mm screw caps—as well as sport-cap variants and child-resistant closures, when mounted on compatible fixtures (available as accessories). Specimens are secured using a vertically adjustable, spring-loaded platen with interchangeable silicone-sealing gaskets. The instrument supports testing per internationally recognized standards: ISO 5636-5 (determination of air permeance of paper and board), ASTM D726 (standard test method for resistance of paper to passage of air), TAPPI T460 (air resistance of paper), and GB/T 36363–2018 (plastic bottle cap seal integrity test methods). While originally developed for packaging QA, its validated methodology also meets internal specifications for pharmaceutical secondary packaging (e.g., vial stopper integrity screening) and conforms to GLP documentation requirements—including electronic signature support and full audit trail logging when paired with compliant software.

Software & Data Management

The embedded firmware includes built-in calibration management, user-access-level controls (admin/operator), and automatic generation of CFR Part 11–compliant audit trails—recording all parameter changes, test executions, and report prints with timestamps and operator IDs. Optional PC-based SYSTESTER DataLink software enables advanced functions: multi-instrument fleet monitoring, SPC charting (X̄/R, Cpk), automated report export to PDF/CSV/XLSX, and integration with enterprise quality databases via ODBC or REST API. All raw timing data, pressure profiles, and environmental metadata (ambient temperature/humidity logged via external sensor input) are retained locally on non-volatile memory for ≥12 months—supporting FDA, EMA, and NMPA inspection readiness.

Applications

  • Final quality assurance of carbonated soft drink, juice, and dairy beverage closures prior to case packing
  • Supplier qualification and incoming inspection of cap batches from OEM molding facilities
  • Root cause analysis of fill-loss incidents or shelf-life failures linked to seal degradation
  • Validation of cap liner material performance (e.g., EVOH, PE foam, aluminum foil composites) under accelerated aging conditions
  • Process optimization of torque application during capping—correlating seal integrity data with applied closure torque
  • Supporting ISO 22000 and FSSC 22000 food safety management system requirements for packaging integrity verification

FAQ

What types of beverage containers can be tested with the GTR-704R?

The instrument is optimized for rigid plastic (PET, PP, HDPE) and glass bottles with standard neck finishes; compatibility with flexible pouches or spouted caps requires custom fixture adaptation.
Is compressed air supply included with the system?

No—users must provide clean, oil-free, dry compressed air at 0.3–1.0 MPa; an inline coalescing filter and pressure regulator are supplied as standard.
Can the GTR-704R be used for sterile barrier validation in pharma applications?

It is not certified for ISO 11607 or ASTM F2338 helium leak testing; however, it serves as a robust screening tool for non-sterile secondary packaging integrity prior to sterilization.
How often does the system require calibration verification?

Annual traceable calibration against NIST-traceable pressure and flow standards is recommended; daily operational checks using certified reference leaks are supported via optional calibration kits.
Does the instrument meet FDA 21 CFR Part 11 requirements out-of-the-box?

Yes—the embedded firmware includes electronic signatures, role-based access control, and immutable audit logs; full compliance requires site-specific SOP implementation and IT validation.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0