| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EK-300iD / EK-3000iD |
| Instrument Type | Benchtop Solid Density Analyzer |
| Measurement Principle | Archimedean Buoyancy Method (Air Weight / (Air Weight − Immersed Weight) × Reference Liquid Density) |
| Density Range | 0–2.000 g/cm³ |
| Density Resolution | 0.001 g/cm³ (EK-300iD) / 0.01 g/cm³ (EK-3000iD) |
| Temperature Range | 0–100 °C |
| Minimum Sample Mass | 0.001 g |
| Reference Liquids | Water, Kerosene, or User-Defined Liquids (Density Input Range: 0.000–2.000 g/cm³) |
| Temperature Compensation | Automatic |
| Data Storage | 200 Records |
| Interface | RS-232 |
| Compliance | GLP/GMP/GCP Audit Trail Ready, ISO/IEC 17025 Support Enabled |
| Software | WinCT Data Acquisition Suite (Windows-compatible, Excel export, statistical analysis, graphing) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EK-300iD / GF-300D |
| Instrument Type | Buoyancy-Based Density Balance |
| Measurement Principle | Archimedes’ Principle |
| Weighing Capacity | 300 g (EK-300iD), 310 g (GF-300D) |
| Weighing Readability | 0.01 g (EK-300iD), 0.001 g (GF-300D) |
| Density Resolution | 0.001 g/cm³ |
| Display | Backlit LCD (16 mm character height, EK-iD series) |
| Stabilization Time | ≤1 s (GF-D series) |
| Internal Resolution | 1/10,000,000 |
| Environmental Response Modes | FAST / MID / SLOW |
| Calibration | Full-digital span calibration with user-adjustable reference weight input |
| Temperature Compensation | Direct water temperature or reference liquid density entry |
| Density Comparison Mode | Hi / OK / Lo alarm output (optional external relay module) |
| Auto Power-Off | Configurable after ≥10 min inactivity |
| Interface | RS-232C standard port |
| Software | WinCT v3.x (Windows-compatible, supports Excel/Office data export, statistical analysis, time-series logging, and chart-based visualization) |
| Compliance | Built-in GLP/GMP/ISO audit trail functions (date/time stamping, instrument ID, calibration history, operator ID, measurement statistics) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | RTF-2325 / RTF-2430 / RTF-1325 |
| Accuracy Class | 0.5 |
| Load Capacity Range | 1 kN to 300 kN |
| Test Width | 420 mm / 590 mm |
| Crosshead Speed | 0.0005–500 mm/min or 0.0005–1000 mm/min |
| Load Accuracy | ±0.5% of reading (standard), ±1% of reading (optional range) |
| Sampling Interval | 1 ms |
| Input Channels | Up to 13 |
| Display | Optional full-color capacitive touchscreen with real-time force-displacement curve plotting |
| Data Storage | ≥10 preconfigured test profiles with auto-save/resume on power cycle |
| Test Modes | Tensile, Compression, Flexural, Peel, Cyclic, Creep, Stress Relaxation |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4971 |
| Detection Aperture | 350 mm (W) × 80 / 150 / 230 mm (H) |
| Detection Sensitivity | Fe Ø0.3–0.7 mm |
| Conveyor Belt Width | 250 mm |
| Belt Length | 800 mm |
| Belt Speed | 10–60 m/min |
| Display | 7-inch color TFT LCD touchscreen |
| IP Rating | IP65 |
| Communication | Modbus RTU/TCP standard |
| Data Output | Ethernet + USB storage (PDF reports, histograms, X̄-R charts, trend plots) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | MCT-1150 |
| Type | Electromechanical Universal Testing Machine |
| Maximum Load Capacity | 2.5 kN |
| Effective Travel | 850 mm (STB-1225L) / 550 mm (STB-1225S) |
| Crosshead Speed Range | 0.05–1000 mm/min (adjustable in 0.01 mm/min increments) |
| Speed Accuracy | ±0.5% |
| Load Measurement Accuracy | ±1% of reading (within 1/1 to 1/500 of sensor rated capacity) |
| Automatic Load Range Switching | Up to 128× |
| Load Calibration | One-touch electronic calibration with integrated sensor diagnostics |
| Overload Protection | Yes |
| Travel Limiters | Dual-position (upper/lower) mechanical stops |
| Position Resolution | 0.001 mm (≤10 mm), 0.01 mm (>10 mm) |
| Dimensions (L×H×W) | 470 × 1450 × 335 mm (STB-1225L) / 470 × 1050 × 335 mm (STB-1225S) |
| Weight | 56 kg / 43 kg |
| Power Supply | AC 100 V, 1Φ, 50/60 Hz |
| Power Consumption | 350 VA |
| Operating Environment | 5–40 °C, 20–80 % RH |
| Data Acquisition Rate | 0.2 ms (with TACT interface) |
| Display | Optional full-color touchscreen interface |
| Control | PC-based test setup and execution |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | RV-10000A |
| Instrument Category | Vibrational Rheometer |
| Sample State | Liquid |
| Sample Viscosity Range | 0.3–25,000 mPa·s |
| Operating Frequency | 30 Hz |
| Vibration Amplitude | <1 mm |
| Repeatability | ±1% of full-scale reading |
| Temperature Control | Compatible with AX-SV-37 Circulating Bath |
| Sensor Material | Titanium-coated |
| Data Output | CSV (viscosity, temperature, shear stress) and JPEG plots to USB drive |
| Calibration | User-performed with deionized water reference |
| Measurement Stabilization Time | ≤20 s |
| Shear Rate Adjustment | Via programmable amplitude control |
| Compliance | Designed for GLP-compliant environments |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Type | Electromechanical Universal Testing Machine |
| Model | RTF |
| Load Accuracy | ±0.5% of reading (1/1 to 1/500 full scale) |
| Sampling Rate | 1 ms |
| Input Channels | Up to 13 |
| Drive System | Brushless AC servo motor with vector control |
| Transmission | Preloaded precision ball screw |
| Load Cell | ORIENTEC high-accuracy strain-gauge sensor |
| Frame Rigidity | Enhanced by 30% vs. prior generation |
| Optional | Full-color capacitive touchscreen HMI |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EJ-120D |
| Weighing Capacity | 120 g |
| Readability | 0.01 g |
| Density Resolution | 0.01 g/cm³ |
| Repeatability | 0.01 g |
| Pan Size | 110 mm |
| Display | Backlit LCD, 16 mm digit height |
| Interface Options | RS-232 or driver-free USB |
| Power Supply | AC adapter and rechargeable battery dual mode |
| Compliance | GLP/GMP/GCP and ISO-compliant calibration reporting |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | SV-10 |
| Instrument Type | Oscillatory Viscometer |
| Mounting Style | Benchtop Fixed |
| Operating Environment | High-Temperature Capable |
| Viscosity Range | 0.3 mPa·s to 10 Pa·s |
| Temperature Range | 0–160 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 1 °C/min |
| Vibration Frequency | 30 Hz |
| Amplitude | 1 mm |
| Repeatability | ±1% of reading (std. dev.) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | STB-1225L / STB-1225S |
| Max Load | 2.5 kN |
| Effective Stroke | 850 mm (STB-1225L) / 550 mm (STB-1225S) |
| Crosshead Speed Range | 0.05–1000 mm/min |
| Speed Resolution | 0.01 mm/min |
| Speed Accuracy | ±0.5% |
| Load Accuracy | ±1% of reading (within 1/1 to 1/500 of sensor rated capacity) |
| Auto Range Switching | up to 128× |
| Load Calibration | one-button sensor-integrated calibration with sensor identification |
| Overload Protection | yes |
| Travel Limiters | dual (upper/lower) |
| Dimensions (L×H×W) | 470×1450×335 mm (L) / 470×1050×335 mm (S) |
| Weight | 56 kg (L) / 43 kg (S) |
| Power Supply | AC 100 V, 1Φ, 50/60 Hz, 350 VA |
| Operating Environment | 5–40 °C, 20–80 %RH |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4971-E |
| Detection Sensitivity | Fe Ø0.3 mm / SUS Ø0.8 mm |
| Aperture Width | 350 mm |
| Aperture Height Options | 100 mm / 170 mm / 250 mm |
| Through-Height Options | 80 mm / 150 mm / 230 mm |
| Conveyor Belt Width | 250 mm |
| Conveyor Length | 800 mm |
| Display | 7-inch WVGA Color Touchscreen |
| IP Rating | IP65 |
| Communication | Standard Modbus RTU/TCP |
| Data Export | Ethernet + USB (PDF/Chart) |
| Product Memory | 1,000 Recipes |
| Construction | Stainless Steel Frame |
| Drive Mechanism | Direct Gear Drive |
Show next