Air Microbial Sampler
Filter
Showing 61–80 of 80 results
| Brand | SKC |
|---|---|
| Origin | USA |
| Product Type | Imported Air Sampling Filter Membranes |
| Material Options | Cellulose Ester (MCE), Polyvinyl Chloride (PVC), Polytetrafluoroethylene (PTFE), Polycarbonate (PC), Silver (Ag), Glass Fiber (GF), Quartz (QZ), Gelatin (GEL) |
| Available Diameters | 13 mm, 25 mm, 37 mm, 47 mm, 90 mm, 102 mm, 8×10 inch |
| Pore Sizes | 0.3–10 µm (material-dependent) |
| Packaging | 25–1000 pieces per box |
| Sterilization | Gamma-irradiated (Gelatin), Autoclavable (PTFE, PC, Ag, GF, QZ), Solvent-compatible (Ag, MCE, PTFE) |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | BioLite+ |
| Flow Rate | 62 L/min (max) |
| Max Backpressure | 850 mbar |
| Power Supply | 120 V AC or 230 V AC |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–95% RH |
| Noise Level | 61–66 dB(A) at 1 m |
| Dimensions | 162 × 209 × 303 mm |
| Weight | 7.25 kg |
| Enclosure | Steel housing with integrated handle |
| IP Rating | IP20 |
| Flow Control | Manual adjustment with built-in backpressure gauge |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | BioSampler® |
| Flow Rate | 12.5 L/min |
| Construction | Borosilicate Glass |
| Sterilization | Autoclavable |
| Sampling Duration | Up to 8 hours |
| Collection Medium | Aqueous or viscous liquid (e.g., ViaTrap® mineral oil) |
| Inlet/Outlet | Standard ground-glass joints |
| Compatible Pump | SKC BioLite® sonic-flow pump |
| Nozzle Configuration | Triple tangential jets at optimized angles |
| Particle Size Cut-off | Approx. ≤10 µm aerodynamic diameter (human inhalable fraction) |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | BioStage (228-9611) |
| Flow Rate | 28.3 L/min |
| Material | Anodized aluminum (inlet cone & base plate, autoclavable) |
| O-Ring | Duro 50 / BUNA-N (non-autoclavable) |
| Impaction Stage | 400 nozzles (0.25 mm diameter) |
| Cut-Off Size (D50) | 0.6 µm |
| Sampling Medium | 90–100 mm standard agar plates |
| Compliance | NIOSH Methods 0800 & 0801, ACGIH Bioaerosol Sampling Guidelines |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | QT30 / QuickTake 30 |
| Sampling Method | Six-Stage Andersen Impaction |
| Collection Efficiency | ≥98% |
| Operating Noise | ≤60 dB(A) |
| Power Supply | Rechargeable Li-ion Battery (5 h runtime) or AC/DC Adapter |
| Sampling Duration | 0–999 min adjustable |
| Petri Dish Size | 90 mm standard |
| Weight | 2.2 kg |
| Dimensions (Sampler) | 23.6 × 21.3 × 8.9 cm |
| Flow Calibration Device | SKC 4046 Digital Flow Calibrator |
| Flow Range | 2.5–300 L/min |
| Flow Accuracy | ±2% of reading or ±0.05 STD L/min (whichever is greater) |
| 4046 Dimensions | 183 × 64 × 53 mm |
| 4046 Power | 7.5 VDC ±1.5 V, peak current 300 mA |
| Manual Elevating Platform | max height 3 m, dual tray options (47×37 cm and 42×32 cm), aluminum construction with anti-slip rubber surface |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | V100 |
| Pricing | Available Upon Request |
| Flow Rates | 28.3 L/min, 50 L/min, 100 L/min |
| Display | Color LCD with Touch Interface |
| Data Storage | >500 Sampling Records |
| Connectivity | Ethernet & USB |
| Weight | 12 lbs (5.4 kg) |
| Dimensions | 10″ L × 8″ W × 7″ H (254 × 203 × 178 mm) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Exhaust Filter | 0.2 µm Sterile Vent Filter |
| Housing & Sampling Heads | 316 Stainless Steel + Microban®-Impregnated Kydex® |
| Sampling Methods | Andersen-style Impaction & Rotary Slit™ Impaction |
| Sampling Head Options | R2S (Rotary Slit Standard), RCG (Compressed Gas), RAS (Remote Access Sampling) |
| Remote Control | IR-enabled (Start/Stop/Pause/Resume) |
| Calibration | On-screen Test Plate Verification |
| Sampling Duration per Cycle | 0–120 min |
| Programmable Parameters | Delay Time, Start Time, Sample Duration, Number of Cycles, Inter-Cycle Pause |
| Print Output | Thermal Label + Direct Thermal Paper |
| Sampling Capacity | >300 Agar Plates per Full Memory Cycle |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | SW1 |
| Pricing | Upon Request |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-10-800 |
| Sampling Principle | Inertial Impaction |
| Flow Rate | 28.3 L/min |
| Operating Humidity Range | 0–95% RH (non-condensing) |
| Stage Configuration | 6-stage cascade impactor with defined aerodynamic cut-points |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-10-800X |
| Sampling Principle | Inertial Impaction |
| Flow Rate | 28.3 L/min |
| Operating Temperature | <35°C |
| Operating Relative Humidity | <90% RH |
| Material | Anodized Aluminum Alloy |
| Stage Count | 6 |
| Aerodynamic Cut-Points (at 28.3 L/min) | Stage 1 ≥7.1 µm, Stage 2 4.7–7.1 µm, Stage 3 3.3–4.7 µm, Stage 4 2.1–3.3 µm, Stage 5 1.1–2.1 µm, Stage 6 0.65–1.1 µm |
| Dimensions (Impactor Only) | 133 mm Ø × 88.9 mm H |
| Weight (Impactor Only) | 2.75 kg |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Manufacturer | Tisch Environmental, Inc. |
| Model | TE-BC251 |
| Sampling Principle | Inertial Impaction via Multi-Stage Cyclonic Separation |
| Nominal Flow Rate | 3.5 L/min |
| Cut-Point Diameters (aerodynamic) | Stage 1: 4.9 µm, Stage 2: 1.7 µm, Stage 3: <0.4 µm |
| Compliance | Designed to NIOSH BC 251 Protocol |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TWA-300 |
| Pricing | Available Upon Request |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TWA-300HP |
| Pricing | Upon Request |
| Pump Pressure | >13,000 Pa |
| Flow Range | 20–500 mL/min |
| Flow Accuracy | ±5% FS |
| Flow Stability | ≤5% |
| Timer Accuracy | ≤±0.1% |
| Operating Temperature | −25 to +45 °C |
| Power Supply | AC 220 V ±10%, 50 Hz / Rechargeable Ni-MH Battery (≥12 h continuous operation) |
| Weight | ≤0.5 kg |
| Dimensions | 100 × 50 × 110 mm |
| Anti-Backflow Protection | Integrated liquid and particulate backflow prevention valve |
| Sampling Modes | Time-weighted average (TWA), short-term exposure limit (STEL), and fixed-duration programmable sampling |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | YP-QA |
| Price | USD 1,800 (FOB) |
| Sampling Principle | Six-Stage Andersen-style Impaction |
| Flow Rate | 28.3 L/min (±5% accuracy) |
| Particle Size Resolution | 0.65–7.0 µm across six tiers |
| Collection Efficiency | ≥98% |
| Timer Range | 1–99 h (±1% accuracy) |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC/DC dual-mode |
| Brand | Zefon |
|---|---|
| Origin | USA |
| Model | A6 |
| Sampling Principle | Impaction-based inertial separation |
| Flow Rate | 28.3 LPM (1 ACFM) |
| Cut-off Size | 0.65 µm |
| Dimensions | 4.25" diameter × 2.87" height |
| Weight | 1.23 lb |
| Material | Aerospace-grade aluminum alloy |
| Compliance | NIOSH Methods 0800 & 0801 |
| Sample Vessel | Standard 100 mm × 15 mm Petri dish |
| Brand | Zefon |
|---|---|
| Origin | USA |
| Model | Bio-Culture |
| Sampling Principle | Impaction-Based Active Air Sampling |
| Flow Range | 30–120 LPM |
| Timer Options | 1, 2, 5, and 10 minutes |
| Petri Dish Compatibility | Standard 90 mm × 15 mm |
| Nozzle Array | 380 × 1 mm diameter orifices |
| Battery Life | 6–8 hours (rechargeable) |
| Mounting | Integrated 1/4"-20 tripod thread |
| Sterilization | Autoclavable sampling head |
| Calibration Option | NIST-traceable venturi flow calibrator (±1% accuracy) |
| Brand | Zefon |
|---|---|
| Origin | USA |
| Model | Bio-Pump Plus |
| Sampling Principle | Active Impaction |
| Flow Rate | 15 LPM |
| Sampling Duration Range | 5 min – 8 h |
| Power Source | Rechargeable NiMH Battery |
| Dimensions (W×H×D) | 11.43 × 6.99 × 20.34 cm |
| Weight | 0.68 kg |
| Noise Level | Low-Noise Operation |
| Display | Real-Time Elapsed Time |
| Programmable Timer | Yes |
| Battery Runtime | Up to 8 h continuous or ~100 × 5-min samples |
| Charging Time | 3 h |
| Brand | Zefon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VIRA-PORE |
| Price Range | USD 1,400–2,800 (est.) |
| Sampling Principle | Active Impaction via High-Efficiency Porous Filter |
| Flow Rate | 10 L/min (for stationary sampling), 3 L/min (for personal sampling) |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | ZR-A03 |
| Pricing | Available Upon Request |
| Brand | Junray |
|---|---|
| Model | ZR-B02 |
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Pricing | Available Upon Request |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Junray Instrument Co., Ltd. |
| Type | ZR-G01 |
| Compatible Instruments | ZR-2050 & ZR-2050A Airborne Microbial Samplers |
| Pressure Regulation | Integrated pressure-reducing valve (max inlet pressure ≤ 1.0 MPa, output flow stabilized at 100 L/min ± 5%) |
| Material | Anodized aluminum adapter body |
| Connection | Pneumatic quick-coupling interface (ISO 8573-1 Class 2 compliant) |
| Design | Modular, field-deployable assembly |
| Compliance | Designed per Annex 1 (2022) of EU GMP and USP <797> requirements for compressed gas microbiological monitoring |