Air Microbial Sampler
Filter
Showing 31–60 of 80 results
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZR-2024 |
| Sampling Principle | Impaction-based Cyclonic Separation |
| Flow Rate Range | 50–300 L/min |
| Flow Measurement Accuracy | ±2.5% |
| Sampling Duration Range | 0–99 h 59 min |
| Operating Temperature | 0–50 °C |
| Operating Relative Humidity | 0–95% RH |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ZR-2052 |
| Sampling Principle | Impaction-Based Active Separation |
| Flow Rate Range | 100 L/min |
| Flow Measurement Accuracy | ±2.5% |
| Sampling Duration Range | 0–23 h 59 min 59 s |
| Operating Temperature | −20 to 50 °C |
| Operating Relative Humidity | 0–95% RH |
| Brand | Junray |
|---|---|
| Model | ZR-A01 |
| Material | Corrosion-Resistant Aluminum Alloy |
| Sampling Principle | Inertial Impaction |
| Stages | 2-stage cascade impactor configuration |
| Compliance | Designed to meet GB/T 18204.3–2013 (China National Standard for Air Microbial Detection) |
| Intended Use | Viable airborne microorganism collection on agar media |
| Brand | Junray |
|---|---|
| Model | ZR-A02 |
| Sampling Stages | 6-stage cascade impactor |
| Material | Corrosion-resistant aluminum alloy |
| Principle | Inertial impaction (Andersen-type) |
| Standard Compliance | ISO 14698-1, ISO 14698-2, USP <71>, EU GMP Annex 1 (airborne bioburden monitoring) |
| Sample Collection Medium | Standard Petri dishes with agar-based culture media |
| Flow Rate | Compatible with standard vacuum pumps (15–28.3 L/min typical for Andersen systems) |
| Cut-off Aerodynamic Diameters (Stage 1–6) | ~7.0, 4.7, 3.3, 2.1, 1.1, and 0.65 µm |
| Operating Temperature Range | 10–30 °C |
| Relative Humidity Limit | ≤80% RH (non-condensing) |
| Brand | Junray |
|---|---|
| Model | ZR-A05 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Sampling Principle | Inertial Impaction |
| Stages | 8-stage cascade impactor |
| Material | Corrosion-resistant aluminum alloy |
| Collection Media | Standard Petri dishes with agar-based culture media |
| Target Analytes | Viable airborne bacteria and fungi |
| Compliance | Meets GB/T 18204.1–2013 (Chinese National Standard for Microbiological Examination of Public Places), ISO 14698-1:2003 (Biocontamination control — Part 1: General principles and methods) |
| Brand | Junray |
|---|---|
| Model | ZR-B01 |
| Type | AGI-30 Impinger |
| Origin | Shandong, China |
| Manufacturer | Junray Instrument Co., Ltd. |
| Compliance | GB/T 18204.1–2013, HJ 93–2013, ISO 14698-1:2003 (principles) |
| Liquid Volume Capacity | 15–30 mL |
| Inlet Flow Rate Range | 5–15 L/min (optimized at 12.5 L/min) |
| Nozzle Orifice Diameter | 0.5 mm |
| Material | Borosilicate Glass (USP Type I), PTFE-sealed cap |
| Brand | Junray |
|---|---|
| Model | ZR-J03 |
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Compatible Instrument | ZR-2022 Intelligent Air Microbial Sampler |
| Pricing | Available Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | JWL-IIA |
| Pricing | Upon Request |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | JWL-IIB202 |
| Pricing | Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JWL-IIC |
| Pricing | Upon Request |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3080+ |
| Sampling Principle | Andersen Impaction |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Duration | 10 s to 1 h |
| Delay Time | 0 s to 23 h 59 min 59 s |
| Sampling Volume Range | 20–6000 L |
| Sampling Cycles | 2–300 or continuous |
| Operating Environment | 0–40 °C, 0–90% RH (non-condensing) |
| Sampling Head Material | 316 Stainless Steel |
| Exhaust Filter Class | ISO Class 3 |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery (7 h runtime) + AC adapter (100–240 V) |
| Dimensions | 136 × 235 × 133 mm |
| Weight | 3.2 kg |
| User Management | 64 editable users with multi-level permission control and audit trail |
| Language Support | English, Japanese, Chinese |
| Remote Control | Infrared (supports up to 5 units simultaneously) |
| Optional Accessories | Tripod, high-pressure gas sampling kit, thermal printer |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Accuracy | ±2.5% |
| Sampling Principle | Andersen Impaction (6-stage cascade impactor) |
| Impact Velocity | <20 m/s |
| Sampling Volume Range | 20–6000 L |
| Interval Time | 10 s–1 h |
| Delay Time | 0 s–23 h 59 min 59 s |
| Sampling Cycles | 2–300 or continuous |
| Petri Dish Compatibility | 90–100 mm and 55–84 mm |
| Exhaust Filter Class | ISO Class 3 |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV format) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power Supply | Li-ion rechargeable battery (7 h operation) + AC 100–240 V adapter |
| Operating Environment | 0–40 °C, 0–90% RH (non-condensing) |
| Weight | 3.2 kg |
| Dimensions | 136 × 235 × 133 mm |
| User Management | 64 editable users with multi-level permission control and audit trail |
| Remote Control | IR remote (supports up to 5 units simultaneously) |
| Language Support | English, Japanese, Chinese |
| Alarm | Visual & audible flow deviation alert |
| Materials | 316 stainless steel sampling head |
| Compliance | Designed for ISO 14698-1, ISO 14644-1/2, EU GMP Annex 1, USP <1116>, and FDA 21 CFR Part 11-ready data integrity architecture |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Volume Range | 20–6000 L |
| Sampling Duration | Up to 7 h (battery operation) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Principle | Andersen Impaction (6-stage cascade impactor) |
| Impact Velocity | <20 m/s |
| Exhaust Filtration | ISO Class 3 certified filter |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery + AC adapter (100–240 V) |
| Dimensions | 136 × 235 × 133 mm |
| Weight | 3.2 kg |
| Petri Dish Compatibility | 90–100 mm and 55–84 mm |
| User Management | 64 configurable users with multi-level permissions and audit trail |
| Remote Control | IR remote (supports up to 5 units simultaneously) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Volume Range | 20–6000 L |
| Sampling Time Range | Up to 7 h (battery operation) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Principle | Andersen Impaction (6-stage cascade impactor) |
| Impact Velocity | <20 m/s |
| Exhaust Filtration | ISO Class 3 HEPA filter integrated |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV format) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery + AC adapter (100–240 V) |
| Dimensions | 136 × 235 × 133 mm |
| Weight | 3.2 kg |
| Sample Support | 90–100 mm or 55–84 mm Petri dishes |
| User Management | 64 configurable users with multi-level permission control and audit trail |
| Remote Control | Infrared remote (supports up to 5 units simultaneously) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Sampling Principle | Andersen Impaction |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Battery Runtime | 7 h |
| Sampling Volume Range | 20–6000 L |
| Sampling Interval | 10 s–1 h |
| Delay Time | 0 s–23 h 59 min 59 s |
| Cycle Count | 2–300 cycles or continuous |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Display | 4.3-inch color touchscreen |
| Communication | USB, RS-485 (Modbus RTU) |
| User Management | 64 editable users with multi-level permission control and audit trail |
| Alarm | Visual & audible flow deviation alert |
| Exhaust Filtration | Integrated ISO Class 3 filter |
| Sampling Head Material | 316 stainless steel |
| Compatible Petri Dishes | 90–100 mm or 55–84 mm |
| Dimensions | 136 × 235 × 133 mm |
| Weight | 3.2 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Sampling Principle | Andersen Impaction |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Volume Range | 20–6000 L |
| Sampling Duration | Up to 7 h on battery |
| Display | 4.3-inch color touchscreen |
| Power | Rechargeable Li-ion battery + AC adapter (100–240 V) |
| Weight | 3.2 kg |
| Dimensions | 136 × 235 × 133 mm |
| Impactor Stages | 6-stage Andersen design |
| Impact Velocity | <20 m/s |
| Exhaust Filtration | ISO Class 3 HEPA filter |
| Culture Dish Compatibility | 90–100 mm and 55–84 mm Petri dishes |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| User Management | 64 editable users with multi-level permissions and audit trail |
| Remote Control | IR remote (supports up to 5 units simultaneously) |
| Language Support | English, Japanese, Chinese |
| Alarm System | Visual & audible alerts for flow deviation, low battery, door open, filter saturation |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Battery Runtime | 7 h |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS485 (Modbus RTU) |
| Sample Volume Range | 20–6000 L |
| Sampling Interval | 10 s–1 h |
| Delay Time | 0 s–23 h 59 min 59 s |
| Sampling Cycles | 2–300 or continuous |
| Petri Dish Compatibility | 90–100 mm and 55–84 mm |
| Exhaust Filter Class | ISO Class 3 |
| Power Supply | Li-ion rechargeable battery + AC adapter (100–240 V) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Battery Runtime | 7 h |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| Sample Volume Range | 20–6000 L |
| Sampling Interval | 10 s–1 h |
| Delay Time | 0 s–23 h 59 min 59 s |
| Sampling Cycles | 2–300 or continuous |
| Petri Dish Compatibility | 90–100 mm and 55–84 mm |
| Exhaust Filter Class | ISO Class 3 |
| Power Supply | Li-ion rechargeable battery + AC 100–240 V adapter |
| Dimensions | 136 × 235 × 133 mm |
| Weight | 3.2 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Duration | Up to 7 h (battery) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Volume Range | 20–6000 L |
| Time Interval Setting | 10 s–1 h |
| Delay Start | 0 s–23 h 59 min 59 s |
| Cycle Count | 2–300 cycles or continuous mode |
| Culture Dish Compatibility | 90–100 mm and 55–84 mm Petri dishes |
| Exhaust Filtration | ISO Class 3 |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery + AC adapter (100–240 V) |
| Weight | 3.2 kg |
| Dimensions | 136 × 235 × 133 mm |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Time Range | 10 s to 1 h |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Principle | Andersen Impaction |
| Impactor Stages | 6-stage |
| Impact Velocity | <20 m/s |
| Sample Volume Range | 20–6000 L |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery (7 h runtime) + AC adapter (100–240 V) |
| Weight | 3.2 kg |
| Dimensions | 136 × 235 × 133 mm |
| User Management | 64 editable users with multi-level permission control and audit trail |
| Alarm | Visual & audible flow anomaly alert |
| Exhaust Filtration | Integrated ISO Class 3 filter |
| Sampling Head Material | 316 stainless steel |
| Language Support | English, Japanese, Chinese |
| Optional Accessories | Tripod, high-pressure gas sampling kit, thermal printer |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Volume Range | 20–6000 L |
| Timing Range | 10 s to 1 h (delay: 0 s to 23 h 59 min 59 s) |
| Sampling Cycles | 2–300 or continuous |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Head Material | 316 Stainless Steel |
| Impactor Stages | 6-stage Andersen design |
| Impact Velocity | <20 m/s |
| Exhaust Filter Class | ISO Class 3 |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery (7 h runtime) + AC adapter (100–240 V) |
| Dimensions | 136 × 235 × 133 mm |
| Weight | 3.2 kg |
| Language Support | English, Japanese, Chinese |
| User Management | 64 editable users with multi-level permission and audit trail |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | M Air T Air Microbial Sampler |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Type | Imported Instrument |
| Model | MAC100ECO |
| Manufacturer Role | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MAS-100 NT |
| Sampling Principle | Impaction-based Active Air Sampling |
| Flow Rate Range | 1–2000 L/min |
| Flow Measurement Accuracy | ±2.5% at 100 L/min |
| Total Operating Time | Approx. 5.5 h on full battery charge |
| Storage Temperature | −10°C to +50°C |
| Operating Temperature | 0°C to +40°C |
| Operating Relative Humidity | ≤80% RH (up to +31°C), linearly decreasing to ≤50% RH at +40°C, non-condensing |
| Brand | Millipore |
|---|---|
| Origin | Switzerland |
| Model | MAS-100 CG Ex |
| Sampling Principle | Impaction-based Active Separation |
| Flow Rates | 50 L/min and 100 L/min (selectable, constant) |
| Flow Measurement Accuracy | ±0% to +10% at 50 L/min or 100 L/min over absolute pressure range of 1.5 bar to 10 bar |
| Total Operating Time | Approx. 3.5 h per battery charge |
| Ambient Temperature Range | 0–40°C |
| Ambient Relative Humidity | Up to 80% RH at ≤31°C, linearly decreasing to 50% RH at 40°C |
| Certifications | ATEX II 2G Ex db IIB T4 Gb / II 2D Ex tb IIIC T135°C Db (for use in Zone 1 & Zone 21 hazardous areas) |
| Brand | Millipore |
|---|---|
| Origin | Switzerland |
| Model | MAS-100 ECO |
| Sampling Principle | Impaction-based Active Air Sampling |
| Flow Range | 1–1000 L/min |
| Flow Accuracy | ±4% at 100 L/min |
| Total Operating Time | Approx. 3 hours |
| Operating Temperature | 0–40 °C |
| Operating Relative Humidity | 0–80% RH (non-condensing) |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TRIO.BAS DUO |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Sampling Principle | Isokinetic Impaction via Precision Laser-Drilled Stainless Steel Nozzle Array |
| Flow Rate | 200 L/min (selectable 100/200 L/min) |
| Flow Accuracy | ±2.5% of reading |
| Sampling Duration | 0–10 min (programmable in segments) |
| Operating Temperature | −10 °C to +40 °C |
| Operating Relative Humidity | 0–80 % RH |
| Sample Dish Compatibility | 60 mm and 90 mm Petri Dishes |
| Display | Backlit LCD (32 × 64 mm) |
| Control Interface | 4 Membrane Waterproof Keys |
| Wireless Connectivity | Integrated Bluetooth 5.0 |
| Power Supply | Rechargeable Ni-MH Battery (12 V, 4500 mAh) |
| Charging Input | AC 100–240 V, 50/60 Hz |
| USB Charging Port | 5 V, 500 mA |
| Weight | 1.9 kg (main unit only) |
| Dimensions | 260 × 280 × 140 mm |
| Certifications | CE (EN 61010-1:2010, EN 61326-1:2006, EN 62321:2009), ATEX II 2G Ex eb IIB T4 Gb (EN 60079-0:2012, IEC 60079-15:2010) |
| Data Integrity Compliance | FDA 21 CFR Part 11–ready audit trail & electronic signature support |
| Brand | PMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PMS MiniCapt |
| Flow Rate | 100 L/min |
| Flow Measurement Accuracy | ±1% of reading |
| Sampling Duration Range | 0–10 minutes |
| Operating Temperature Range | up to 45 °C |
| Operating Relative Humidity | up to 95% RH |
| Sampling Principle | Slit-to-Agar Impaction (ISO 14698-1 compliant) |
| Sterilization | Autoclavable BioCapt Impactor Head |
| Exhaust Filtration | Integrated HEPA (≥99.99% @ 0.3 µm) |
| Optional Accessories | Compressed Gas Kit, Isolator Sampling Kit |
| Compliance | Designed for ISO 14698-1, ISO 14644-1/2, EU GMP Annex 1, USP <1116>, FDA Aseptic Processing Guidance |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | 16757 |
| Flow Rates | 30, 40, 50, and 125 L/min (4 adjustable settings) |
| Flow Measurement Range | 1–16 m³/h, ±2% accuracy |
| Battery Runtime | ~4.5 hours at 50 L/min |
| Operating Temperature | Ambient |
| Operating Humidity | ≤85% RH (non-condensing) |
| Sampling Principle | Membrane filtration with gelatin or pre-filled Bactair™ agar media |
| Language Options | English, French, German, Italian, Spanish |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | 16746-01--COM |
| Sampling Principle | Gel Membrane Filtration |
| Flow Rate Range | 2.0–8.0 m³/h (adjustable) |
| Flow Measurement Accuracy | ±2% (1–16 m³/h) |
| Sampling Duration | 1–99 minutes (programmable), continuous monitoring mode up to 8 hours |
| Operating Temperature | Ambient |
| Operating Relative Humidity | ≤85% RH |
| Sterilization Compatibility | VHP (Vaporized Hydrogen Peroxide) resistant |
| Filter Pore Size | 0.2 µm |
| Microbial Retention Efficiency | ≥99.9% for bacteria and viruses |
| Maximum Cable Length Between Command Unit and Sampling Head | 30 m |