BrandMAIERIC
OriginAnhui, China
ModelMTIA
Instrument TypeMid-Frequency Impedance Analyzer
Frequency Range0.05 Hz – 10 MHz
Frequency Resolution0.05% of set frequency
Basic Measurement Accuracy±0.05%
Impedance Range20 mΩ – 1 GΩ
Measurement Speed10,000 samples/s
Measurement ModesFour-Terminal (Kelvin), Multi-Channel (up to 128 channels)
Excitation Voltage Range0.02 V – 2.0 V (10 mV resolution)
Compensation MethodsOpen-Short-Load, Open-Load, Short-Load, Load-only
Supported ParametersZ, θ, R, X, Ls/Lp, Cs/Cp, D, Q, Y, G, B
Equivalent Circuit ModelingYes
Data VisualizationSweep plots, multi-channel mapping, time-series traces
ComplianceDesigned for GLP-compliant lab environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAIERIC
ModelMTIA-A
Measurement Frequency Range0.05 Hz – 10 MHz
Basic Accuracy±0.05%
Impedance Range20 mΩ – 1 GΩ
Measurement SpeedUp to 10,000 samples/sec
Resolution0.05 Hz (frequency), 0.01 V (voltage)
Excitation Voltage Range0.02 V – 2 V
Measurement ModesFour-Terminal (Kelvin), Multi-Channel (up to 128 channels, 16 active simultaneously)
Impedance ParametersZ, R, X, L, C, D, Q, θ
Compensation MethodsOpen-Short-Load, Open-Load, Short-Load, Load-only
Analysis FeaturesEquivalent Circuit Modeling, Time-Domain Sequence Plotting, Multi-Channel Compensation, Sweep & Multi-Channel Mapping
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAIERIC
OriginAnhui, China
ModelCFT-1
Coercivity Range1–50 A/cm
Measurement DepthUp to 30 mm
Surface ClearanceUp to 6 mm
Measurement Speed~3.5 s per reading
Excitation Levels3 adjustable intensity settings
Data Storage32 GB internal (DB & CSV export)
Display2K full-touchscreen interface
ComplianceDesigned for field-deployable non-destructive evaluation (NDE) of ferromagnetic components
InterfaceUSB, HDMI, sensor port
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAIERIC
OriginAnhui, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelArray Eddy Current Testing Instrument
Inspection MethodAutomated Scanning
Eddy Current Signal TypeMulti-Frequency Eddy Current
Design Form FactorPortable
Number of ChannelsCustomizable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAIERIC
OriginAnhui, China
ModelDEMT-8/16
Detector TypeCustom Electromagnetic Sensor Array
Spatial Resolution5% of cross-sectional diameter
Density ResolutionConfigurable (system-dependent)
Penetration CapabilityCustomizable per application
Measurement RangeConfigurable (up to Ø300 mm cross-section)
Dimensional Accuracy±5% of cross-sectional dimension
Density Measurement AccuracyConfigurable
Operating TemperatureUp to 300 °C (non-contact probe interface)
Imaging ModesDual-mode (Eddy Current Tomography & Metal Flaw Detection)
Signal-to-Noise Ratio (SNR)60–90 dB
Frequency Range1 kHz–200 kHz (standard)
Channel Configuration8 or 16 independently configurable channels
Sampling RateUp to 100 kS/s per channel (flaw detection mode)
Reconstruction GridUp to 32×32 pixels (1% cross-sectional area resolution)
Front-End Signal ProcessingProgrammable 3-stage gain amplifier (1×–8×), with optional expansion
Data OutputComplex impedance components (real, imaginary, magnitude, phase), full complex-plane representation
Core PlatformFPGA-based digital acquisition and real-time processing architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAIERIC
ModelMBN-BH Grinding Burn Detector
Measurement PrincipleMagnetostrictive Barkhausen Noise (MBN) + Quasi-Static B-H Hysteresis Loop Analysis
Core ComponentsU-Core Excitation/Detection Probe with Integrated Hall Sensor & Miniature MBN Pickup Coil
Signal AcquisitionSimultaneous Real-Time MBN, B(t), and H(t) Waveforms
Data Output.db Binary Format with Timestamped Raw Signals
ConnectivityWi-Fi Enabled PC-Based Control Interface
Software FeaturesProgrammable Excitation Frequency/Amplitude, Adjustable MBN Bandpass Filter, Configurable Pre-Amplifier Gain, Dual-Axis Scalable XY Plotting (B vs. H, MBN vs. Time, H vs. Time)
Compliance ContextDesigned for GLP-aligned magnetic property evaluation per ASTM A342/A342M (Permeability), ISO 643 (Metallographic Hardness Correlation), and internal QC protocols for aerospace & automotive component manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAIERIC
OriginAnhui, China
ModelTEST
Measurement PrincipleElectromagnetic Induction + Hall Effect + High-Frequency Eddy Current Coupling
Core FunctionsSimultaneous MBN Signal Acquisition, Quasi-Static BH Loop Tracing, Coercivity & Remanence Calculation
ConnectivityWi-Fi (IEEE 802.11 b/g/n), USB 2.0
Signal BandwidthMBN Channel: 50 kHz – 1.2 MHz (programmable bandpass filter), B/H Channels: DC – 10 kHz
Data Output FormatSQLite .db (timestamped raw MBN, B, H waveforms + calculated hysteresis parameters)
Software InterfaceWindows-based GUI with real-time XY scaling, parameter sweep capability, and export to CSV/MAT
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAIERIC
OriginAnhui, China
ModelMBN-2000
Measurement PrincipleElectromagnetic Induction + Hall Effect + High-Frequency Eddy Current Coupling
Signal Bandwidth10 kHz – 2 MHz (programmable bandpass)
MBN Preamp Gain20–80 dB (software-adjustable)
Excitation Frequency Range1 Hz – 1 kHz
Excitation Voltage Amplitude0–20 Vpp (programmable)
Data Storage FormatSQLite (.db) with timestamped raw MBN, B, and H waveforms
Real-time DisplayDual-axis XY plot (H vs. B, MBN envelope vs. H) with scalable axes
ConnectivityIEEE 802.11n Wi-Fi (2.4 GHz), USB 2.0 fallback
ComplianceDesigned per IEC 60404-6 (magnetic measurement methods), compatible with ASTM A932/A932M (standard test method for Barkhausen noise evaluation of ferromagnetic materials)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAIERIC
OriginAnhui, China
ModelMTIA-8
Instrument TypeMedium-Frequency Impedance Analyzer
Frequency Range0.01 Hz – 10 MHz
Frequency Resolution0.05 Hz
Basic Measurement Accuracy±0.05%
Impedance Range20 mΩ – 1 GΩ
Measurement Speed10,000 samples per second
Channel CapacityUp to 128 parallel measurement channels (hardware-expandable)
Measurement ModesFour-Terminal (Kelvin), Multi-Channel Synchronized Acquisition
Excitation Voltage Range0.02 V – 2.0 V (10 mV resolution)
Compensation MethodsOpen-Short-Load, Open-Load, Short-Load, Load-only
Supported ParametersZ, θ, R, X, Ls/Lp, Cs/Cp, D, Q, Y, G, B, Rs, Rp
Equivalent Circuit FittingUp to 7-element models (e.g., R-C, R-L-C, R-(C//R), etc.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAIERIC
OriginAnhui, China
ModelBH Hysteresis Loop & Barkhausen Noise Analyzer
Measurement PrincipleDual-mode electromagnetic induction + Hall-effect field sensing + high-frequency MBN detection
Excitation Frequency Range1 Hz – 1 kHz (programmable)
Signal AcquisitionSimultaneous B (flux density), H (magnetic field strength), and MBN (Barkhausen noise) waveforms
Data Output Format.db (binary database with timestamped raw channels)
Real-time DisplayAdjustable XY scaling for B–H loop, H(t), MBN envelope, and time-domain MBN burst trains
ConnectivityWi-Fi 802.11n (IEEE 802.11 compliant), USB 2.0 backup
FilteringProgrammable bandpass filter (10 kHz – 1 MHz, 3rd-order IIR) for MBN
AmplificationProgrammable preamplifier gain (20 dB – 60 dB, 10 dB steps)
ComplianceDesigned per IEC 60404-4 (magnetic materials — methods of measurement of DC magnetic properties) and ASTM A341/A341M (standard test method for direct-current magnetic properties of materials)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAIERIC
OriginAnhui, China
ModelMAIERIC
Measurement PrincipleCombined DC-biased hysteresis loop tracing + high-frequency Barkhausen noise detection
Signal AcquisitionDual-channel synchronized B–H and MBN waveform capture
Excitation Frequency Range0.1–100 Hz (programmable)
MBN Bandwidth20 kHz–1 MHz (programmable bandpass filter)
Data Output Format.db (binary database with timestamped MBN, B, H waveforms)
InterfaceWi-Fi-enabled real-time PC control
ComplianceDesigned for ASTM E1444/E2884-compliant magnetic testing workflows
Software FeaturesReal-time x–y scalable plotting of B(H), H(t), and MBN(t)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAIERIC
OriginAnhui, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelCFT-Series
PricingUpon Request
Excitation Levels3 Adjustable Steps
Lift-off ToleranceUp to 6 mm
Measurement Speed3.5 s per reading
Penetration Depth30 mm
Coercivity Range1–50 A/cm
Display2K Full-Touch LCD
Storage Capacity32 GB (DB + CSV export)
Measurement ModesManual Keypad / Continuous Auto-Scan
CalibrationIntelligent Auto-Calibration Routine
ImagingBuilt-in 1D/2D Mapping Visualization
Data ExportStandard DB & CSV formats
ComplianceDesigned for ASTM E1444/E709-compliant magnetic particle inspection workflows and ISO 10893-1 non-destructive testing requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAIERIC
OriginAnhui, China
ModelBH-MBN-1000
Measurement PrincipleDual-mode electromagnetic induction + Hall-effect field sensing + high-sensitivity MBN coil detection
Excitation Frequency Range1 Hz – 10 kHz (programmable)
MBN Bandpass Filter20 kHz – 2 MHz (adjustable center frequency & bandwidth)
Signal AcquisitionSimultaneous real-time sampling of B (flux density), H (magnetic field strength), and MBN voltage waveform
Data Output FormatSQLite (.db) with timestamped raw channels, calculated coercivity (Hc), remanence (Br), and MBN RMS/peak amplitude
InterfaceWi-Fi 802.11n (IEEE 802.11 compliant), USB 2.0 fallback
Software PlatformWindows 10/11 native application with GLP-compliant audit trail logging (user action timestamps, parameter change history, export metadata)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAIERIC
OriginAnhui, China
ModelPECT-1 PULSED EDDY CURRENT
DesignPortable
Inspection MethodPulsed Eddy Current (PEC)
Signal TypeTransient Electromagnetic Response
Measurement IntegrationEncoder-based Position Tracking
Lift-off ToleranceUp to 160 mm
Wall Thickness Range1–30 mm
Non-ferromagnetic Cladding PenetrationUp to 2 mm
Cladding Thickness Variation Compensation±50% with ≤±2% measurement deviation
Imaging ModeUser-configurable 2D grid mapping with real-time coordinate registration
ComplianceDesigned for ASTM E2884-23 (Standard Guide for Pulsed Eddy Current Examination), ISO 12718:2019 (Non-destructive testing — Vocabulary — Eddy current testing), and GLP-aligned data integrity workflows