| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | A390 |
| Price Range | USD 4,200–7,000 (FOB Shanghai) |
| Optical Design | Single-Beam with Dual-Beam Ratio Monitoring |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5, 1.0, 2.0, 4.0, 5.0 nm |
| Stray Light | ≤0.03% T at 360 nm |
| Display | 6.5K-color TFT LCD (800 × 480) |
| Data Storage | 240 calibration curves (240 data points each) onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.1 host port for firmware update |
| Software | AOE Basic Spectroscopy Suite (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001:2015, CE (2014/30/EU & 2011/65/EU), CMC License (PRC Metrology Certification), RoHS Directive 2011/65/EU |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | U120Pro |
| Price Range | USD 1,400–2,800 |
| Optical Design | Single-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 195–1100 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.0 nm |
| Stray Light | ≤0.1% T at 220 nm and 340 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Baseline Stability | ±0.001 Abs/h at 500 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | T5 |
| Price Range | USD 1,400–2,800 |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Automatic |
| Spectral Bandwidth | 4.0 nm (±3.8 nm) |
| Wavelength Accuracy | ±0.4 nm (±0.3 nm at 546.1 nm) |
| Stray Light | ≤0.04% T (at 220 nm and 360 nm) |
| Wavelength Repeatability | ≤0.2 nm |
| Photometric Noise | ±0.0005 Abs (0–0.5 Abs), ±0.0004 Abs (0.5–1.0 Abs) |
| Display | 7-inch TFT LCD Touchscreen (1024 × 800 resolution) |
| Data Export | USB flash drive interface |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Sample Handling | Standard 6-position automatic cuvette changer (1–5 cm pathlength support) |
| Software Compliance | Audit trail enabled, 21 CFR Part 11–ready configuration options |
| Maintenance | Lifetime free firmware and software updates |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | A590 |
| Optical System | Dual-Beam Ratio-Monitoring |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm |
| Stray Light | ≤0.02% T @ 360 nm |
| Display | 800 × 480 TFT color LCD (65K colors) |
| Data Storage | 240 curves × 240 data points onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.0 for PC connectivity |
| Software | AOE Basic Spectroscopy Suite (certified under PRC Software Copyright Registration) |
| Compliance | ISO 9001, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | A580 |
| Optical System | Dual-beam ratio-monitoring |
| Detector Type | Silicon photodiode |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.0 nm |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | ≤0.02% T @ 360 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Display | 800 × 480 pixel, 65K-color TFT LCD |
| Data Storage | 240 curves (240 data points each) onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.0 for PC connectivity |
| Software | AOE Basic Spectroscopy Software (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | U110Pro |
| Price Range | USD 700–1,400 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 200–1100 nm |
| Wavelength Scanning Mode | Motorized Auto-Scan |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.5 nm |
| Stray Light | ≤0.1% T at 220 nm and 340 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Baseline Stability | ±0.001 Abs/h at 500 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FP640 |
| Price Range | USD 720–1,430 (FOB Shanghai) |
| Stability (15 s) | ≤3% RSD |
| Stability (6 min, 1-min interval) | ≤15% RSD |
| Repeatability | ≤3% RSD |
| Linearity Error | K: ≤0.005 mmol/L (0.0100–0.0800 mmol/L) |
| Na | ≤0.03 mmol/L (0.0500–0.400 mmol/L) |
| Detection Limit | K: ≤0.004 mmol/L |
| Na | ≤0.008 mmol/L |
| K Interference Filter | Peak Wavelength Tolerance ≤±7 nm |
| Na Interference Filter | Peak Wavelength Tolerance ≤±5 nm |
| Filter Bandwidth (FWHM) | ≤15 nm for both K and Na filters |
| Background Transmittance | ≤0.5% |
| Response Time | <8 s |
| Sample Aspiration Rate | <6 mL/min |
| Display | LCD with integrated parameter readout |
| Optical System | Fixed-wavelength interference filters |
| Detector | Silicon photodiode |
| Measurement Range (as elemental concentration) | K: 0–100 µg/mL |
| Na | 0–160 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–100 µg/mL |
| Ba | 0–3000 µg/mL |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | V120Pro |
| Price Range | USD 700–1,400 (FOB) |
| Optical System | Single-Beam with Holographic Grating (1200 lines/mm) |
| Detector | Silicon Photocell |
| Wavelength Range | 320–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 4.0 nm |
| Stray Light | ≤0.1%T at 220 nm and 360 nm |
| Baseline Stability | ±0.001 A/h at 500 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Display | 7-inch TFT LCD Touchscreen |
| Data Output | USB 2.0, RS-232, Optional PC Software |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | A360 |
| Price Range | USD 4,200 – 7,000 |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | ≤0.03% T @ 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | X-200 / X200S / X-201 |
| Optical System | Pseudo-Double-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | 1.0 nm (X-200), 1.8 nm (X-201), 1.0/2.0/3.0/5.0 nm (X200S) |
| Stray Light | ≤0.01%T @ 220 nm & 360 nm |
| Photometric Accuracy | ±0.2%T |
| Photometric Repeatability | ≤0.08%T |
| Baseline Flatness | ±0.0005 Abs |
| Drift | 0.0004 Abs/h @ 500 nm |
| Noise | ±0.00008 Abs |
| Wavelength Scanning Speed | 31,800 nm/min |
| Data Point Resolution | 0.1–10 nm (selectable) |
| Display | 8-inch backlit capacitive touchscreen LCD |
| Operating System | WinCE 6.6 |
| Sample Holder | Standard automatic 6-cell rotating cuvette changer |
| Interface | USB, Ethernet, RS-232, Printer port |
| Connectivity | Wired LAN & optional Wi-Fi module |
| Firmware Update | USB-based one-click upgrade via instrument serial number |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T2 |
| Price Range | USD 1,400–2,800 |
| Optical Configuration | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 195–1020 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | ±3.8 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.1%T (at 220 nm and 360 nm) |
| Noise Level | ±0.001 Abs |
| Brand | AOE |
|---|---|
| Model | OD600 |
| Instrument Type | Benchtop Microbial Turbidimeter |
| Detection Wavelength | 600 nm ± 1 nm |
| Bandwidth | 10 nm |
| Absorbance Range | −0.3 to 3.0 Abs |
| Absorbance Accuracy | ±0.005 Abs (0–0.5 Abs), ±0.01 Abs (0.5–1.0 Abs) |
| Absorbance Repeatability | ≤0.002 Abs |
| Light Source | High-Stability Solid-State LED (20,000 h lifetime) |
| Detector | Silicon Photodiode |
| Sample Volume | 200–3000 µL |
| Display | 8-inch HD Color TFT LCD (1024 × 600) |
| Data Storage | 128 MB internal memory |
| Data Export | USB flash drive & microSD card support |
| Built-in Thermal Printer | Yes (auto/batch print) |
| Power Supply | AC 100–240 V, 50/60 Hz or DC 12 V / 3 A |
| Dimensions (W × D × H) | 290 × 260 × 100 mm |
| Weight | 2.15 kg |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | V-1000 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 325–1020 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.5 nm |
| Stray Light | ≤0.1% T |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | WA755 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Colorimetric Method (with Predefined Reagent-Based Reaction Chemistry) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Photometric Accuracy (Transmittance) | <0.5% T |
| Photometric Repeatability | <0.2% T |
| Stray Light | <0.05% T |
| Optical Stability | ±0.002 A/h |
| Display | 65K-color TFT LCD |
| Interface | USB Data Export |
| Measured Parameters | COD, Ammonia Nitrogen (NH₃-N), Total Nitrogen (TN), Total Phosphorus (TP) |
| Measurement Ranges | COD: 0.02–100 mg/L |
| NH₃-N | 0.01–30 mg/L |
| TN | 2–15,000 mg/L |
| TP | 1–10 mg/L |
| Detection Limits | NH₃-N: 0.01 mg/L |
| COD | 0.02 mg/L |
| TN | 2 mg/L |
| TP | 1 mg/L |
| Measurement Time per Parameter | NH₃-N: 15 min |
| TP | 40 min |
| TN | 50 min |
| COD | 20 min |
| Batch Capacity | 16 samples (COD/TN/TP) |
| Digestion Temperature Control | COD: 165 °C ±0.5 °C |
| TN | 122 °C ±0.5 °C |
| TP | 120 °C ±0.5 °C |
| NH₃-N | adjustable (sealed or open-mode) |
| Digestion Duration | COD/TN/TP/NH₃-N: 10–40 min (parameter-specific) |
| Digestion Mode | Sealed (TN, TP), Sealed or Open (NH₃-N, COD) |
| Calibration Curve Storage | 200 preloaded & user-defined curves |
| Data Storage Capacity | 40,000 test records |
| Compliant Standards | GB/T 11893–1989 (TP), GB/T 11894–1989 (TN), HJ 535–2009 (NH₃-N), HJ 399–2007 (COD) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | UV-1800PC |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Automatic |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.4 nm |
| Stray Light | ≤0.04% T at 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T1 |
| Instrument Architecture | Single-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 200–1020 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.1% T (at 220 nm and 360 nm) |
| Absorbance Noise | ±0.001 Abs |
| Display | 7-inch TFT LCD Touchscreen (480 × 272 pixels) |
| Data Export | USB flash drive interface |
| Software Features | Audit Trail, GMP/GLP-compliant data logging, lifetime free firmware & software updates |
| Sample Holder Compatibility | Adjustable cuvette holder for 1–5 cm pathlength cells |
| Optical System | Holographic grating (1200 lines/mm) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | A560 |
| Optical System | Dual-beam ratio-monitoring |
| Detector Type | Silicon photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.02% T at 360 nm |
| Wavelength Scanning | Automatic |
| Display | 800 × 480 pixel, 65K-color TFT LCD |
| Data Storage | 240 curves (240 data points each) onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.0 for PC connectivity |
| Software | AOE Basic Spectroscopy Software (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | WA655 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | UV-Vis Absorption Spectrophotometry |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Photometric Accuracy | <0.5% T |
| Photometric Repeatability | <0.2% T |
| Stray Light | <0.05% T |
| Optical Stability | ±0.002 A/h |
| Detection Limits | TN: 0.1 mg/L, TP: 0.05 mg/L, NH₃-N: 0.01 mg/L, COD: 0.02 mg/L |
| Measurement Ranges | TN: 2–15,000 mg/L, TP: 1–10 mg/L, NH₃-N: 0.01–30 mg/L, COD: 0.02–100 mg/L |
| Measurement Error | TN < ±8%, TP < ±5%, NH₃-N < ±5%, COD < ±5% |
| Digestion Temperature Control | TN: 122 °C ±0.5 °C, TP: 120 °C ±0.5 °C, COD: 165 °C ±0.5 °C |
| Digestion Time | TN: 40 min, TP: 30 min, NH₃-N: 10 min, COD: 10 min |
| Digestion Mode | Sealed (TN, TP), Sealed or Open (NH₃-N, COD) |
| Sample Throughput | 16 samples per batch (TN/TP/COD), 20 samples per batch (NH₃-N), expandable |
| Display | 65K-color TFT LCD |
| Interface | USB |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | V-1300 |
| Power Supply | Rechargeable Li-ion battery (16–24 V), AC adapter & USB power input supported |
| Operating Time | 3–4 h (standard 10,000 mAh battery) |
| Wavelength Range | 325–1020 nm |
| Light Source | Tungsten-halogen lamp |
| Stray Light | ≤0.1% T at 340 nm (NaNO₂) |
| Photometric Stability | ±0.002 A |
| Display | 128 × 64 dot-matrix LCD |
| Measurement Modes | Absorbance (A), Transmittance (T), Concentration (C), Factor (F) |
| Sample Holder | Single-cuvette compartment (10 mm pathlength) |
| Interface | USB 1.0 (PC connectivity & software control) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ND500 |
| Price Range | USD 9,500 – 13,600 (FOB Shanghai) |
| Optical Design | Single-Beam |
| Detector | 2048-Pixel Linear CCD Array |
| Wavelength Range | 185–910 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.1% T at 220 nm and 340 nm |
| Photometric Accuracy | ±0.002 Abs (at 1 mm pathlength) |
| Minimum Sample Volume | 0.5 µL |
| dsDNA Detection Range | 2–15,000 ng/µL |
| Scan Speed | <0.5 s per full spectrum |
| Spectral Resolution | ≤1.8 nm FWHM (measured at Hg 253.7 nm line) |
| Light Source | Pulsed Xenon Lamp |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n |
| Software Update | USB Flash Drive–Based Firmware Upgrade (Lifetime Free) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | V-1800 |
| Price Range | USD 1,400–2,800 (FOB) |
| Optical System | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.4 nm |
| Stray Light | ≤0.04% T @ 220 nm & 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | WA650 |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Photometric Accuracy (Transmittance) | <0.5% T |
| Photometric Repeatability (Transmittance) | <0.2% T |
| Stray Light | <0.05% T |
| Optical Stability | ±0.002 A/h |
| Measured Parameters | Total Nitrogen (TN), Total Phosphorus (TP), Ammonia-Nitrogen (NH₃-N), Chemical Oxygen Demand (COD) |
| Measurement Ranges | TN: 2–15,000 mg/L |
| TP | 1–10 mg/L |
| NH₃-N | 0.01–30 mg/L |
| COD | 0.02–100 mg/L |
| Measurement Time | TN: 50 min |
| TP | 40 min |
| NH₃-N | 15 min |
| COD | 20 min |
| Measurement Error | TN: <±8% |
| TP | <±5% |
| NH₃-N | <±5% |
| COD | <±5% |
| Batch Capacity | TN/TP/COD: up to 16 samples (expandable) |
| NH₃-N | up to 20 samples (expandable) |
| Digestion Temperature Control | TN: 122°C ±0.5°C |
| TP | 120°C ±0.5°C |
| COD | 165°C ±0.5°C |
| Digestion Time | TN: 40 min |
| TP | 30 min |
| NH₃-N | 10 min |
| COD | 10 min |
| Digestion Mode | Sealed for TN & TP |
| Preloaded Calibration Curves | 200 sets |
| Data Storage Capacity | 40,000 test records |
| Standard Accessories | Reagent kits, 16-position intelligent digester, optional cuvettes (1 cm / 2 cm / 3 cm) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | V-1800PC |
| Price Range | USD 1,400–2,800 |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.4 nm |
| Stray Light | ≤0.04% T @ 360 nm and 600 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | V-1200 |
| Price Range | USD 1,400–2,800 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1020 nm |
| Wavelength Scanning | Motorized Auto-Scan |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.0 nm |
| Stray Light | ≤0.1% T @ 360 nm |
| Display | 128 × 64 Dot-Matrix LCD |
| Data Output | USB Port (U-disk export), RS-232 Serial Print Interface |
| Software | AOE Basic Spectroscopy Suite (Certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001:2015, CE, CMC (China Metrology Certification), RoHS Directive 2011/65/EU |