Empowering Scientific Discovery

Aoyi Instrument (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAOE
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelFP640
Price RangeUSD 720–1,430 (FOB Shanghai)
Stability (15 s)≤3% RSD
Stability (6 min, 1-min interval)≤15% RSD
Repeatability≤3% RSD
Linearity ErrorK: ≤0.005 mmol/L (0.0100–0.0800 mmol/L)
Na≤0.03 mmol/L (0.0500–0.400 mmol/L)
Detection LimitK: ≤0.004 mmol/L
Na≤0.008 mmol/L
K Interference FilterPeak Wavelength Tolerance ≤±7 nm
Na Interference FilterPeak Wavelength Tolerance ≤±5 nm
Filter Bandwidth (FWHM)≤15 nm for both K and Na filters
Background Transmittance≤0.5%
Response Time<8 s
Sample Aspiration Rate<6 mL/min
DisplayLCD with integrated parameter readout
Optical SystemFixed-wavelength interference filters
DetectorSilicon photodiode
Measurement Range (as elemental concentration)K: 0–100 µg/mL
Na0–160 µg/mL
Li0–100 µg/mL
Ca0–100 µg/mL
Ba0–3000 µg/mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAOE
Model6400A
OriginShanghai, China
TypeBenchtop Flame Emission Spectrometer
Detection ElementsK, Na, Li, Ca, Ba
Optical SystemInterference Filter-Based Monochromator
DetectorSilicon Photocell
DisplayLCD
Sample Uptake Rate<6 mL/min
Response Time<8 s
Stability (15 s)≤3% RSD
Stability (6 min, 6 readings)≤15% RSD
Repeatability≤3% RSD
Linearity ErrorK: ≤0.005 mmol/L (0.0100–0.0800 mmol/L)
Na≤0.03 mmol/L (0.0500–0.400 mmol/L)
Detection LimitK: ≤0.004 mmol/L
Na≤0.008 mmol/L
Potassium FilterPeak Wavelength Tolerance ≤±7 nm, FWHM ≤15 nm, Background Transmittance ≤0.5%
Sodium FilterPeak Wavelength Tolerance ≤±5 nm, FWHM ≤15 nm, Background Transmittance ≤0.5%
Measurement RangeK: 0–100 µg/mL
Na0–160 µg/mL
Li0–100 µg/mL
Ca0–100 µg/mL
Ba0–3000 µg/mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAOE
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelFP6410
Price RangeUSD 1,400–2,800
Stability (15 s)≤3% RSD
Stability (6 min, 1-min interval)≤15% RSD
Repeatability≤3% RSD
Linearity ErrorK ≤0.005 mmol/L (0.0100–0.0800 mmol/L)
Detection LimitK ≤0.004 mmol/L
Filter Peak Wavelength ToleranceK ≤7 nm
Filter Bandwidth (FWHM)≤15 nm (K & Na)
Filter Background Transmittance≤0.5%
Response Time<8 s
Sample Aspiration Rate<6 mL/min
DisplayLCD
Optical FilteringInterference Filters
PhotodetectorSilicon Photocell
Measurement RangeK: 0–100 µg/mL
Na0–160 µg/mL
Li0–100 µg/mL
Ca0–100 µg/mL
Ba0–3000 µg/mL