Aoyi Instrument (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAOE
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelWA755
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleColorimetric Method (with Predefined Reagent-Based Reaction Chemistry)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.5 nm
Photometric Accuracy (Transmittance)<0.5% T
Photometric Repeatability<0.2% T
Stray Light<0.05% T
Optical Stability±0.002 A/h
Display65K-color TFT LCD
InterfaceUSB Data Export
Measured ParametersCOD, Ammonia Nitrogen (NH₃-N), Total Nitrogen (TN), Total Phosphorus (TP)
Measurement RangesCOD: 0.02–100 mg/L
NH₃-N0.01–30 mg/L
TN2–15,000 mg/L
TP1–10 mg/L
Detection LimitsNH₃-N: 0.01 mg/L
COD0.02 mg/L
TN2 mg/L
TP1 mg/L
Measurement Time per ParameterNH₃-N: 15 min
TP40 min
TN50 min
COD20 min
Batch Capacity16 samples (COD/TN/TP)
Digestion Temperature ControlCOD: 165 °C ±0.5 °C
TN122 °C ±0.5 °C
TP120 °C ±0.5 °C
NH₃-Nadjustable (sealed or open-mode)
Digestion DurationCOD/TN/TP/NH₃-N: 10–40 min (parameter-specific)
Digestion ModeSealed (TN, TP), Sealed or Open (NH₃-N, COD)
Calibration Curve Storage200 preloaded & user-defined curves
Data Storage Capacity40,000 test records
Compliant StandardsGB/T 11893–1989 (TP), GB/T 11894–1989 (TN), HJ 535–2009 (NH₃-N), HJ 399–2007 (COD)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAOE
OriginShanghai, China
ModelWA655
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleUV-Vis Absorption Spectrophotometry
Wavelength Range190–1100 nm
Wavelength Accuracy±0.5 nm
Photometric Accuracy<0.5% T
Photometric Repeatability<0.2% T
Stray Light<0.05% T
Optical Stability±0.002 A/h
Detection LimitsTN: 0.1 mg/L, TP: 0.05 mg/L, NH₃-N: 0.01 mg/L, COD: 0.02 mg/L
Measurement RangesTN: 2–15,000 mg/L, TP: 1–10 mg/L, NH₃-N: 0.01–30 mg/L, COD: 0.02–100 mg/L
Measurement ErrorTN < ±8%, TP < ±5%, NH₃-N < ±5%, COD < ±5%
Digestion Temperature ControlTN: 122 °C ±0.5 °C, TP: 120 °C ±0.5 °C, COD: 165 °C ±0.5 °C
Digestion TimeTN: 40 min, TP: 30 min, NH₃-N: 10 min, COD: 10 min
Digestion ModeSealed (TN, TP), Sealed or Open (NH₃-N, COD)
Sample Throughput16 samples per batch (TN/TP/COD), 20 samples per batch (NH₃-N), expandable
Display65K-color TFT LCD
InterfaceUSB
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAOE
OriginShanghai, China
ModelWA650
Wavelength Range190–1100 nm
Wavelength Accuracy±0.5 nm
Photometric Accuracy (Transmittance)<0.5% T
Photometric Repeatability (Transmittance)<0.2% T
Stray Light<0.05% T
Optical Stability±0.002 A/h
Measured ParametersTotal Nitrogen (TN), Total Phosphorus (TP), Ammonia-Nitrogen (NH₃-N), Chemical Oxygen Demand (COD)
Measurement RangesTN: 2–15,000 mg/L
TP1–10 mg/L
NH₃-N0.01–30 mg/L
COD0.02–100 mg/L
Measurement TimeTN: 50 min
TP40 min
NH₃-N15 min
COD20 min
Measurement ErrorTN: <±8%
TP<±5%
NH₃-N<±5%
COD<±5%
Batch CapacityTN/TP/COD: up to 16 samples (expandable)
NH₃-Nup to 20 samples (expandable)
Digestion Temperature ControlTN: 122°C ±0.5°C
TP120°C ±0.5°C
COD165°C ±0.5°C
Digestion TimeTN: 40 min
TP30 min
NH₃-N10 min
COD10 min
Digestion ModeSealed for TN & TP
Preloaded Calibration Curves200 sets
Data Storage Capacity40,000 test records
Standard AccessoriesReagent kits, 16-position intelligent digester, optional cuvettes (1 cm / 2 cm / 3 cm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAOE
OriginShanghai, China
ModelWA653
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleUV-Vis Spectrophotometry (with Integrated Digestion)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.5 nm
Photometric Accuracy (Transmittance)< ±0.5% T
Photometric Repeatability< ±0.2% T
Stray Light< 0.05% T
Optical Stability±0.002 A/h
Detection Limit0.01 mg/L (for TN, TP, NH₃-N, COD)
Resolution0.001 mg/L
Measurement RangeTotal Nitrogen (TN): 2–15,000 mg/L
Total Phosphorus (TP)1–10 mg/L
Ammonia Nitrogen (NH₃-N)0.01–30 mg/L
Chemical Oxygen Demand (COD)0.02–100 mg/L
Measurement ErrorTN < ±8%, TP < ±5%, NH₃-N < ±5%, COD < ±5%
Digestion Temperature ControlTN: 122 °C ±0.5 °C
TP120 °C ±0.5 °C
COD165 °C ±0.5 °C
Digestion TimeTN: 40 min
TP30 min
NH₃-N10 min
COD10 min
Sample ThroughputUp to 16 samples (TN/TP/COD), up to 20 samples (NH₃-N), with optional expansion
Display65K-color TFT LCD
Data Storage40,000 measurement records + 200 preloaded calibration curves
InterfaceUSB