- All
- Favorite
- Popular
- Most rated
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | MET ONE 7000 |
| Instrument Type | Optical Airborne Particle Counter |
| Flow Rate Options | 0.1 CFM or 1.0 CFM |
| Particle Size Sensitivity | 0.5 µm |
| Channel Configurations | 2-channel or 4-channel selectable |
| Light Source | Long-life laser diode |
| Housing Material | Electropolished stainless steel, VHP-resistant optics |
| Compliance | ISO 21501-4, ISO 14644-1/2, IEST-RP-CC021.1, FDA 21 CFR Part 11 (with optional audit trail software), GMP-environment validated design |
| Operating Temperature | 10–32 °C |
| Relative Humidity | 5–95% RH (non-condensing) |
| Power Supply | 24 VDC ±10% or 100–230 VAC, 50/60 Hz |
| Max Power Consumption | 6.9 W (Ethernet DC), 12.5 W (Wireless AC) |
| Vacuum Requirement | ≥40.6 cm Hg |
| Flow Control | Precision orifice-based |
| Counting Loss | ≤5% at 2×10⁶ particles/ft³ (7005 variant) or 4×10⁵ particles/ft³ (7015 variant) |
| False Count Rate | ≤1 particle per 5 minutes |
| Communication Interfaces | Ethernet TCP/IP, RS-485 Modbus RTU/FXB, 4–20 mA analog output, wireless (optional) |
| Enclosure Rating | NEMA 4X |
| Weight | 3.73 kg (AC), 3.67 kg (DC) |
| Dimensions | 22.9 W × 12.5 D × 16.0 H cm |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Optical Airborne Particle Counter System |
| Model | MET ONE FMS |
| Instrument Category | Optical Particle Counter |
| Compliance | ISO 14644-1, ISO 21501-4, FDA 21 CFR Part 11, EU GMP Annex 1 |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HIAC 9703+ |
| Instrument Type | Optical Liquid Particle Counter |
| Sample Volume Range | 1 mL to 1000 mL |
| Particle Size Detection Range | 0.5 µm to 600 µm |
| Regulatory Compliance | FDA 21 CFR Part 11, ISO 21501-4 |
| Preconfigured Pharmacopoeial Methods | USP <788>, USP <789>, EP 2.9.19, JP 6.07, KP 5.2.10 |
| Software | PharmSpec v5.x with Audit Trail, Electronic Signatures, and Automated Backup/Restore |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LS 13 320 XR |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 10 nm – 3500 µm |
| Repeatability | < ±0.5% |
| Measurement Time | 10 seconds |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MET ONE R4800/R4900 |
| Instrument Type | Optical Particle Counter |
| Minimum Detectable Size | 0.3 µm (R4803/R4903) or 0.5 µm (R4805/R4815/R4905/R4915) |
| Flow Rate | 0.1 CFM (2.83 L/min) or 1.0 CFM (28.3 L/min) |
| Detection Principle | Laser Diode-Based Light Scattering |
| Channel Configuration | Dual-channel (e.g., 0.3/0.5 µm or 0.5/5.0 µm) |
| Counting Efficiency Loss | <5% at 2×10⁶ particles/ft³ |
| Operating Temperature | 12–41°C |
| Relative Humidity | 20–95% RH (non-condensing) |
| Power Interface | Open-collector FET output (max. 150 mA sink, 30 VDC off-state) |
| Communication | RS-485 (R4800 series) or 4–20 mA analog (R4900 series) |
| Housing Material | Stainless steel |
| Weight | 0.3 kg |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MET ONE 3400+ |
| Instrument Type | Optical Particle Counter |
| Flow Rates | 28.3 L/min, 50 L/min, 100 L/min |
| Standard Sizing Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm (model-dependent) |
| Laser Source | Long-life laser diode (MTBF ≥ 10 years) |
| Power | AC input 80–264 VAC |
| Dimensions | 26.7 × 26 × 21 cm (10.5" × 10.25" × 8.25") |
| Weight | 5.6 kg (no battery), 6.9 kg (with 2 cells) |
| Enclosure | 316 stainless steel |
| Operating Environment | 0–40°C, 10–90% RH (non-condensing) |
| Compliance | FDA 21 CFR Part 11 ready, ISO 21501-4, ISO 14644-1, EU GMP Annex 1 compatible |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MET ONE 6000 |
| Instrument Type | Optical Airborne Particle Counter |
| Particle Size Channels | Standard 2-channel (0.3 µm & 0.5 µm), optional 4-channel configuration |
| Light Source | Long-life laser diode |
| Dimensions | 17.15 × 11.43 × 31.75 cm (W × L × H) |
| Weight | 0.68 kg |
| Housing Material | 304 stainless steel |
| Power Supply | 9–28 VDC |
| Max. Power Consumption | 3.3 W (serial/pulse), 4.3 W (Ethernet) |
| Operating Temperature | 10–32 °C |
| Operating Humidity | 5–95% RH, non-condensing |
| Storage Temperature | −40–70 °C |
| Storage Humidity | 5–98% RH, non-condensing |
| Flow Control | Precision orifice-based |
| Flow Rate Options | 0.1 CFM (2.83 L/min) or 1.0 CFM (28.3 L/min) |
| Counting Efficiency | ≥50% at 0.3 µm |
| Coincidence Loss | ≤5% at 2×10⁶ particles/ft³ (7.06×10⁷ particles/m³) for 6002/6003 variants |
| False Count Rate | ≤1 particle per 5 minutes |
| Communication Interfaces | Pulse output, 4–20 mA analog, RS-232, RS-485 (Modbus RTU or FXB), Ethernet TCP/IP |
| Diagnostic Indicators | Multi-color LED status indicator (normal operation, count alarm, sensor fault, flow fault, comms fault) |
| Optional Sensors | Integrated temperature and relative humidity (RH/T) probe |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Imported |
| Model | MET ONE HHPC 2+ |
| Instrument Category | Optical Particle Counter |
| Particle Size Range | 0.5–5.0 µm |
| Channels | 2 |
| Flow Rate | 2.83 L/min |
| Counting Efficiency | 50% at 0.5 µm, 100% ≥0.75 µm (per ISO 21501-4) |
| Zero Count Level | ≤1 count / 5 min (per JIS B9921) |
| Maximum Concentration Limit | 4,000,000 particles/ft³ (10% coincidence loss, per ISO 21501-4) |
| Data Storage Capacity | 10,000 records |
| Display | 3.5″ color TFT, 320 × 240 pixels |
| Operating Temperature | 10–40 °C, ≤95% RH (non-condensing) |
| Battery Life | >10 h typical, ≥5.5 h continuous |
| Dimensions | 10.7″ × 3.9″ × 2.1″ |
| Weight | 1.5 lbs (0.68 kg) |
| Enclosure Material | Polycarbonate-ABS blend |
| Compliance | ISO 14644-1, ISO 21501-4, JIS B9921, FS 209E |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Multisizer 4e |
| Instrument Type | Electrical Sensing Zone (ESZ) Particle Analyzer |
| Measurement Principle | Coulter Principle (Electrical Sensing Zone) |
| Size Range | 0.4 µm – 1600 µm (diameter) |
| Volume Range | 0.033 fL – 2.145 × 10⁹ fL |
| Resolution | Up to 400 user-selectable channels |
| Compliance | ASTM D6913, ISO 13319, USP <788>, FDA 21 CFR Part 11, GLP/GMP-ready |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MET ONE 6000P |
| Instrument Type | Optical Airborne Particle Counter |
| Flow Rate Options | 0.1 cfm or 1.0 cfm |
| Sizing Thresholds | 0.3 µm and 0.5 µm |
| Channel Configurations | Standard 2-channel or optional 4-channel |
| Light Source | Long-life laser diode |
| Housing Material | Stainless steel |
| Dimensions | 17.15 × 11.43 × 31.75 cm (W × D × H) |
| Weight | 4.62 kg (10.2 lb) |
| Power Supply | 24 VDC ±10% or 100–230 VAC, 50/60 Hz |
| Max. Power Consumption | 50 W (DC), 7.9 W (AC) |
| Operating Temperature | 10–32 °C |
| Operating Humidity | 5–95% RH, non-condensing |
| Storage Temperature | −40–70 °C |
| Storage Humidity | 5–98% RH, non-condensing |
| Counting Efficiency Loss | ≤5% at 2×10⁶ particles/ft³ (7.1×10⁷ particles/m³) and at 4×10⁵ particles/ft³ (1.4×10⁷ particles/m³) |
| False Count Rate | ≤1 particle per 5 minutes |
| Flow Control | Microprocessor-based with differential pressure sensor |
| Pump Type | Integrated vacuum pump |
| Compliance | ISO 21501-4:2018, ISO 14644-1:2015, FDA 21 CFR Part 11 (data integrity support), EU GMP Annex 1 (2022) alignment |
| Output Interfaces | 4–20 mA analog, Ethernet TCP/IP, Modbus RTU (RS-485), pulse output, optional wireless modules |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Imported |
| Model | MET ONE HHPC 6+ |
| Instrument Category | Optical Particle Counter |
| Particle Size Range | 0.3–10 µm (6 channels per ISO 14644-1 & ISO 21501) |
| Flow Rate | 2.83 L/min |
| Weight | 1.5 lbs (0.68 kg) |
| Display | 3.5" color LCD (320 × 240) |
| Data Storage | 10,000 records |
| Counting Efficiency | 50% at 0.3 µm |
| Zero Count Level | ≤1 count/5 min (JIS B9921) |
| Maximum Concentration Limit | 4,000,000 particles/ft³ with <10% coincidence loss (ISO 21501) |
| Operating Environment | 10–40 °C, ≤95% RH (non-condensing) |
| Battery Life | ≥10 h typical, ≥5.5 h minimum continuous |
| Charging Time | 3.5 h |
| Housing Material | Polycarbonate-ABS blend |
| Dimensions | 10.7" × 3.9" × 2.1" (272 × 99 × 53 mm) |
| Connectivity | USB 2.0, Ethernet (HTTP-based web interface), USB flash drive support |
| User Interface Languages | English, Japanese |
| Alarm Configuration | User-defined particle count thresholds |
| Security | Optional administrator password protection |
Show next