| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC-manufactured) |
| Model | CytoFLEX o |
| Technology Platform | Nanoscale Flow Cytometry |
| Product Category | Flow Cytometer |
| Primary Use Case | Research |
| Lasers | 405 nm, 488 nm, 561 nm, 638 nm |
| Fluorescence Detection Channels | 6 |
| Coefficient of Variation (rCV) | <10% |
| Fluorescence Sensitivity (8-peak calibration beads) | V447: 8 peaks |
| 8531 | 8 peaks |
| Y595 | 8 peaks |
| R670 | 6 peaks |
| R710 | 5 peaks |
| R792 | 4 peaks |
| Sample Acquisition Rate | 16,000 events/sec |
| Automated Sample Loading | Yes |
| Sample Flow Rate | 6 µL/min |
| Compensation Method | Automatic |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | CytoFLEX LX |
| Technology Pathway | Analytical Flow Cytometry |
| Product Type | Flow Cytometry Analyzer |
| Primary Use Case | Research |
| Lasers | All channels support A (Area), H (Height), fixed W (Width), Time parameter, and absolute event count |
| Detection Channels | Full-channel rCV < 3% |
| Flow Rate | 10–240 µL/min |
| Fluorescence Sensitivity | ≤30,000 events per second (EPS) at 15-parameter acquisition |
| Cell Analysis Throughput | FITC < 30 MESF |
| Automated Sample Loading System | Yes |
| Acquisition Speed | Up to 30,000 events/second |
| Compensation Method | Fully automated, real-time digital compensation |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Navios EX |
| Technology Platform | Spectral Flow Cytometry |
| Instrument Type | Clinical-Grade Flow Cytometer |
| Laser Configuration | Up to 3 Lasers |
| Detection Channels | 12 |
| Forward Scatter (FSC) Collection Modes | Wide (1–18°), Narrow (1–8°), Wide Enhanced (optimized for submicron particles) |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CytoFLEX mosaic |
| Technology Pathway | Analytical Flow Cytometry |
| Product Type | Spectral Flow Cytometer |
| Application Domain | Research |
| Lasers | 4–6 |
| Detection Channels | 63–88 |
| Optical Resolution | 80 nm |
| Fluorescence Sensitivity | FITC < 30 MESF, PE < 10 MESF |
| Acquisition Rate | 30,000 events/sec |
| Automated Sample Loading | Yes |
| Sample Flow Rate | 10–240 µL/min |
| Compensation Method | Real-time Automatic Compensation & On-the-fly Spectral Unmixing |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Imported Instrument |
| Model | OPTIMA AUC |
| Detection Range | 5 µg/mL – 150 mg/mL |
| Sample Volume | 380 µL |
| Analysis Duration | Hours (typically 2–8 h per run) |
| Temperature Control Range | 0–40 °C |
| Detection Modes | UV-Vis Absorbance (190–800 nm) and Interference Optics |
| Simultaneous Wavelengths | Up to 20 |
| Maximum Rotor Capacity | 8 cells (An-50 Ti rotor) |
| Throughput | Up to 7 samples per run (standard configuration), up to 21 sample conditions via sequential or multi-temperature protocols |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Vi-CELL MetaFLEX |
| Pricing | Available Upon Request |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Navios |
| Product Category | Flow Cytometry Analyzer |
| Intended Use | Clinical Diagnostics |
| Lasers | 405 nm (violet), 488 nm (blue), 638 nm (red) |
| Detection Channels | Up to 10-color capability |
| Fluorescence Sensitivity | <112 MESF (FITC), <78 MESF (PE), <15 MESF (PC5) |
| Forward & Side Scatter Detection | Photodiode-based FSC/SSC |
| Fluorescence Detection | Photomultiplier Tube (PMT)-based |
| Optical System | Solid-state diode lasers with integrated flow cell |
| Flow Cell Dimensions | 150 µm × 460 µm rectangular quartz cuvette |
| Temperature Control | Integrated thermal regulation for optical path stability |
| Data Processing | Real-time digital signal processing |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Regulatory Certification | China NMPA Import Registration No. 20172401770 |
| Compliance | Designed for CLIA- and CAP-aligned clinical laboratories |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | BioLector XT |
| Vessel Dimensions | 95 × 514 × 541 mm |
| Aeration System | Innovative Gassing Lid with Precise Gas Mixing |
| pH Control Range | ~4.0–6.0 or ~5.0–7.5 (calibration-dependent) |
| Dissolved Oxygen (DO) Control Range | 0–100% air saturation (via O₂/N₂/CO₂ blending) |
| Temperature Control Range | −8 °C to +50 °C |
| Working Volume per Well | 800–2400 µL |
| Plate Format | ANSI/SLAS-compliant 48-well microtiter plate (MTP) |
| Sensor Technology | Non-invasive optical measurement (scattered light, fluorescence, absorbance, pH & DO via immobilized optodes) |
| Optional Modules | Microfluidic Feeding Module, Humidification Unit, Multi-gas Blending Controller |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Vi-CELL BLU |
| Assay Time | Fast Mode 80 s/sample, Standard Mode 110 s/sample |
| Cell Concentration Range | 2 × 10⁴ to 1.5 × 10⁷ cells/mL |
| Sample Volume | Fast Mode 170 µL, Standard Mode 200 µL |
| Throughput | 96 samples per run |
| Detectable Cell Size | 2–60 µm |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Biomek Echo |
| Pricing | Available Upon Request |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CytoFLEX S Series |
| Technology Pathway | Analytical Flow Cytometry |
| Product Type | Flow Cytometry Analyzer |
| Primary Use Case | Research |
| Laser Configuration | Up to four spatially separated lasers (375 nm, 405 nm, 488 nm, 561 nm) |
| Fluorescence Detection Channels | Up to 13 parameters with full-channel rCV < 3% |
| Optical Resolution | Side Scatter (488 nm) < 300 nm, Violet Side Scatter (405 nm) < 80 nm (vs. polystyrene beads) |
| Sample Flow Rate | 10–240 µL/min (user-selectable in 10/30/60 µL/min presets or fully adjustable) |
| Fluorescence Sensitivity | ≤30 MESF (FITC), ≤10 MESF (PE) at 15-parameter configuration |
| Event Acquisition Rate | Up to 30,000 events/sec (continuous, software-adjustable) |
| Automated Sample Loading | Integrated plate-based autosampler optional |
| Compensation Method | Real-time automatic compensation with saved compensation matrices |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | CytoFLEX Flow Cytometer |
| Technical Approach | Analytical Flow Cytometry |
| Product Type | Flow Cytometry Analyzer |
| Application | Research Use Only (RUO) |
| Laser Configuration | Up to 3 Lasers (405 nm, 488 nm, 638 nm) |
| Detection Channels | 13–15 parameters (configurable) |
| Optical Resolution | Full-channel rCV < 3% |
| Sample Flow Rate | Fixed at 10, 30, or 60 µL/min |
| user-definable range | 10–240 µL/min |
| Fluorescence Sensitivity | FITC < 30 MESF |
| Event Acquisition Rate | 30,000 events/sec |
| Automated Sample Loading | Yes |
| Compensation | Fully automated digital compensation |
| Voltage Adjustment | Not required (fixed-optics architecture) |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic IVD Instrument |
| Model | DxFLEX |
| Product Category | Clinical Flow Cytometry System |
| Application Domain | In Vitro Diagnostic (IVD) Laboratories |
| Laser Configuration | 3 Lasers / 13 Fluorescence Parameters |
| Fluorescence Sensitivity | ≤30,000 Equivalent Stained Particles (ESPs) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Sorting Flow Cytometer |
| Application Domain | Research |
| Laser Configuration | Up to 4 Lasers (405 nm, 488 nm, 561 nm, 638 nm) |
| Fluorescence Detection Channels | 15 Total (Configurable BPF Filters) |
| Optical Precision | rCV < 3% across all channels |
| Side Scatter Resolution | < 300 nm (488 nm excitation), < 200 nm (405 nm excitation) |
| Sample Flow Rate | 10–100 µL/min |
| FITC Sensitivity (488 nm) | < 30 MESF |
| Cell Acquisition Rate | 40,000 events/sec |
| Sorting Throughput | 30,000 cells/sec |
| Nozzle Diameter | 100 µm |
| Droplet Frequency | 35 kHz |
| Sorting Logic | Quadruple-Stream Sorting with Mixed-Mode and Discard-Capture Capability |
| Compensation | Fully Automated Real-Time Compensation |
| Sample Loading | Integrated Auto-Sampler (40,000 events/sec loading speed) |
| Voltage Adjustment Required | No |
| Biosafety Options | Optional Aerosol Containment Cabinet or Standalone Aerosol Exhaust System |
| Software Platform | CytExpert for CytoFLEX SRT (FDA 21 CFR Part 11–Ready Audit Trail, GLP/GMP-Compliant Data Integrity Features) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Kaluza |
| Product Type | Flow Cytometry Data Analysis Software |
| Intended Use | Research-Grade Flow Cytometry Data Processing |
| Minimum Display Resolution | 1440×900 |
| File Format Support | FCS 2.0/3.0/3.1, LMD |
| Operating System | Windows 7 (64-bit) and later |