Empowering Scientific Discovery

Beijing Aozuo Ecological Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAZ (Beijing Aozuo)
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeBenchtop
IntegrationFully Integrated System
Laser SourceNd:YAG, 200 mJ @ 1064 nm (266 nm optional)
Repetition Rate20 Hz
Pulse Width<6 ns
Spot Size20–200 µm (motorized adjustment)
Spectral Range190–1040 nm
DetectorBack-illuminated CCD with auto-height alignment
Safety ClassI (interlocked laser enclosure)
SoftwareElementLIBS & NIST spectral libraries, PLS/PCA modeling, mapping, autofocus, dual-lens control (wide-field + magnified), gas flow regulation, soil/plant calibration databases
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerodyne
OriginUSA
ModelAerodyne N2O
Instrument TypeStable Gas Isotope Ratio Mass Spectrometer (IRMS) Equivalent
Detection PrincipleTunable Infrared Laser Direct Absorption Spectroscopy (TILDAS)
Measurement TargetsN₂O, δ¹⁵Nα (¹⁵N¹⁴N¹⁶O), δ¹⁵Nβ (¹⁴N¹⁵N¹⁶O), δ¹⁸O (N₂O)
Detection Limit<1 ppt (v/v) for N₂O
Temporal Resolution1–10 Hz (configurable)
Path Length Options76 m or 400 m multipass cell
Precision (100 s)δ¹⁵Nα ≤ 0.08‰, δ¹⁵Nβ ≤ 0.5‰, δ¹⁸O ≤ 0.5‰
Operating Temperature Range10–35 °C (ambient)
with thermostatic enclosure−20 to +40 °C
Temperature Stability±0.1 °C at setpoint (typically 30 °C)
Power Requirement500 W, 120/240 VAC, 50/60 Hz (pump excluded)
Dimensions (76 m)650 × 430 × 270 mm (W×D×H)
Weight35 kg
Dimensions (400 m)560 × 770 × 640 mm
Weight75 kg
Sampling Flow Rate0–20 slpm
Data InterfacesRS-232, USB, Ethernet
Time SynchronizationGPS-enabled NTP server support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerodyne
OriginUSA
Instrument TypeStable Isotope Ratio Mass Spectrometry (IRMS)-Grade Laser Absorption Spectrometer
Measurement PrincipleTunable Infrared Laser Direct Absorption Spectroscopy (TILDAS) with Astigmatic Multipass Cell
Detection LimitsSub-ppt for N₂O, CH₄
δ¹³C-CO₂ precision0.02‰ (120 s)
δ¹⁸O-CO₂ precision0.03‰ (120 s)
Sampling Frequency1–10 Hz configurable
Certified ComplianceASTM D6348, ISO 13877 (adapted), GLP/GMP-ready data audit trail per FDA 21 CFR Part 11
SoftwareTDLWINTEL v5.2 with HITRAN spectral replay, zero-spectrum background subtraction, real-time laser frequency stabilization, and passive cavity drift correction