BrandAZ (Beijing Aozuo)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelAZ-iChamber
Height Options0.5 / 0.8 / 2.0 m
Footprint Options0.08 / 0.3 / 1.0 m²
ConfigurableTransparent or Opaque
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAZ (Beijing AoZuo)
OriginBeijing, China
Manufacturer TypeManufacturer
Regional CategoryDomestic (China)
ModelENVIdata-Redox
Output Range (pH electrode)−175 to +175 mV (corresponding to pH 4–10, pH 7 = 0 mV)
Electrode Diameter (pH)6 mm
Electrode Length (pH)80 mm
Protective Sleeve Diameter20 mm
Protective Sleeve Max Length1 m
Cable Length2 m (customizable)
Reference ElectrodeAg/AgCl with 3 M KCl electrolyte, ceramic junction, PVC body
Field Reference Electrode DimensionsØ12 mm × 110 mm
Salt BridgeØ25 mm × 400 mm
Lab Reference Electrode DimensionsØ6 mm × 80 mm
Salt BridgeØ12 mm × 120 mm
Redox Electrode TipPt wire, Ø1 mm × 5 mm
Redox Electrode BodyCarbon fiber tube, Ø6 mm
Redox Reference ElectrodeØ12 mm × 120 mm
Redox Control Module Range±1250 mV
Resolution0.1 mV
Accuracy±3 mV
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAZ (Beijing Aozuo)
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelENVIdata-SFL
Instrument TypeSoil Moisture / Matric Potential Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAZ (Beijing Aozuo)
OriginGermany
ManufacturerYes
Country of OriginImported
ModelAZ-S0210
Instrument TypeContaminant Transport Analyzer
Key ParametersIn-situ multi-depth soil water content, matric potential, temperature, and pore-water solute extraction (NO₂⁻, NO₃⁻+NO₂⁻, PO₄³⁻, SiO₄⁴⁻, NH₄⁺, Ca²⁺, Cl⁻, Fe²⁺/³⁺, total P, total N, SO₄²⁻, alkalinity, hardness, Cr(VI), CN⁻, N₂H₄, volatile phenols)
Sampling FrequencyConfigurable from 1 s to 24 h per sensor channel
Sensor Depth ResolutionField-scale intact monoliths (1 m Ø × 2 m depth) with sensors at 30, 60, 120, 180 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAZ (Beijing Aozuo Ecological Instruments Co., Ltd.)
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelAZG-300
PriceUpon Request
Measurement PrincipleNDIR for CO₂
CO₂ Range0–2000 ppm (optional: 0–5000 / 0–10,000 / 0–80,000 ppm)
CH₄ Range0–100 ppm (optional: 0–100% vol)
CO₂ Resolution0.01 ppm
CH₄ Resolution0.1 ppm
Accuracy≤ ±1% F.S.
Gas Flow Control0.1–1 L/min
Warm-up Time20 min
Response Time (T₉₀)2 s
Output InterfaceRS232
DisplayColor TFT touchscreen
Operating Temp.0–45 °C
Operating Humidity1–98% RH (non-condensing)
Power SupplyAC 85–265 V, 40 W
Dimensions (Analyzer)57 × 41 × 22 cm
iChamber OptionsØ0.35 m × 0.5 m (0.08 m²), Ø0.62 m × 0.8 m (0.3 m²), Ø1.2 m × 1.5 m (1.0 m²)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAZ (Beijing)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelSmartSoil
Instrument TypeMulti-Parameter Field Soil Warming and Monitoring System
Heating Area7 m²
Supply Voltage380 V AC
Total Heating Power5 kW per Heating Zone
Adjustable Warming Range+0.1 °C to +5.0 °C above ambient
Temperature Uniformity ControlAchieved via in-soil distributed heating elements
Monitoring Points10 embedded PT100 sensors within warming zone
Auxiliary ConfigurationOptional vertical column integration for concurrent soil moisture and temperature regulation
Perimeter Maintenance Zone1 m width × 2 m depth annular trench surrounding active area
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandAZ (Beijing AoZuo Ecological Instruments Co., Ltd.)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelSoilScope
Instrument TypeMulti-Functional Soil Hydrological Monitoring Lysimeter
ComplianceDesigned for ISO 27025-aligned environmental monitoring labs, supports GLP/GMP data integrity requirements via EcoScope software audit trail]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAZ (Beijing Aozuo)
OriginBeijing, China
ManufacturerAZ Instrument Co., Ltd.
ModelAZ-SF-1
Instrument TypeMultiparameter Open-Channel Flow Monitoring System
Ultrasonic Water Level Sensor Range0–400 mm
Resolution0.1 mm
Accuracy±1% FS
Temperature CompensationBuilt-in
Weir Dimensions1000 mm (L) × 600 mm (W) × 400 mm (H), 304 Stainless Steel
Data Logger6 single-ended / 4 differential analog inputs, 8 pulse channels, SDI-12, RS232, USB, Ethernet
sampling interval10 ms to 24 h
operating temperature−45 °C to +70 °C
Rain GaugeResolution 0.2 mm, accuracy ±1.0%, orifice diameter 154 mm
Power Supply10–30 VDC, solar-battery hybrid compatible
CommunicationGPRS, USB, RS232, Ethernet
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAZ (Beijing AoZuo Ecological Instruments Co., Ltd.)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelLP-100
Measurement MethodControlled-airflow particle resuspension coupled with real-time optical particle detection
Measured ParametersTSP, PM₁₀, PM₂.₅, PM₁.₀ dust retention per unit leaf area
Measurement Range0–60 mg/m³ (indicator range), 0–6 mg/m³ (quantitative accuracy range)
Measurement Interval1 s – 4 h
Sampling Flow Rate600 cm³/min
LOD0.01 µg/m³
Flow Stability±0.1% over 5-min measurement cycle
Particle Size Detection Range0.5–20 µm (aerodynamic diameter)
Wind Speed Range (integrated sensor)0–60 m/s, resolution 0.1 m/s, accuracy ±3%
Temperature Range−40 to +55 °C, resolution 0.1 °C, accuracy ±0.2 °C
Relative Humidity Range1–100%, resolution 0.1%, accuracy ±3–5%
Rainfall Rate Range0–4 mm/min, resolution 0.1 mm, accuracy ±4%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAZ (Beijing Aozuo)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModeliChamber-G
PricingUpon Request
Data Logger CPU32-bit FPU processor, 180 MHz
Sensor Channels40 SDI-12 ports (expandable)
Memory512 MB
Display2.54" OLED
ConnectivityIntegrated 4G module with embedded IoT SIM card
CH₄ Range0–100 ppm, Accuracy ≤10 ppb
N₂O Range0–100 ppm, Accuracy ≤10 ppb
CO₂ Range0–10,000 ppm, Accuracy ≤0.15 ppm
NO Range0–100 ppm, Accuracy ≤10 ppb
H₂O Range0–5% v/v, Accuracy ≤1 ppm
Soil Gas Probe Pore Size0.1 µm
Gas Exchange Surface Area110 cm²
Cavity Volume20 mL
Probe Diameter12 mm
Probe Length Options150 mm or 300 mm
Tubing LengthStandard 3 m (extendable to 5 m)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAZ (Beijing Aozuo Ecological Instruments Co., Ltd.)
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Regional ClassificationDomestic (China)
ModelSeedScope
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerodyne
OriginUSA
ModelAerodyne TILDAS Series (Configurable Dual-Laser Platform)
PrincipleMid-Infrared Tunable Diode Laser Direct Absorption Spectroscopy (TILDAS)
TypeContinuous Online Analyzer
Response Time≤1 s (10 Hz measurement capability)
Detection LimitsSub-ppt (1σ, 1 s) for CO, CO₂, CH₄, C₂H₄, HCHO, CHOOH, COS, SO₂, NO, N₂O, NO₂, NH₃, HONO, HNO₃, HOD, ¹³C-CO₂, ¹⁸O-CO₂, ¹⁷O-CO₂, ¹⁵N¹⁴N¹⁶O (δ¹⁵Nα), ¹⁴N¹⁵N¹⁶O (δ¹⁵Nβ)
Optical Path Length76 m or 210 m (Astigmatic Multipass Cell)
Multi-Platform DeploymentFixed-site, eddy covariance towers, automated soil flux chambers, mobile platforms (vehicle, aircraft, marine vessel)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerodyne
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelCAPS PMex
Instrument PrincipleCavity Attenuated Phase Shift Spectroscopy (CAPS)
Product TypeOnline Continuous Monitor
Response Time<2 s
RepeatabilityCO, CO₂, CH₄, C₂H₄, HCHO, CHOOH, COS, SO₂, NO, N₂O, NO₂, NH₃, HONO, HNO₃, ¹³C-CO₂, ¹⁸O-CO₂, ¹⁷O-CO₂, HOD, ¹⁵N¹⁴N¹⁶O (δ¹⁵Nα), ¹⁴N¹⁵N¹⁶O (δ¹⁵Nβ)
Wavelength Options405 nm, 450 nm, 525 nm, 630 nm, 660 nm, 780 nm (up to 4 simultaneously selectable)
Linear Range0–4000 Mm⁻¹
Sensitivity2.5 Mm⁻¹ (1 s), 0.25 Mm⁻¹ (60 s)
Sample Flow Rate0.85 L/min per cavity
Operating PressureAmbient
Materials in Contact with SampleConductive polyurethane, stainless steel, conductive silicone, aluminum
Data OutputRS-232, USB, Ethernet
Onboard Storage5 years of data
Dimensions61 cm × 43 cm × 31 cm
Weight15 kg
Power<100 W, 100–250 VAC (50–60 Hz)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADC Bio
OriginUnited Kingdom
ModelACE
Instrument TypeMulti-parameter Soil Respiration Analyzer
CO₂ Measurement Range0–896 ppm
Resolution1 ppm
Accuracy±1% of reading
IRGA Drift≤0.6% per 24 h
PAR Sensor0–3000 µmol m⁻² s⁻¹ (Silicon Photodiode)
Soil Temperature Range−20 to +50 °C
Soil Moisture (SM300)0–100 vol%, ±3% (soil-calibrated)
Soil Moisture (Theta Probe)0–1.0 m³·m⁻³, ±1% (factory-calibrated)
Flow Control200–5000 mL/min (±3% accuracy)
Chamber VolumesClosed-mode 2.6 L, Open-mode 1.0 L
Chamber Diameter23 cm
Power Supply12 V DC, 40 Ah battery (28 days continuous operation)
Data Storage1 GB CompactFlash card (up to 4 million records)
CommunicationRS-232 (up to 19200 baud), rugged 3-pin waterproof connector
Display240 × 64 pixel LCD
Dimensions (H×W×D)82 × 33 × 13 cm
Weight7.0 kg
Network CapacityUp to 30 units within 200 m radius
Operating ModesClosed-chamber and open-path configurable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerodyne
ModelCPEC-AZ
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
PriceUSD 1,400 (approx. ¥10,000)
Measurement Frequency10 Hz (configurable 1–10 Hz)
Detection LimitSub-ppt Level
Temperature-Controlled Enclosure±0.07 °C stability, operating range −20 to +40 °C
Sample Flow Rate0.5–20 SLPM
Data InterfacesRS-232, USB, Ethernet
System Weight35 kg (core unit) / 75 kg (full configured system)
Power Requirement250 W, 120/240 V AC, 50/60 Hz
TILDAS Analyzer Gas PerformanceN₂O (1-s precision: 0.03 ppb), CH₄ (0.25 ppb), CO₂ (100 ppb), NH₃ (40 ppt), H₂O (10 ppm), COS (0.005 ppb), NO (0.15 ppb), NO₂ (0.03 ppb), HONO (0.21 ppb)
dynamic range0–10,000 ppb (N₂O, CH₄, NH₃, COS, NO, NO₂, HONO), 0–5,000 ppm (CO₂, H₂O, O₃, CO)
iChamber SpecificationsFootprint options: 1.0 m² × 1.5 m height, 0.3 m² × 0.8 m, or 0.08 m² × 0.5 m
sealing integrity<2 kPa pressure loss over 60 s under −5 kPa differential
wind resistanceup to Beaufort Scale 12
operational temperature−20 to +55 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerodyne
OriginUSA
ModelAerodyne CO2
Detection PrincipleTunable Infrared Laser Direct Absorption Spectroscopy (TILDAS)
ConfigurationOnline, Benchtop
Response Time<1 s
Measured Isotopologues¹³C¹⁶O₂, ¹²C¹⁶O¹⁸O, ¹²C¹⁷O¹⁶O, ¹²C¹⁶O²H, HOD, ¹⁵N¹⁴N¹⁶O (δ¹⁵Nα), ¹⁴N¹⁵N¹⁶O (δ¹⁵Nβ), COS, SO₂, NO, N₂O, NO₂, NH₃, HONO, HNO₃, CH₄, C₂H₄, HCHO, CHOOH, CO
Precision (Δ₆₃₈)0.01‰ (SE, 16 min, ≤1.6 mg calcite)
Path Length400 m (astigmatic multipass cell)
Power Consumption250–500 W (120/240 V, 50/60 Hz, without pump)
Dimensions560 × 770 × 640 mm (W × D × H)
Weight75 kg
Data InterfacesRS-232, USB, Ethernet
Operating Environment10–35 °C, 0–20 slpm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerodyne
OriginUSA
ModelCAPS PMssa
PrincipleCavity Attenuated Phase Shift (CAPS) Spectroscopy
Form FactorContinuous Online Monitor
Response Time1 s
Sensitivity3.0 Mm⁻¹ (1 s), 0.5 Mm⁻¹ (60 s)
SSA Uncertainty±0.03 (30 s integration)
Wavelength Options405 nm, 450 nm, 525 nm, 630 nm, 660 nm, 780 nm
Sample Flow Rate0.85 L/min
Operating PressureAmbient
Housing Dimensions61 cm × 43 cm × 23 cm
Weight16 kg
Power200–250 V AC, 50–60 Hz, 50–100 W
Data InterfacesRS-232, USB, Ethernet
Onboard Storage≥5 years of high-resolution time-series data
Wetted MaterialsConductive polyurethane, stainless steel, conductive silicone, aluminum
DisplayIntegrated real-time LCD interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerodyne
OriginUSA
ModelAerodyne TILDAS-CNW
Detection PrincipleTunable Infrared Laser Direct Absorption Spectroscopy (TILDAS)
ConfigurationOnline Continuous Analyzer
Response Time<1 s (up to 10 Hz measurement frequency)
RepeatabilityCH₄, δ¹³C(CH₄), N₂O, δ¹⁵N¹⁴N¹⁶O, δ¹⁴N¹⁵N¹⁶O, δ¹⁸O(N₂O), CO₂, δ¹³C(CO₂), δ¹⁸O(CO₂), H₂O, δ¹⁸O(H₂O), δHDO
Measurement RangeCH₄: 2–20 ppm
N₂O0.3–100 ppm
CO₂300–1000 ppm or 0.1–0.3 µmol/mol
H₂O0–4%
Precision (1 s / 100 s)CH₄: 0.2 / 0.05 ppb
δ¹³C(CH₄)1.0 / 0.2 ‰
N₂O0.03 / 0.01 ppb
δ¹⁴N¹⁵N¹⁶O6.0 / 1.5 ‰
δ¹⁵N¹⁴N¹⁶O9.0 / 2.3 ‰
δ¹⁸O(N₂O)12.0 / 3.0 ‰
CO₂0.1 / 0.03 ppm
δ¹³C(CO₂)0.1 / 0.03 ‰
δ¹⁸O(CO₂)0.1 / 0.03 ‰
H₂O10 / 5 ppm
δ¹⁸O(H₂O)0.1 / 0.03 ‰
δHDO0.3 / 0.1 ‰
Operating Temperature10–35 °C
Humidity Range5–95 % RH (non-condensing)
Sampling Flow Rate0–20 SLPM
Data InterfacesRS232, USB, Ethernet
Dimensions530 × 660 × 710 mm (W×D×H)
Weight72 kg
Power500 W, 120/240 VAC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerodyne
OriginUSA
ModelSIX
Detection PrincipleTunable Infrared Laser Direct Absorption Spectroscopy (TILDAS)
ConfigurationOnline, Real-Time
Response Time<1 s (10 Hz data acquisition)
Measurement SpeciesNH₃, O₃, CO₂, CH₄, N₂O, H₂O
Isotopic Capability¹³C-CO₂, ¹⁸O-CO₂, ¹⁷O-CO₂, HOD, ¹⁵N¹⁴N¹⁶O (δ¹⁵Nα), ¹⁴N¹⁵N¹⁶O (δ¹⁵Nβ)
Path LengthUp to 210 m (Patented Astigmatic Multipass Cell)
Detection Limits (1σ)NH₃: 50 ppt (1 s), 15 ppt (100 s)
O₃400 ppt (1 s), 100 ppt (100 s)
CO₂0.25 ppm (1 s), 0.06 ppm (100 s)
N₂O80 ppt (1 s), 20 ppt (100 s)
CH₄400 ppt (1 s), 100 ppt (100 s)
H₂O10 ppm (1 s), 5 ppm (100 s)
Operating Temperature10–35 °C
Relative Humidity5–95 % RH
Sample Flow Rate0–20 slpm
Data InterfacesRS232, USB, Ethernet
Dimensions (W×D×H)560 × 770 × 640 mm
Weight75 kg
Power250–500 W, 120/240 VAC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerodyne
OriginUSA
ModelTILDAS-N2O
Detection PrincipleTunable Infrared Laser Direct Absorption Spectroscopy (TILDAS)
Measurement RangeSub-ppt to ppm N₂O
Precision≤30 ppt (1σ, 1 s integration)
Temporal ResolutionUp to 10 Hz
Optical Path Length76 m (multipass cell)
Wavelength RegionMid-IR (e.g., 2200 cm⁻¹ for N₂O/CO
Response Time (1/e)<0.1 s
Operating Temperature−20 to +50 °C
Sample Flow Rate0–20 slpm
Power Consumption250 W (excl. vacuum pump)
Dimensions440 mm × 660 mm × 267 mm (6U rack-mountable)
Weight35 kg (main unit) + 15 kg (TE cooler)
Data InterfacesRS-232, USB, Ethernet
SoftwareTDLWintel v5.x (real-time control, automated valve sequencing, background subtraction, GLP-compliant audit trail)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAERODYNE
OriginBeijing, China
ModelEcoCosm
Instrument TypeOnline Fixed-Station System
Measurement RangeO₃: 0–200 nmol·mol⁻¹ (ppb)
CO₂0–1000 ppm
Co-measured GasesCO, CH₄, N₂O, NO, NO₂
OTC CapacityUp to 15 Open-Top Chambers (OTCs)
Control Resolution< ±2 nmol·mol⁻¹ O₃
Sampling IntervalConfigurable (default 10 min)
Imaging Frequency1 image per OTC per hour
ComplianceDesigned for GLP-aligned environmental exposure studies
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerodyne
OriginUSA
ModelTILDAS-CO2/CH4/N2O
Detection PrincipleTunable Infrared Laser Direct Absorption Spectroscopy (TILDAS)
ConfigurationOnline, Closed-Path
Response Time≤1 s (selectable 1–10 Hz)
Precision (1 s)CO₂: 100 ppb, CH₄: 0.1 ppb, N₂O: 0.03 ppb, H₂O: 10 ppm, δ¹³C-CO₂: 0.1‰, δ¹⁸O-CO₂: 0.03‰
Measurement RangeCO₂: 0–5000 ppm, CH₄/N₂O: 0–10 000 ppb, H₂O: 0–5000 ppm, δ¹³C/δ¹⁸O: ±0.5‰
Effective Optical Path Length210 m (Astigmatic Multipass Cell)
Detection LimitSub-ppt for key trace gases
ComplianceDesigned for GLP/GMP-aligned operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerodyne
OriginUSA
Manufacturer TypeAuthorized Distributor
Product TypeOnline Analytical System
Measurement PrincipleTunable Infrared Laser Direct Absorption Spectroscopy (TILDAS)
Response Time1 s (10 Hz acquisition rate)
Repeatability±0.2‰ for δ¹³C(CH₄), ±1.5‰ for δ¹⁴N¹⁵N¹⁶O, ±0.03 ppb for N₂O (100 s avg), ±0.05 ppb for CH₄ (100 s avg), ±0.03 ppm for CO₂ (100 s avg), ±0.03‰ for δ¹⁸O(CO₂), ±0.03‰ for δ¹⁸O(H₂O), ±0.1‰ for δHDO (100 s avg)
Measured Species & IsotopologuesCH₄, δ¹³C(CH₄), N₂O, δ¹⁵N¹⁴N¹⁶O, δ¹⁴N¹⁵N¹⁶O, δ¹⁴N¹⁴N¹⁸O, CO₂, δ¹³C(CO₂), δ¹⁸O(CO₂), H₂O, δ¹⁸O(H₂O), δHDO