- All
- Favorite
- Popular
- Most rated
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | vAPCI |
| Instrument Type | Ion Source |
| Application Specificity | Dedicated Gas-Phase Interface |
| Analyte Polarity Range | Non-polar to Moderately Polar Compounds |
| Sensitivity | Compatible with Advion expression CMS Mass Spectrometer |
| Resolution | Defined by Coupled Mass Analyzer (e.g., Quadrupole) |
| Accurate Mass Capability | ±0.1 Da (when calibrated and operated under optimized conditions) |
| Operating Pressure | Ambient Atmospheric Pressure (~760 Torr) |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash 5.250 |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.1–250 mL/min |
| Maximum Operating Pressure | 250 bar |
| UV-Vis Wavelength Range | 200–800 nm |
| Application Level | Laboratory-Scale to Pilot-Scale Purification |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash XS 520plus |
| Application Level | Laboratory Grade |
| Instrument Type | Medium- to Low-Pressure Preparative LC |
| Flow Rate Range | 0.1–300 mL/min |
| Maximum Operating Pressure | 20 bar |
| Column ID Compatibility | Up to 80 mm |
| Typical Prep Scale | 4–800 g |
| Detector Options | UV/Vis, iELSD, Mass Spectrometry (MS) Interface Capable |
| Software Platform | InterSoft X |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | iASAP Inert Gas Atmospheric Pressure Solid Analysis Probe |
| Instrument Type | APCI Ion Source |
| Application Scope | General-Purpose |
| Mass Range | 10–2000 m/z |
| Sensitivity | S/N ≥ 100:1 (1 pg reserpine) |
| Resolution | 0.5–0.85 m/z (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Compliance | Compatible with Advion expression® CMS and compact CMS platforms |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash 5.015-XL |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | Medium-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0–825 mL/min |
| Maximum Operating Pressure | 15 bar |
| UV Detection Wavelength Range | 200–800 nm |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | Plate Express TLC |
| Operation Mode | Automated |
| Desolvation | Nitrogen Purge |
| Sample Platform | Adjustable for Standard TLC Plates (e.g., 20 × 20 cm, 10 × 20 cm, 5 × 10 cm) |
| Compatibility | Designed for Integration with Expression® CMS Compact Mass Spectrometer |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash 5.050 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0–250 mL/min |
| Maximum Operating Pressure | 50 bar |
| UV Detection Wavelength Range | 200–800 nm |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Instrument Type | Single Quadrupole |
| Mass Range | m/z 10–2000 |
| Sensitivity | 100:1 (S/N) |
| Resolution | 0.5–0.85 Da (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Ionization Sources | ESI, APCI, ASAP, OPSI, iASAP, vAPCI |
| Models | expression S (up to m/z 1200), expression L (up to m/z 2000) |
| Vacuum Recovery Time | <30 min after relocation |
| Compliance | Fully compatible with 21 CFR Part 11 via DataApex Clarity and DataExpress software |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | puriFlash® Active Splitter |
| Pricing | Available Upon Request |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | puriFlash 5.400 |
| Flow Rate Range | 0–125 mL/min |
| Maximum Pressure | 400 bar |
| Wavelength Range | 200–800 nm |
| Wavelength Reproducibility | ±0.5 nm |
| Detection Channels | Dual-wavelength (UV-Vis) with full-spectrum acquisition capability |
| Column ID Support | Up to 60 mm |
| Sample Capacity | 132-tube rack (18 × 150 mm), configurable for alternative formats |
| Touchscreen Interface | 15-inch HD capacitive touchscreen |
| Gradient Capability | Quaternary solvent delivery |
| Injection Modes | Liquid injection and dry-load (Load&Go) via 6-port + 10-port valve manifold |
| Flow Cell | 1.0 mm pathlength, 20 µL volume |
| Compliance | Designed for GLP-compliant workflow execution |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | puriFlash 5.020 |
| Application Level | Laboratory Grade |
| Instrument Type | Medium- to Low-Pressure Preparative LC |
| Flow Rate Range | 0–300 mL/min |
| Maximum Operating Pressure | 20 bar |
| UV Wavelength Range | 200–800 nm (with optional extended UV pack) |
| Data Acquisition Rate | 1 Hz (not amu — corrected per instrument context) |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | puriFlash 5.250P |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.1–125 mL/min |
| Maximum Operating Pressure | 250 bar |
| UV Wavelength Range | 200–800 nm |
| Detection Cell | 1.3 mm pathlength, 55 µL volume |
| Gradient Capability | Quaternary solvent delivery with automated degassing |
| Column Compatibility | Up to 60 mm internal diameter |
| Fraction Collection | 132-position rack (18 × 150 mm tubes, configurable) |
| Control Interface | 15″ HD capacitive touchscreen |
| Software Platform | InterSoft X Genius (KISS-compliant, drag-and-drop gradient editor, method automation, audit-trail-ready) |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash 535-XL |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0–400 mL/min |
| Maximum Operating Pressure | 35 bar |
| UV Detection Wavelength Range | 200–800 nm |
| Brand | Advion |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ICP-001/E01 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Mass Resolution (at 10% peak height, unit mass) | 0.9 amu |
| Detection Limits (ng·L⁻¹) | Be < 1 |
| Sensitivity (Mcps / mg·L⁻¹) | Li > 20 |
| Brand | Bohui |
|---|---|
| Origin | Beijing, China |
| Model | BH5100T |
| Analysis Method | Flame Atomic Absorption Spectrometry (FAAS) |
| Simultaneous Multi-Element Detection | Cu, Zn, Ca, Mg, Fe |
| Atomizer | Pre-mixed 100 mm single-slit titanium burner |
| Wavelength Range | 190–650 nm |
| Spectral Bandwidth | 0.15–2.0 nm |
| Absorbance Range | 0–2 Abs |
| Baseline Stability | ≤0.005 Abs (30 min, unignited) |
| Characteristic Concentrations (Cu/Zn/Ca/Mg/Fe) | ≤0.035 / ≤0.015 / ≤0.080 / ≤0.040 / ≤1.05 mg/L per 1% absorption |
| Precision | ≤1.0% RSD (Abs > 0.1) |
| Sample Volume | 20 µL (Enhanced) or 40 µL (Standard) whole blood |
| Power Supply | AC 220 ± 22 V, 50 ± 1 Hz, 300 VA |
| Dimensions | 720 × 520 × 275 mm |
| Operating Environment | 10–30 °C, RH ≤70%, no vibration/corrosive gases/EMI |
| Safety Compliance | Overpressure Category II, integrated acetylene flashback arrestor, pressure/flow dual monitoring, automatic gas cutoff on power loss or low air pressure |
| Software | Dedicated clinical data management system with GLP-compliant audit trail, automated calculation, storage, and report generation (graphical + tabular output) |
| Brand | Bohui Innovation |
|---|---|
| Origin | Beijing, China |
| Model | BH2200S |
| Analysis Method | Graphite Furnace Atomic Absorption Spectrometry (GFAAS) |
| Wavelength Range | 190–650 nm |
| Spectral Bandwidth | 0.10–2.0 nm |
| Absorbance Range | 0–2 Abs |
| Baseline Stability | ≤0.009 Abs/20 min (after 30-min warm-up) |
| Detection Sensitivity | Pb > 0.055 Abs, Cd > 0.025 Abs (≤50 µL injection) |
| Precision | ≤2.9% RSD (Abs > 0.1) |
| Background Correction Capacity | >30× at ~1.0 Abs |
| Signal Measurement | Dual-channel simultaneous detection |
| Power Supply | AC 220 V, 50 Hz |
| Operating Temperature | 10–30 °C |
| Atmospheric Pressure | 0.070–0.106 MPa |
| Dimensions (Main Unit) | 782 × 560 × 338 mm |
| Dimensions (Graphite Furnace Power Supply) | 335 × 470 × 265 mm |
| Brand | Bohui |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BH400 |
| Pricing | Available Upon Request |
| Detection Principle | Fluorescent Immunochromatography (Dual-Antibody Sandwich) |
| Assay Format | Multiplex Lateral Flow Immunoassay (LFIA) |
| Target Analytes | Rotavirus, Enteric Adenovirus, Norovirus, Astrovirus |
| Measurement Mode | Quantitative Fluorescence Intensity (Excitation/Emission Optimized for Europium Chelate or Similar Lanthanide Label) |
| Linear Range | 0–500 ng/mL (Fluorescein Reference Standard) |
| Background Noise | <50 fluorescence units (10 consecutive blank test strip readings, mean) |
| Accuracy | ±5% of labeled value (fluorescein calibrator) |
| Precision (CV) | ≤10% at 100 ng/mL |
| Stability | <5% signal drift within 20 min |
| Total Assay Time per Sample | <30 s (instrument readout only |
| full assay including sample application and migration | ≤60 min) |
| Power Supply | AC 220 V, 50 Hz |
| Operating Environment | Indoor use |
| Dimensions (W×D×H) | 400 × 436 × 200 mm |
| Brand | Bohui Innovation |
|---|---|
| Origin | Beijing, China |
| Model | BH2101S |
| Analytical Method | Tungsten-Boat Electrothermal Atomic Absorption Spectrometry (ETAAS) |
| Wavelength Range | 190–650 nm |
| Spectral Bandwidth | 1.0–2.0 nm |
| Absorbance Range | 0–2 Abs |
| Baseline Stability | ≤0.009 Abs/20 min (Pb & Cd, after 30-min preheating) |
| Sensitivity | Pb >0.055 Abs, Cd >0.025 Abs (≤50 µL sample) |
| Precision | ≤4.5% RSD (Abs >0.1) |
| Background Correction | Self-reversal (self-absorption) method |
| Measurement Mode | Dual-channel simultaneous detection (Pb & Cd) |
| Power Supply | AC 220 V, 50 Hz, 600 VA |
| Dimensions | 780 × 560 × 470 mm (L×W×H) |
| Weight | 45 kg |
| Operating Environment | 10–30 °C, 0.070–0.106 MPa, vibration-free, non-corrosive, low-EMI |
| Brand | Bohui Innovation |
|---|---|
| Origin | Beijing, China |
| Model | BH5500S |
| Analysis Method | Flame Atomic Absorption Spectrometry (FAAS) |
| Sample Types | Whole Blood, Serum, Breast Milk, Urine |
| Simultaneous Multi-Element Detection | Cu, Zn, Ca, Mg, Fe |
| Atomizer | Premixed 100 mm Single-Slit Titanium Burner |
| Wavelength Range | 190–650 nm |
| Spectral Bandwidth | 0.15–2.0 nm |
| Absorbance Range | 0–2 Abs |
| Baseline Stability | ≤0.005 Abs per 30 min (for Cu, Zn, Ca, Mg, Fe) |
| Precision | ≤1.0% RSD (Abs > 0.1) |
| Light Sources | Composite Hollow Cathode Lamps (Cu/Zn/Ca |
| Monochromator | Holographic Grating |
| Nebulizer | Optimized High-Efficiency Pneumatic Nebulizer |
| Nebulization Chamber | PTFE-lined with Tapered Geometry and Rear Drain Design |
| Burner Head | Pure Titanium |
| Safety Systems | Acetylene Anti-Flashback Valve, Pressure/Flow Dual Monitoring, Power-Fail Cut-off, Burner Explosion Protection |
| Power Supply | AC 220 ± 22 V, 50 ± 1 Hz, 300 VA |
| Dimensions | 782 × 560 × 338 mm |
| Operating Environment | 10–30 °C, RH ≤70%, Atmospheric Pressure 0.070–0.106 MPa, Vibration-Free & Corrosion-Free Ambient |
| Software | Integrated Clinical FAAS Data Acquisition & Reporting Suite with Audit Trail Capability |
| Brand | Bohui Innovation |
|---|---|
| Origin | Beijing, China |
| Model | BH5300S |
| Analysis Method | Flame Atomic Absorption Spectrometry (FAAS) |
| Sample Types | Whole Blood (40 µL) and Serum (300 µL) |
| Simultaneous Multi-Element Detection | Cu, Zn, Ca, Mg, Fe |
| Atomizer | Premixed 100 mm Single-Slit Titanium Burner |
| Absorbance Range | 0–2 Abs |
| Wavelength Range | 190–650 nm |
| Spectral Bandwidth | 0.15–2.0 nm |
| Light Sources | Composite Hollow Cathode Lamps (Cu/Zn/Ca |
| Baseline Stability | ≤0.005 Abs per 30 min |
| Characteristic Concentrations (Whole Blood) | Cu ≤0.035 mg/L/%, Zn ≤0.015 mg/L/%, Ca ≤0.080 mg/L/%, Mg ≤0.040 mg/L/%, Fe ≤1.05 mg/L/% |
| Characteristic Concentrations (Serum) | Cu ≤0.035 mg/L/%, Zn ≤0.020 mg/L/%, Ca ≤1.30 mg/L/%, Mg ≤0.20 mg/L/%, Fe ≤0.15 mg/L/% |
| Precision | ≤1.0% RSD (Abs > 0.1) |
| Safety Compliance | Overpressure Category II, Integrated Acetylene Anti-Flashback Valve, Air Pressure & Flow Monitoring, Power-Fail Flame Cutoff, Burner Explosion Protection |
| Power Supply | AC 220 ±22 V, 50 ±1 Hz, 300 VA |
| Dimensions | 782 × 560 × 338 mm |
| Operating Environment | 10–30 °C, RH ≤70%, Atmospheric Pressure 0.070–0.106 MPa, Vibration-Free, Corrosion- and EMI-Free |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash® Active Splitter |
| Flow Path Architecture | Active Valve-Based Splitting |
| Split Ratio Control | Software-Defined Switching Frequency |
| Pressure Management | Zero Backpressure Generation |
| Compatibility | Interchim puriFlash® Systems & All Interchim HPLC/UHPLC Columns |
| Detection Integration | Simultaneous UV + MS Trigger Logic |
| Software Control | Intersoft® X Platform (FDA 21 CFR Part 11 Compliant Audit Trail Optional) |
| Brand | Bohui Innovation |
|---|---|
| Origin | Beijing, China |
| Model | BH2100T |
| Absorbance Range | 0–2 Abs |
| Wavelength Range | 190–650 nm |
| Baseline Stability | ≤0.009 A (after 30-min preheat, 20-min measurement) |
| Sensitivity (Pb) | ≥0.055 Abs at ≤50 µL |
| Sensitivity (Cd) | ≥0.025 Abs at ≤50 µL |
| Precision (Pb/Cd) | ≤4.5% (Abs > 0.1) |
| Background Correction Capacity | >30× at ~1.0 Abs background |
| Measurement Mode | Dual-channel simultaneous detection |
| Power Input | 500 VA, AC 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions | 782 × 560 × 338 mm |
| Operating Environment | 10–30 °C, 0.070–0.106 MPa, vibration-free, non-corrosive, low-EMI |
| Brand | Bohui Innovation |
|---|---|
| Origin | Beijing, China |
| Model | BH2100S |
| Atomization Method | Tungsten-Boat Electrothermal AAS |
| Wavelength Range | 190–650 nm |
| Absorbance Range | 0–2 Abs |
| Baseline Stability (30 min preheat, 20 min measurement) | ≤0.009 A |
| Pb/Cd Sensitivity (≤50 µL) | ≥0.055 Abs (Pb), ≥0.025 Abs (Cd) |
| Precision (Abs > 0.1) | ≤4.5% (manual), <1% (with autosampler) |
| Background Correction Capacity | >30× at ~1.0 Abs |
| Power Input | 220 V ± 22 V, 50 Hz ± 1 Hz, 500 VA |
| Dimensions | 782 × 560 × 338 mm |
| Operating Environment | 10–30 °C, 0.070–0.106 MPa, vibration- and corrosion-free |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASAP |
| Pricing | Available Upon Request |
Show next