BrandBohui
OriginBeijing, China
ModelBH5100T
Analysis MethodFlame Atomic Absorption Spectrometry (FAAS)
Simultaneous Multi-Element DetectionCu, Zn, Ca, Mg, Fe
AtomizerPre-mixed 100 mm single-slit titanium burner
Wavelength Range190–650 nm
Spectral Bandwidth0.15–2.0 nm
Absorbance Range0–2 Abs
Baseline Stability≤0.005 Abs (30 min, unignited)
Characteristic Concentrations (Cu/Zn/Ca/Mg/Fe)≤0.035 / ≤0.015 / ≤0.080 / ≤0.040 / ≤1.05 mg/L per 1% absorption
Precision≤1.0% RSD (Abs > 0.1)
Sample Volume20 µL (Enhanced) or 40 µL (Standard) whole blood
Power SupplyAC 220 ± 22 V, 50 ± 1 Hz, 300 VA
Dimensions720 × 520 × 275 mm
Operating Environment10–30 °C, RH ≤70%, no vibration/corrosive gases/EMI
Safety ComplianceOverpressure Category II, integrated acetylene flashback arrestor, pressure/flow dual monitoring, automatic gas cutoff on power loss or low air pressure
SoftwareDedicated clinical data management system with GLP-compliant audit trail, automated calculation, storage, and report generation (graphical + tabular output)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBohui Innovation
OriginBeijing, China
ModelBH5500S
Analysis MethodFlame Atomic Absorption Spectrometry (FAAS)
Sample TypesWhole Blood, Serum, Breast Milk, Urine
Simultaneous Multi-Element DetectionCu, Zn, Ca, Mg, Fe
AtomizerPremixed 100 mm Single-Slit Titanium Burner
Wavelength Range190–650 nm
Spectral Bandwidth0.15–2.0 nm
Absorbance Range0–2 Abs
Baseline Stability≤0.005 Abs per 30 min (for Cu, Zn, Ca, Mg, Fe)
Precision≤1.0% RSD (Abs > 0.1)
Light SourcesComposite Hollow Cathode Lamps (Cu/Zn/Ca
MonochromatorHolographic Grating
NebulizerOptimized High-Efficiency Pneumatic Nebulizer
Nebulization ChamberPTFE-lined with Tapered Geometry and Rear Drain Design
Burner HeadPure Titanium
Safety SystemsAcetylene Anti-Flashback Valve, Pressure/Flow Dual Monitoring, Power-Fail Cut-off, Burner Explosion Protection
Power SupplyAC 220 ± 22 V, 50 ± 1 Hz, 300 VA
Dimensions782 × 560 × 338 mm
Operating Environment10–30 °C, RH ≤70%, Atmospheric Pressure 0.070–0.106 MPa, Vibration-Free & Corrosion-Free Ambient
SoftwareIntegrated Clinical FAAS Data Acquisition & Reporting Suite with Audit Trail Capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBohui Innovation
OriginBeijing, China
ModelBH5300S
Analysis MethodFlame Atomic Absorption Spectrometry (FAAS)
Sample TypesWhole Blood (40 µL) and Serum (300 µL)
Simultaneous Multi-Element DetectionCu, Zn, Ca, Mg, Fe
AtomizerPremixed 100 mm Single-Slit Titanium Burner
Absorbance Range0–2 Abs
Wavelength Range190–650 nm
Spectral Bandwidth0.15–2.0 nm
Light SourcesComposite Hollow Cathode Lamps (Cu/Zn/Ca
Baseline Stability≤0.005 Abs per 30 min
Characteristic Concentrations (Whole Blood)Cu ≤0.035 mg/L/%, Zn ≤0.015 mg/L/%, Ca ≤0.080 mg/L/%, Mg ≤0.040 mg/L/%, Fe ≤1.05 mg/L/%
Characteristic Concentrations (Serum)Cu ≤0.035 mg/L/%, Zn ≤0.020 mg/L/%, Ca ≤1.30 mg/L/%, Mg ≤0.20 mg/L/%, Fe ≤0.15 mg/L/%
Precision≤1.0% RSD (Abs > 0.1)
Safety ComplianceOverpressure Category II, Integrated Acetylene Anti-Flashback Valve, Air Pressure & Flow Monitoring, Power-Fail Flame Cutoff, Burner Explosion Protection
Power SupplyAC 220 ±22 V, 50 ±1 Hz, 300 VA
Dimensions782 × 560 × 338 mm
Operating Environment10–30 °C, RH ≤70%, Atmospheric Pressure 0.070–0.106 MPa, Vibration-Free, Corrosion- and EMI-Free
Show next