BrandBohui
OriginBeijing, China
ModelBH5100T
Analysis MethodFlame Atomic Absorption Spectrometry (FAAS)
Simultaneous Multi-Element DetectionCu, Zn, Ca, Mg, Fe
AtomizerPre-mixed 100 mm single-slit titanium burner
Wavelength Range190–650 nm
Spectral Bandwidth0.15–2.0 nm
Absorbance Range0–2 Abs
Baseline Stability≤0.005 Abs (30 min, unignited)
Characteristic Concentrations (Cu/Zn/Ca/Mg/Fe)≤0.035 / ≤0.015 / ≤0.080 / ≤0.040 / ≤1.05 mg/L per 1% absorption
Precision≤1.0% RSD (Abs > 0.1)
Sample Volume20 µL (Enhanced) or 40 µL (Standard) whole blood
Power SupplyAC 220 ± 22 V, 50 ± 1 Hz, 300 VA
Dimensions720 × 520 × 275 mm
Operating Environment10–30 °C, RH ≤70%, no vibration/corrosive gases/EMI
Safety ComplianceOverpressure Category II, integrated acetylene flashback arrestor, pressure/flow dual monitoring, automatic gas cutoff on power loss or low air pressure
SoftwareDedicated clinical data management system with GLP-compliant audit trail, automated calculation, storage, and report generation (graphical + tabular output)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBohui Innovation
OriginBeijing, China
ModelBH2200S
Analysis MethodGraphite Furnace Atomic Absorption Spectrometry (GFAAS)
Wavelength Range190–650 nm
Spectral Bandwidth0.10–2.0 nm
Absorbance Range0–2 Abs
Baseline Stability≤0.009 Abs/20 min (after 30-min warm-up)
Detection SensitivityPb > 0.055 Abs, Cd > 0.025 Abs (≤50 µL injection)
Precision≤2.9% RSD (Abs > 0.1)
Background Correction Capacity>30× at ~1.0 Abs
Signal MeasurementDual-channel simultaneous detection
Power SupplyAC 220 V, 50 Hz
Operating Temperature10–30 °C
Atmospheric Pressure0.070–0.106 MPa
Dimensions (Main Unit)782 × 560 × 338 mm
Dimensions (Graphite Furnace Power Supply)335 × 470 × 265 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBohui
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelBH400
PricingAvailable Upon Request
Detection PrincipleFluorescent Immunochromatography (Dual-Antibody Sandwich)
Assay FormatMultiplex Lateral Flow Immunoassay (LFIA)
Target AnalytesRotavirus, Enteric Adenovirus, Norovirus, Astrovirus
Measurement ModeQuantitative Fluorescence Intensity (Excitation/Emission Optimized for Europium Chelate or Similar Lanthanide Label)
Linear Range0–500 ng/mL (Fluorescein Reference Standard)
Background Noise<50 fluorescence units (10 consecutive blank test strip readings, mean)
Accuracy±5% of labeled value (fluorescein calibrator)
Precision (CV)≤10% at 100 ng/mL
Stability<5% signal drift within 20 min
Total Assay Time per Sample<30 s (instrument readout only
full assay including sample application and migration≤60 min)
Power SupplyAC 220 V, 50 Hz
Operating EnvironmentIndoor use
Dimensions (W×D×H)400 × 436 × 200 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBohui Innovation
OriginBeijing, China
ModelBH2101S
Analytical MethodTungsten-Boat Electrothermal Atomic Absorption Spectrometry (ETAAS)
Wavelength Range190–650 nm
Spectral Bandwidth1.0–2.0 nm
Absorbance Range0–2 Abs
Baseline Stability≤0.009 Abs/20 min (Pb & Cd, after 30-min preheating)
SensitivityPb >0.055 Abs, Cd >0.025 Abs (≤50 µL sample)
Precision≤4.5% RSD (Abs >0.1)
Background CorrectionSelf-reversal (self-absorption) method
Measurement ModeDual-channel simultaneous detection (Pb & Cd)
Power SupplyAC 220 V, 50 Hz, 600 VA
Dimensions780 × 560 × 470 mm (L×W×H)
Weight45 kg
Operating Environment10–30 °C, 0.070–0.106 MPa, vibration-free, non-corrosive, low-EMI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBohui Innovation
OriginBeijing, China
ModelBH5500S
Analysis MethodFlame Atomic Absorption Spectrometry (FAAS)
Sample TypesWhole Blood, Serum, Breast Milk, Urine
Simultaneous Multi-Element DetectionCu, Zn, Ca, Mg, Fe
AtomizerPremixed 100 mm Single-Slit Titanium Burner
Wavelength Range190–650 nm
Spectral Bandwidth0.15–2.0 nm
Absorbance Range0–2 Abs
Baseline Stability≤0.005 Abs per 30 min (for Cu, Zn, Ca, Mg, Fe)
Precision≤1.0% RSD (Abs > 0.1)
Light SourcesComposite Hollow Cathode Lamps (Cu/Zn/Ca
MonochromatorHolographic Grating
NebulizerOptimized High-Efficiency Pneumatic Nebulizer
Nebulization ChamberPTFE-lined with Tapered Geometry and Rear Drain Design
Burner HeadPure Titanium
Safety SystemsAcetylene Anti-Flashback Valve, Pressure/Flow Dual Monitoring, Power-Fail Cut-off, Burner Explosion Protection
Power SupplyAC 220 ± 22 V, 50 ± 1 Hz, 300 VA
Dimensions782 × 560 × 338 mm
Operating Environment10–30 °C, RH ≤70%, Atmospheric Pressure 0.070–0.106 MPa, Vibration-Free & Corrosion-Free Ambient
SoftwareIntegrated Clinical FAAS Data Acquisition & Reporting Suite with Audit Trail Capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBohui Innovation
OriginBeijing, China
ModelBH5300S
Analysis MethodFlame Atomic Absorption Spectrometry (FAAS)
Sample TypesWhole Blood (40 µL) and Serum (300 µL)
Simultaneous Multi-Element DetectionCu, Zn, Ca, Mg, Fe
AtomizerPremixed 100 mm Single-Slit Titanium Burner
Absorbance Range0–2 Abs
Wavelength Range190–650 nm
Spectral Bandwidth0.15–2.0 nm
Light SourcesComposite Hollow Cathode Lamps (Cu/Zn/Ca
Baseline Stability≤0.005 Abs per 30 min
Characteristic Concentrations (Whole Blood)Cu ≤0.035 mg/L/%, Zn ≤0.015 mg/L/%, Ca ≤0.080 mg/L/%, Mg ≤0.040 mg/L/%, Fe ≤1.05 mg/L/%
Characteristic Concentrations (Serum)Cu ≤0.035 mg/L/%, Zn ≤0.020 mg/L/%, Ca ≤1.30 mg/L/%, Mg ≤0.20 mg/L/%, Fe ≤0.15 mg/L/%
Precision≤1.0% RSD (Abs > 0.1)
Safety ComplianceOverpressure Category II, Integrated Acetylene Anti-Flashback Valve, Air Pressure & Flow Monitoring, Power-Fail Flame Cutoff, Burner Explosion Protection
Power SupplyAC 220 ±22 V, 50 ±1 Hz, 300 VA
Dimensions782 × 560 × 338 mm
Operating Environment10–30 °C, RH ≤70%, Atmospheric Pressure 0.070–0.106 MPa, Vibration-Free, Corrosion- and EMI-Free
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBohui Innovation
OriginBeijing, China
ModelBH2100T
Absorbance Range0–2 Abs
Wavelength Range190–650 nm
Baseline Stability≤0.009 A (after 30-min preheat, 20-min measurement)
Sensitivity (Pb)≥0.055 Abs at ≤50 µL
Sensitivity (Cd)≥0.025 Abs at ≤50 µL
Precision (Pb/Cd)≤4.5% (Abs > 0.1)
Background Correction Capacity>30× at ~1.0 Abs background
Measurement ModeDual-channel simultaneous detection
Power Input500 VA, AC 220 V ±10%, 50 Hz ±1 Hz
Dimensions782 × 560 × 338 mm
Operating Environment10–30 °C, 0.070–0.106 MPa, vibration-free, non-corrosive, low-EMI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBohui Innovation
OriginBeijing, China
ModelBH2100S
Atomization MethodTungsten-Boat Electrothermal AAS
Wavelength Range190–650 nm
Absorbance Range0–2 Abs
Baseline Stability (30 min preheat, 20 min measurement)≤0.009 A
Pb/Cd Sensitivity (≤50 µL)≥0.055 Abs (Pb), ≥0.025 Abs (Cd)
Precision (Abs > 0.1)≤4.5% (manual), <1% (with autosampler)
Background Correction Capacity>30× at ~1.0 Abs
Power Input220 V ± 22 V, 50 Hz ± 1 Hz, 500 VA
Dimensions782 × 560 × 338 mm
Operating Environment10–30 °C, 0.070–0.106 MPa, vibration- and corrosion-free
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBohui Innovation
OriginBeijing, China
ModelBH100
Detection PrincipleFluorescent Immunochromatography (Dual-Antibody Sandwich)
Assay Time<30 s per test
Linear Range0–500 ng/mL (fluorescein standard, r ≥ 0.990)
Background Noise<50 RFU (10× blank card avg.)
Accuracy±5% of labeled value (fluorescein calibrator)
PrecisionCV ≤10% at 100 ng/mL
Stability<5% fluorescence drift within 20 min
Power Supply220 V, 50 Hz
Operating Environment10–30 °C, ≤70% RH, altitude <2000 m
Dimensions400 × 436 × 200 mm