- All
- Favorite
- Popular
- Most rated
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | SRS-1000 T |
| CO₂ Range | 0–2000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Sensor Range | 0–3000 µmol·m⁻²·s⁻¹ |
| Soil Temperature Probe Range | 5–50 °C |
| Chamber Volume | 1 L |
| Chamber Diameter | 130 mm |
| Stainless Steel Collar Height | 75 mm |
| Acrylic Chamber Height | 70 mm |
| Operating Temperature | 5–45 °C |
| Battery Life | 10 h (2.8 Ah, 12 V lead-acid) |
| Display | 480 × 272 pixel WQVGA color touchscreen (95 × 53.9 mm) |
| Data Storage | SD card (up to 32 GB) |
| Interface | Mini-B USB & RS232 (9-pin D-sub) |
| Flow Rate | 68–340 µmol·m⁻²·s⁻¹ |
| Warm-up Time | 5 min @ 20 °C |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCpro T Portable Photosynthesis System |
| CO₂ Measurement Range | 0–3000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Measurement Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ (cosine-corrected) |
| Leaf/Chamber Temperature Range | −5 to 50 °C (±0.2 °C accuracy) |
| Airflow Rate | 100–500 mL·min⁻¹ |
| CO₂ Control | Up to 2000 ppm via internal supply |
| H₂O Control | Humidity adjustable above/below ambient |
| Temperature Control | Peltier-based, ±15 °C offset from ambient |
| PAR Control | White LED up to 2500 µmol·m⁻²·s⁻¹ |
| Weight | 4.1 kg (main unit), 0.8 kg (handheld sensor handle) |
| Battery Life | Up to 16 h (12 V, 7.5 Ah Li-ion) |
| Display | 95 × 53.9 mm WQVGA color touchscreen (80 × 272 px) |
| Data Storage | Removable SD card (up to 32 GB) |
| Communication | Mini-B USB + RS232 (max. 230,400 baud) |
| Operating Environment | 5–45 °C, high-humidity/dusty conditions supported |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | EGA60 |
| CO₂ Measurement Range | 0–2000 ppm |
| H₂O Vapor Pressure Range | 0–75 mbar |
| O₂ Measurement (Optional) | 0–50% (0–23 mg/L) |
| Flow Rate per Channel | 0–500 mL/min |
| Resolution | CO₂ = 1 ppm, H₂O = 0.1 mbar, O₂ = 0.05% @ 20% O₂ |
| Accuracy | CO₂ (temperature & pressure compensated), O₂ = ±0.2% @ 20% O₂ |
| Response Time (O₂) | <1 s |
| Data Storage | Removable SD card (up to 16 million data points) |
| Display | 240 × 64 pixel monochrome LCD |
| Operating Temperature | 5–45 °C |
| Dimensions | 27 × 25 × 15 cm |
| Weight | 7.5 kg |
| Interfaces | RS232, USB Mini-B, 7-channel analog input (0–5 V / 0–20 mA) |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AM350 Portable Leaf Area Meter |
| Price | Upon Request |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | APS Multi-Channel |
| Configuration Options | 5-channel or 10-channel modular system |
| Gas Exchange Measurement Principle | Infrared Gas Analysis (IRGA) with integrated multi-port gas multiplexer |
| Leaf Chamber Interface | Detachable, independently controlled cuvettes connected via extended pneumatic tubing and signal cables |
| Compliance | Designed for GLP-compliant environmental physiology studies |
| Software Platform | APS Control Suite with audit trail, timestamped raw data export (CSV/NetCDF), and optional FDA 21 CFR Part 11–ready configuration |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | iFL Portable |
| Pricing | Available Upon Request |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCi-T |
| CO₂ Measurement Range | 0–2000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Measurement Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ |
| Leaf & Chamber Temperature Range | −5 to 50 °C |
| Accuracy | ±0.2 °C |
| Airflow Rate | 68–340 mL/min |
| Flow Accuracy | ±2% of full scale |
| Preheat Time | 5 min at 20 °C |
| Data Storage | SD card (up to 32 GB, 16 million data points) |
| Display | 480 × 272-pixel color WQVGA touchscreen (95 × 53.9 mm) |
| Weight | 2.4 kg |
| Dimensions | 240 × 125 × 140 mm |
| Battery Life | ~10 h (12 V / 2.8 Ah lead-acid) |
| Operating Environment | 5–45 °C |
| GPS | Integrated |
| IRGA Type | Differential open-path, auto-zeroing with pressure & temperature compensation |
| H₂O Sensor | Dual-laser tunable diode absorption spectroscopy (TDLAS) |
| Fluorescence Module (optional) | Supports F₀, Fₘ, Fₘ′, QY_Ln, NPQ, OJIP-test (26 parameters), 100 kHz sampling rate |
| Brand | -- |
|---|---|
| Origin | Canada |
| Manufacturer Type | General Distributor |
| Import Status | Imported |
| Model | WinCELL |
| Pricing | Upon Request |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | ACE Automated Soil Respiration System |
| CO₂ Analyzer Resolution | 1 ppm |
| Chamber Area | 415 cm² |
| Power Options | 12 V 40 Ah Rechargeable Battery (≈30 days field operation), Solar Panel, or 220 V AC |
| Sensor Expansion | Up to 6 soil temperature probes, 4 soil moisture sensors |
| Measurement Modes | Closed-chamber (transparent & opaque), Open-chamber (transparent & opaque) |
| Data Storage | Internal SD card |
| Operating Interface | 240×64 pixel LCD with 5-button microcontroller interface |
| Optional Modules | Soil O₂ sensor, Hyperspectral imaging module, IR thermal imaging module, ECODRONE® UAV integration kit, Custom gas extraction/sampling configuration |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | ACE |
| Configuration | Master Control Unit + Up to 30 ACE Sensor Nodes |
| Power | Low-Voltage DC via Single Cable (No Pneumatic Tubing) |
| Max Network Radius | 200 m |
| Compliance | Designed for GLP-Compliant Field Deployment |
| Data Storage | Internal SD Card (No PC Required) |
| Interface | Local LCD + Keypad on Both Master and ACE Units |
| Optional Modules | O₂ Sensor, Hyperspectral Imaging Module, Thermal IR Imaging Module, ECODRONE® UAV Integration |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | SRS-2000 T |
| CO₂ Range | 0–3000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Sensor Range | 0–3000 µmol·m⁻²·s⁻¹ |
| Soil Temperature Probe Range | 5–50 °C |
| Chamber Volume | 1 L |
| Chamber Diameter | 130 mm |
| Chamber Height (Stainless Steel Ring + Acrylic Hood) | 145 mm |
| Flow Rate | 68–340 µmol·m⁻²·s⁻¹ |
| Preheat Time | 5 min @ 20 °C |
| Display | 480 × 272-pixel WQVGA color touchscreen (95 × 53.9 mm) |
| Battery | 7.5 Ah / 12 V Li-ion (16 h continuous operation) |
| Data Storage | SD card (up to 32 GB) |
| Operating Temperature | 5–45 °C |
| Control Unit Dimensions & Weight | 230 × 110 × 170 mm / 4.1 kg |
| Handle Weight | 0.8 kg |
| Chamber Weight | 645 g (325 g ring + 320 g hood) |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SCG-N |
| Price Range | USD 14,000–42,000 (FOB) |
| Instrument Type | Soil Moisture / Water Potential Analyzer |
| CO₂ Measurement Principle | NDIR (Non-Dispersive Infrared), Single-Beam Dual-Wavelength |
| Standard Depth Layers | 3 |
| Data Logger | 16-Channel (expandable to 32) |
| Power Supply | Rechargeable Li-ion Battery or Solar Panel |
| Wireless Connectivity | 4G LTE Full-Band Module (backward-compatible with EDGE/GPRS) |
| Compliance | Designed for GLP-aligned field research |
| Brand | -- |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FluorCam-WIC |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E-Series Field-Portable Tree Diagnostic Drill Probe |
| Pricing | Available Upon Request |
| Penetration Depth | 300/400 mm |
| Penetration Speed | 10–45 cm/min |
| Spatial Resolution | 0.1 mm |
| Data Storage Capacity | 256 KB (~20 m), 512 KB (~40 m), or 1 MB (~90 m) |
| Probe Lifetime | 200–300 insertions in softwood, 50–100 in hardwood |
| Data Output | Real-time thermal strip printing + USB download to PC |
| Charger Input | 110 V / 220 V AC |
| Battery | 7.2 V, 1.7 Ah / 2.0 Ah NiCd |
| Operating Temperature | 0–50 °C |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (PRC) |
| Model | PhenoTron® PTS |
| Pricing | Upon Request |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen Field |
| Key Features | Integrated chlorophyll fluorescence imaging (Fo, Fm, Fv/Fm, ΦPSII, NPQ, qP, qN, Rfd), RGB phenotyping (5 Mpx, leaf area, solidity, eccentricity, roundness, NDVI-equivalent greenness), thermal imaging (640×480 px, 7.5–13 µm, −20 to 120 °C), hyperspectral imaging (380–1000 nm, 675 bands), LiDAR 3D structural scanning, GPS-guided autonomous mobile platform (12 m arm span, 10 m swath, 2 cm positional accuracy), real-time data acquisition & cloud-enabled phenomics database (MySQL), daylight-adapted fluorometry with modulated 620 nm pulse light and 735 nm far-red actinic light, 720×560 px CCD (50 fps, 12-bit) or optional 1360×1024 px (20 fps, 16-bit), 35×35 cm standard imaging field (customizable to 80×80 cm) |
| Compliance | Designed for GLP-aligned field trials, supports ISO 22029 (plant phenotyping terminology), ASTM E2912 (spectral reflectance standards), and FAO/CGIAR phenotyping data interoperability guidelines |
| Brand | Delta-T |
|---|---|
| Origin | United Kingdom |
| Model | SM150T |
| Measurement Principle | Frequency Domain Reflectometry (FDR) |
| Soil Moisture Range | 0–0.7 m³·m⁻³ (standard), extendable to 0–1.0 m³·m⁻³ |
| Soil Moisture Accuracy | ±0.03 m³·m⁻³ (±3% vol.) |
| Soil Temperature Range | −20 to +60 °C |
| Temp. Accuracy | ±0.5 °C (0–40 °C), ±0.75 °C (−20 to +60 °C) |
| Electrical Conductivity Tolerance | 50–500 mS·m⁻¹ |
| EC-Induced Error | < ±0.035 m³·m⁻³ (for θ = 0.05–0.4 m³·m⁻³) |
| Output Signal | 0–1.0 V analog |
| Power Supply | 5–14 VDC, 18 mA @ 1 s sampling interval |
| IP Rating | IP68 |
| Operating Temperature | −40 to +70 °C |
| Sensing Volume | Ø70 mm × 55 mm cylinder |
| Probe Dimensions | 51 mm × Ø2.5 mm |
| Mass | 0.1 kg |
| Compatible Loggers | Delta-T GP1, GP2, DL2e, DL6 |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MultiScanner |
| Pricing | Available Upon Request |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HT-Respiro 24/96/240 Series |
| Pricing | Available Upon Request |
| Oxygen Measurement Range | 0–50% O₂ or 0–22.5 mg/L |
| Detection Limit | 0.15% O₂ (15 ppb DO) |
| Accuracy | ±1% at 20.9% O₂ |
| Resolution | ±0.4% at 20.9% O₂ or ±5 µmol at 283.1 µmol |
| Response Time | <30 s |
| Drift | <1% air saturation per week (10-min sampling interval) |
| Channel Capacity | Up to 240 parallel channels (10 × 24-channel readers) |
| Sensor Technology | Fluorescence-based optical oxygen sensing (REDFLASH for 96-well format) |
| Sample Chamber Material | Borosilicate glass (24-well) or sterile polystyrene (96-well) |
| Chamber Volume | 80–1700 µL (24-well) |
| Dimensions (per 24-channel reader) | 163 × 89 × 22 mm |
| Weight (per reader) | 380 g |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen SC |
| Mobility | Integrated casters for intra-greenhouse repositioning |
| Standard Plant Capacity | Up to 70 cm height, 50 cm canopy diameter |
| Core Imaging Modules | FluorCam chlorophyll fluorescence imaging + RGB 3D morphometric imaging |
| Optional Modules | 3D laser triangulation scanning, hyperspectral imaging (400–1000 nm), thermal infrared imaging (7.5–14 µm), NIR imaging |
| Sample Handling | Barcode-scanned standardized trays (5×4, 2×2, 1×2, 1×1 configurations |
| Environmental Monitoring | Integrated temperature & relative humidity sensors with time-synchronized logging |
| Software Suite | PSI PlantScreen Control & Analysis Suite (includes experiment scheduling, automated acquisition, batch processing, relational database management, GLP-compliant audit trail) |
| Brand | FMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Human Energy Metabolism Laboratory System |
| Price Range | USD 28,000 – 70,000 |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScan |
| Import Status | Imported |
| Type | Automated Plant Phenotyping System with Chlorophyll Fluorescence, RGB 3D, Thermal, NIR, and Hyperspectral Imaging |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | Fyto-Panel |
| Dimensions | 27 × 81 cm or 27 × 41 cm |
| Maximum Photosynthetic Photon Flux Density (PPFD) | 2400 µmol·m⁻²·s⁻¹ at 50 cm |
| Spectral Channels | Cool White + Far-Red + Deep Red (standard) |
| LED Lifetime | 60,000–70,000 h |
| Power Consumption | 210 W (A), 360 W (B), 580 W (C), 600 W (MULTI) |
| Operating Temperature | 0–55 °C |
| Relative Humidity | 0–80% RH (non-condensing) |
| Control Interface | USB/RS-485 |
| Software Features | Programmable light regimes (duration, intensity, spectral composition, modulation waveforms), cloud cover simulation, dawn/dusk transition modeling, GLP-compliant audit trail (via Light Studio Pro) |
Show next