BrandADC Bio
OriginUnited Kingdom
ModelLCpro T Portable Photosynthesis System
CO₂ Measurement Range0–3000 ppm
CO₂ Resolution1 ppm
H₂O Measurement Range0–75 mbar
H₂O Resolution0.1 mbar
PAR Range0–3000 µmol·m⁻²·s⁻¹ (cosine-corrected)
Leaf/Chamber Temperature Range−5 to 50 °C (±0.2 °C accuracy)
Airflow Rate100–500 mL·min⁻¹
CO₂ ControlUp to 2000 ppm via internal supply
H₂O ControlHumidity adjustable above/below ambient
Temperature ControlPeltier-based, ±15 °C offset from ambient
PAR ControlWhite LED up to 2500 µmol·m⁻²·s⁻¹
Weight4.1 kg (main unit), 0.8 kg (handheld sensor handle)
Battery LifeUp to 16 h (12 V, 7.5 Ah Li-ion)
Display95 × 53.9 mm WQVGA color touchscreen (80 × 272 px)
Data StorageRemovable SD card (up to 32 GB)
CommunicationMini-B USB + RS232 (max. 230,400 baud)
Operating Environment5–45 °C, high-humidity/dusty conditions supported
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADC Bio
OriginUnited Kingdom
ModelAPS Multi-Channel
Configuration Options5-channel or 10-channel modular system
Gas Exchange Measurement PrincipleInfrared Gas Analysis (IRGA) with integrated multi-port gas multiplexer
Leaf Chamber InterfaceDetachable, independently controlled cuvettes connected via extended pneumatic tubing and signal cables
ComplianceDesigned for GLP-compliant environmental physiology studies
Software PlatformAPS Control Suite with audit trail, timestamped raw data export (CSV/NetCDF), and optional FDA 21 CFR Part 11–ready configuration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADC Bio
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModeliFL Portable
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADC Bio
OriginUnited Kingdom
ModelLCi-T
CO₂ Measurement Range0–2000 ppm
CO₂ Resolution1 ppm
H₂O Measurement Range0–75 mbar
H₂O Resolution0.1 mbar
PAR Range0–3000 µmol·m⁻²·s⁻¹
Leaf & Chamber Temperature Range−5 to 50 °C
Accuracy±0.2 °C
Airflow Rate68–340 mL/min
Flow Accuracy±2% of full scale
Preheat Time5 min at 20 °C
Data StorageSD card (up to 32 GB, 16 million data points)
Display480 × 272-pixel color WQVGA touchscreen (95 × 53.9 mm)
Weight2.4 kg
Dimensions240 × 125 × 140 mm
Battery Life~10 h (12 V / 2.8 Ah lead-acid)
Operating Environment5–45 °C
GPSIntegrated
IRGA TypeDifferential open-path, auto-zeroing with pressure & temperature compensation
H₂O SensorDual-laser tunable diode absorption spectroscopy (TDLAS)
Fluorescence Module (optional)Supports F₀, Fₘ, Fₘ′, QY_Ln, NPQ, OJIP-test (26 parameters), 100 kHz sampling rate
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPSI (Czech Republic)
OriginCzech Republic
ModelFyto-Panel
Dimensions27 × 81 cm or 27 × 41 cm
Maximum Photosynthetic Photon Flux Density (PPFD)2400 µmol·m⁻²·s⁻¹ at 50 cm
Spectral ChannelsCool White + Far-Red + Deep Red (standard)
LED Lifetime60,000–70,000 h
Power Consumption210 W (A), 360 W (B), 580 W (C), 600 W (MULTI)
Operating Temperature0–55 °C
Relative Humidity0–80% RH (non-condensing)
Control InterfaceUSB/RS-485
Software FeaturesProgrammable light regimes (duration, intensity, spectral composition, modulation waveforms), cloud cover simulation, dawn/dusk transition modeling, GLP-compliant audit trail (via Light Studio Pro)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADC Bio
OriginUnited Kingdom
ModelLCpro T Intelligent Photosynthesis System
CO₂ Range0–2000 ppm
H₂O Control Range0–75 mbar
PAR SourceAdjustable RGB or White LED (0–2400 µmol·m⁻²·s⁻¹)
Temperature ControlPeltier-based (ΔT = +15 °C / −10 °C vs. ambient or ambient-follow mode)
GPSIntegrated with UTC time, latitude/longitude, and altitude logging
Humidity SensorsDual high-precision laser-trimmed capacitive sensors
IRGA DesignGold-coated, miniaturized, time-domain differential dual-beam NDIR for drift-free CO₂ measurement
Leaf Chamber Climate ControlSimultaneous closed-loop regulation of CO₂, H₂O, PAR, and temperature
Battery LifeUp to 16 h (Li-ion)
WeightControl Unit 4.1 kg, Measurement Unit 0.8 kg
Data StorageSD card + USB interface
Fluorescence IntegrationDirect hardware synchronization with FluorCam and portable chlorophyll fluorometers
ComplianceDesigned for GLP-aligned field data acquisition
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPSI (Czech Republic)
OriginCzech Republic
ModelFluorCam-96
Measurement PrincipleDual-modality chlorophyll fluorescence imaging + fiber-optic dissolved oxygen sensing
Throughput96 parallel samples
Fluorescence Parameters>50 including Fo, Fm, Fv/Fm, ΦPSII, NPQ, qL, ETR, Rfd, QY_Ln
Oxygen MeasurementFiber-optic sensor, ±0.1% O₂ @ 1% O₂, 0.01% O₂ resolution, 10–20 Hz sampling rate
Chamber MaterialSterilizable transparent polystyrene
Dimensions (O₂ module)162 × 102 × 32 mm
Weight (O₂ module)670 g
Temperature Sensor0–50 °C, ±0.5 °C accuracy, 0.012 °C resolution
Pressure Sensor300–1100 mbar, ±6 mbar accuracy, 0.11 mbar resolution
SoftwareFluorCam v7.x with GLP-compliant audit trail, protocol editor, ROI-based kinetic analysis, signal averaging mode for low-biomass samples