- All
- Favorite
- Popular
- Most rated
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCpro T Portable Photosynthesis System |
| CO₂ Measurement Range | 0–3000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Measurement Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ (cosine-corrected) |
| Leaf/Chamber Temperature Range | −5 to 50 °C (±0.2 °C accuracy) |
| Airflow Rate | 100–500 mL·min⁻¹ |
| CO₂ Control | Up to 2000 ppm via internal supply |
| H₂O Control | Humidity adjustable above/below ambient |
| Temperature Control | Peltier-based, ±15 °C offset from ambient |
| PAR Control | White LED up to 2500 µmol·m⁻²·s⁻¹ |
| Weight | 4.1 kg (main unit), 0.8 kg (handheld sensor handle) |
| Battery Life | Up to 16 h (12 V, 7.5 Ah Li-ion) |
| Display | 95 × 53.9 mm WQVGA color touchscreen (80 × 272 px) |
| Data Storage | Removable SD card (up to 32 GB) |
| Communication | Mini-B USB + RS232 (max. 230,400 baud) |
| Operating Environment | 5–45 °C, high-humidity/dusty conditions supported |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | APS Multi-Channel |
| Configuration Options | 5-channel or 10-channel modular system |
| Gas Exchange Measurement Principle | Infrared Gas Analysis (IRGA) with integrated multi-port gas multiplexer |
| Leaf Chamber Interface | Detachable, independently controlled cuvettes connected via extended pneumatic tubing and signal cables |
| Compliance | Designed for GLP-compliant environmental physiology studies |
| Software Platform | APS Control Suite with audit trail, timestamped raw data export (CSV/NetCDF), and optional FDA 21 CFR Part 11–ready configuration |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | iFL Portable |
| Pricing | Available Upon Request |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCi-T |
| CO₂ Measurement Range | 0–2000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Measurement Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ |
| Leaf & Chamber Temperature Range | −5 to 50 °C |
| Accuracy | ±0.2 °C |
| Airflow Rate | 68–340 mL/min |
| Flow Accuracy | ±2% of full scale |
| Preheat Time | 5 min at 20 °C |
| Data Storage | SD card (up to 32 GB, 16 million data points) |
| Display | 480 × 272-pixel color WQVGA touchscreen (95 × 53.9 mm) |
| Weight | 2.4 kg |
| Dimensions | 240 × 125 × 140 mm |
| Battery Life | ~10 h (12 V / 2.8 Ah lead-acid) |
| Operating Environment | 5–45 °C |
| GPS | Integrated |
| IRGA Type | Differential open-path, auto-zeroing with pressure & temperature compensation |
| H₂O Sensor | Dual-laser tunable diode absorption spectroscopy (TDLAS) |
| Fluorescence Module (optional) | Supports F₀, Fₘ, Fₘ′, QY_Ln, NPQ, OJIP-test (26 parameters), 100 kHz sampling rate |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | Fyto-Panel |
| Dimensions | 27 × 81 cm or 27 × 41 cm |
| Maximum Photosynthetic Photon Flux Density (PPFD) | 2400 µmol·m⁻²·s⁻¹ at 50 cm |
| Spectral Channels | Cool White + Far-Red + Deep Red (standard) |
| LED Lifetime | 60,000–70,000 h |
| Power Consumption | 210 W (A), 360 W (B), 580 W (C), 600 W (MULTI) |
| Operating Temperature | 0–55 °C |
| Relative Humidity | 0–80% RH (non-condensing) |
| Control Interface | USB/RS-485 |
| Software Features | Programmable light regimes (duration, intensity, spectral composition, modulation waveforms), cloud cover simulation, dawn/dusk transition modeling, GLP-compliant audit trail (via Light Studio Pro) |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCpro T Intelligent Photosynthesis System |
| CO₂ Range | 0–2000 ppm |
| H₂O Control Range | 0–75 mbar |
| PAR Source | Adjustable RGB or White LED (0–2400 µmol·m⁻²·s⁻¹) |
| Temperature Control | Peltier-based (ΔT = +15 °C / −10 °C vs. ambient or ambient-follow mode) |
| GPS | Integrated with UTC time, latitude/longitude, and altitude logging |
| Humidity Sensors | Dual high-precision laser-trimmed capacitive sensors |
| IRGA Design | Gold-coated, miniaturized, time-domain differential dual-beam NDIR for drift-free CO₂ measurement |
| Leaf Chamber Climate Control | Simultaneous closed-loop regulation of CO₂, H₂O, PAR, and temperature |
| Battery Life | Up to 16 h (Li-ion) |
| Weight | Control Unit 4.1 kg, Measurement Unit 0.8 kg |
| Data Storage | SD card + USB interface |
| Fluorescence Integration | Direct hardware synchronization with FluorCam and portable chlorophyll fluorometers |
| Compliance | Designed for GLP-aligned field data acquisition |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam-96 |
| Measurement Principle | Dual-modality chlorophyll fluorescence imaging + fiber-optic dissolved oxygen sensing |
| Throughput | 96 parallel samples |
| Fluorescence Parameters | >50 including Fo, Fm, Fv/Fm, ΦPSII, NPQ, qL, ETR, Rfd, QY_Ln |
| Oxygen Measurement | Fiber-optic sensor, ±0.1% O₂ @ 1% O₂, 0.01% O₂ resolution, 10–20 Hz sampling rate |
| Chamber Material | Sterilizable transparent polystyrene |
| Dimensions (O₂ module) | 162 × 102 × 32 mm |
| Weight (O₂ module) | 670 g |
| Temperature Sensor | 0–50 °C, ±0.5 °C accuracy, 0.012 °C resolution |
| Pressure Sensor | 300–1100 mbar, ±6 mbar accuracy, 0.11 mbar resolution |
| Software | FluorCam v7.x with GLP-compliant audit trail, protocol editor, ROI-based kinetic analysis, signal averaging mode for low-biomass samples |