Empowering Scientific Discovery

Beijing Hope Century Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelENDA-640ZG Series
Instrument TypeFlue Gas CEMS
Accuracy±1.0% F.S.
Repeatability±0.5% F.S.
Response Time (SO₂)60–240 s
Stability±2.0% F.S./week
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelTCA-51d / TCA-51p
Explosion ProtectionEx d IIB+H2 T4 / Ex px d IIC T4X
Detection PrincipleThermal Conductivity
MeasurandsH₂, O₂
Range0–10 to 0–100 vol% (H₂), 0–5 to 0–25 vol% (O₂)
Repeatability±0.5% F.S. (standard range)
Linearity±1.0% F.S.
Zero Drift±1.0% F.S./week (standard range)
Span Drift±2.0% F.S./week (standard range)
Response Time (T90)≤20 s
Sample Flow Rate300–1500 mL/min
Operating Pressure≥1.98 kPa (TCA-51d), ≥14.7 kPa (TCA-51p)
Wetted MaterialsSUS304, SUS316, FKM, Pt, Au, SiO₂, Borosilicate Glass
ComplianceIEC 60079-0, IEC 60079-1 (Ex d), IEC 60079-2 (Ex p), ATEX Directive 2014/34/EU, UKCA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelAPNA-370(G)
Instrument TypeOnline Continuous Emission Monitor
Measured GasesNitric Oxide (NO), Nitrogen Dioxide (NO₂), Total Nitrogen Oxides (NOₓ)
Response Time (T90)≤120 s
Detection Limit0.5 ppb (2σ, ≤0.2 ppm range) / 1.0% F.S. (2σ, >0.2 ppm range)
Measurement Range0–10 ppm (4 selectable sub-ranges, max span ratio 10:1)
Accuracy±1.0% F.S. (linearity & repeatability)
Zero Drift±1.0 ppb/day or ±1.0% F.S./day (whichever greater)
Span Drift±1.0% F.S./day
Sample Flow Rate~0.8 L/min
Operating Temperature5–40 °C
Power Supply100–240 VAC, 50/60 Hz
Dimensions430 × 550 × 221 mm (W×D×H)
Weight~21 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelOCMA-550
Instrument TypePortable
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption with S-316 Solvent Extraction
Measurement Range0–200 mg/L (water), 0–1000 mg/kg (soil), 0–1 Abs
Detection Limit0.1 ppm
Repeatability±0.4 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L), ±1% F.S. (0–1 Abs)
Optical PathQuartz Cuvette (200 mm path length)
DetectorThermoelectric Sensor
DisplayBacklit LCD with Timestamp
InterfaceRS-232C, Parallel Printer Port
Power Supply230 V AC, 50 Hz
Dimensions250 × 200 × 285 mm (W × H × D)
Standard AccessoriesCovered quartz cuvette, power cord, heavy oil standard (B-grade), 2 A fuse, 10 mL and 25 µL syringes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelAPMA-370
Instrument TypePortable Gas Analyzer
Detection TargetSingle-component (CO)
Measurement Range0–5 / 0–10 / 0–20 / 0–50 ppm (selectable)
Repeatability±1.0% F.S.
Response Time (T90)≤60 s (at lowest range)
Zero Drift±0.1 ppm/day or ±1.0% F.S./day (whichever is greater)
Span Drift±2.0% F.S./day or ±3.0% F.S./week
Linearity Error±1.0% F.S.
Detection Limit0.05 ppm (2σ, for ranges ≤10 ppm)
Sample Flow Rate~1.5 L/min
Operating Temperature5–40 °C
Power Supply100–240 VAC, 50/60 Hz
Dimensions430 × 550 × 221 mm (W×D×H)
Weight~16 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelIT-230
Temperature Range0–300 °C
OutputAnalog (4–20 mA or 0–10 V selectable)
Alarm OutputsDual independent relay outputs
MountingBenchtop / Fixed-installation compatible
ComplianceCE marked, RoHS compliant
Enclosure RatingIP65 (front panel)
Show next