Empowering Scientific Discovery

Beijing Huayirui Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelMQ500
Measurement Uncertainty±5%
Measurement Range0–4000 µmol·m⁻²·s⁻¹
Long-term Drift<2% per year
Repeatability<0.5%
Nonlinearity<1%
Response Time<1 ms
Field of View180°
Spectral Range389–692 nm ±5 nm
Spectral Selectivity<10% (412–692 nm ±5 nm)
Azimuthal Error<0.5%
Tilt Error<0.5%
Temperature Response−0.11±0.04 %·°C⁻¹
Ingress Protection RatingIP68
Dimensions24 mm (diameter) × 37 mm (height)
Mass100 g (including 5 m cable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelSK01-DP2
Spectral Range400–700 nm
Output Sensitivity0.5 mV per μmol·s⁻¹·m⁻²
Measurement Range0–3000 μmol·s⁻¹·m⁻²
Response Time (95%)30 ms
Long-Term Drift (per year)< ±2%
Nonlinearity< ±1%
Directional Response (30°–80° zenith angle)< ±30 W·m⁻² (ISO 9060 Class II compliant)
Temperature Response< ±0.15% per °C
Operating Temperature−35 to +60 °C
Power Supply5.5–14.5 VDC, 3 mA
HousingAnodized aluminum, IP67 rated
Cable Length3 m
Weight0.3 kg
Dimensions (L×W×H)150 × 150 × 150 mm
Calibration Uncertainty±3%
Spectral Responsivity Match (vs. CIE PAR action spectrum)±6% (overcast) to +2% (thin cloud)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelSS-120
Spectral Range635–1100 nm
Spectral Sampling Interval1.0 nm
Spectral Resolution3.0 nm
Spectral Accuracy±0.5 nm
Spectral Repeatability±0.2 nm
A/D Conversion14-bit
Signal-to-Noise Ratio1500:1
Stray Light≤0.25% at 850 nm
Noise Level≤3 counts
Integration Time10 ms – 10 s
Linearity<1% or 0.5%
Quantum Efficiency>10% (λ < 1030 nm)
Radiometric Repeatability<1% (λ < 1020 nm)
Cosine Response Error±5% at 75° zenith angle
Field of View25° or 150° (downward-facing configuration)
Operating Temperature−20 to +70 °C
Relative Humidity0–100% RH
Power Consumption1 W (USB-powered)
Current Draw190 mA
Weight300 g
Dimensions89.3 × 50.8 × 38.1 mm (H × W × L)
Communication InterfaceUSB
Software CompatibilityWindows XP and later
Irradiance Calibration Uncertainty±5%
Temperature Coefficient−0.1 ± 0.1 %/°C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee Instruments
OriginUSA
ModelPS-300
Spectral Range220–1100 nm
Wavelength Resolution1.5 nm
Detector2048-pixel CCD
GratingHolographic, aberration-corrected, 590 g/mm
A/D Converter16-bit
Signal-to-Noise Ratio1000:1
Stray Light≤0.02% @ 435 nm, ≤0.2% @ 200 nm
Measurement Repeatability<1%
Irradiance Calibration Uncertainty±10% (300–1000 nm)
Cosine Response Error±5% up to 80° zenith angle
Integration Time1 ms – 65 s
InterfaceUSB 2.0
Power5 VDC, 100 mA (bus-powered)
Operating Temperature0–60 °C
Fiber Optic Cable2 m armored silica fiber
Dimensions69 × 100 × 150 mm
Weight900 g
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelFM-120
Measurement Range2–50 µm
Sampling Area0.24 mm²
Volumetric Flow Rate1 m³/min
Sampling FrequencyAdjustable from 0.04 s to 20 s
Refractive Index Assumption1.33 (non-absorbing, water standard)
Scattering Collection Angle3.5°–12° (annular forward cone)
Operating Temperature0–40 °C
Relative Humidity0–100 % RH (non-condensing)
Altitude Limit≤ 4,000 m
Instrument Weight10.0 kg
External Pump Weight9.5 kg
Dimensions (Detector Unit)23 cm (W) × 37 cm (L) × 28 cm (H)
Power SupplyFM-120 unit: 85–264 VAC, 50–60 Hz
External pump220 VAC
Data InterfaceRS-422 or RS-232
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China-made)
ModelPARNet
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelO3-LIDAR
Laser SourceNd:YAG-based UV laser system (266 nm fundamental, 289 nm & 316 nm Raman-shifted)
DetectorHigh-quantum-efficiency photomultiplier tubes (PMTs) with solar-blind UV response
Operating Wavelengths289 nm and 316 nm (DIAL pair)
Maximum Detection AltitudeUp to 25 km (dependent on atmospheric conditions)
Pulse Repetition Frequency20–50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeDistributor
Origin CategoryImported
ModelPortable
Price RangeUSD 1,400 – 7,200 (est.)
Laser SourcePulsed Solid-State Nd:YAG (1064 nm)
DetectorHigh-Sensitivity Avalanche Photodiode (APD) Array
Operating Wavelength1064 nm
Maximum Detection Altitude8 km (a.s.l.)
Pulse Repetition Frequency4 kHz
Spatial ResolutionAdjustable (7.5 m / 15 m / 30 m)
Laser Safety ClassClass 3B (IEC 60825-1)
Enclosure RatingIP65
Power Supply220 V AC or 12 V DC (battery-compatible)
Scan MechanismIntegrated European-Made 3D Galvanometric Motor (±90° azimuth, ±45° elevation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelSGR3
Spectral Range4.4–50 µm
Response Time<18 s
Zero Offset (B)<5 W/m²
Temperature Dependence of Sensitivity (−20 to +50 °C)<3%
Operating Temperature Range−40 to +80 °C
Field of View150°
Analog Output4–20 mA or 0–1 V per W/m²
Window Heating Offset15 W/m²
Power Supply5–30 VDC
Communication InterfaceRS-485 Modbus®
Desiccant Replacement Interval≥10 years
Directional Error<5 W/m²
Temperature Correction Range−40 to +80 °C
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
ModelHC2-S3
PricingAvailable Upon Request
Temperature Sensing ElementPt100 RTD (IEC 60751 Class B, 1/3 tolerance)
Temp. Range−40 to +60 °C
Temp. Accuracy±0.1 K at 23 °C (standard)
Humidity Range0–100 % RH
RH Accuracy±0.8 % RH (3-point calibration: 10, 35, 80 % RH) / ±0.5 % RH (9-point calibration: 10–90 % RH in 10 % steps)
Operating Environment−50 to +100 °C, 0–100 % RH
Supply Voltage3.2–5 VDC or 12 VDC
Output Signal0–1 VDC analog voltage
ConnectorStainless steel military-grade aviation connector (MIL-C-5015 compliant)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeDistributor
ModelHBW Series
PricingUpon Request
Accuracy ClassA (±0.1 °C), B (±0.2 °C to ±0.3 °C)
Measurement RangeHBW-1: −50 °C to +50 °C
HBW-2−50 °C to +80 °C
Sensor ElementIEC 60751-compliant Pt100 (α = 0.00385 Ω/Ω/°C)
Configuration4-wire RTD
CableShielded 4-core, standard 10 m (custom lengths available)
Probe Dimensions70 mm sheath length, 4 mm sensing tip diameter, 10 mm sheath OD
Mass0.35 kg (including 10 m cable)
Calibration Interval2 years
ComplianceIEC 60751:2022, EN 60751, ASTM E1137/E1137M
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRM Young
OriginUSA
Model41342
Sensor Type1000 Ω Pt RTD (Class A)
Output Options4-wire Pt RTD / 0–1 VDC (5 mA, 8–24 VDC supply) / 4–20 mA (20 mA, 12–30 VDC supply)
Temperature Range–50 to +50 °C
Calibration Accuracy at 0 °C±0.3 °C (NIST-traceable certificate included)
Optional Enhanced Accuracy±0.1 °C
Recommended Radiation ShieldsGill 41003P Passive Multi-Plate Shield or 43502 Active Ventilated Shield
ComplianceNIST-traceable calibration, ISO/IEC 17025-compliant calibration procedures
Added to wishlistRemoved from wishlist 0
Add to compare
Measurement Range-30 °C to 1100 °C
Accuracy±0.5 °C
Resolution1 °C
Repeatability±1 °C
Spectral Band8–14 µm
Optical Field of ViewStandard 2° or 15°, optional 60°
Emissivity Adjustment0.2–0.98 (user-selectable via rear panel)
Response Time0.1 s
Operating Ambient Temperature-10 °C to 50 °C, ≤99% RH (non-condensing)
Storage Temperature-10 °C to 50 °C
Lens MaterialDual-coated zinc selenide (ZnSe), MIL-C-13508 compliant
Output SignalRS-232C standard, optional 1 mV/°C analog output
Power SupplyRechargeable NiCd battery, 40 h continuous operation
Battery Charger120 V/60 Hz/3 W or 230 V/50 Hz optional
Minimum Measurement Distance2 cm
Maximum Measurement Distance300 m
HousingStainless steel
OriginImported
Manufacturer TypeDistributor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCampbell Scientific
ModelTM320
OriginUSA
Temperature Range−20 to 70 °C
Temperature Accuracy±0.5 °C
Relative Humidity Range0 to 95 %RH (non-condensing)
RH Accuracy±2 %RH
Operating Environment−20 to 70 °C
Power Supply4 × AA alkaline batteries or optional AC adapter
Memory Capacity32,000 data points
Sampling IntervalAdjustable from 1 second to 24 hours (in 10-second increments)
Alarm FunctionUser-configurable high/low limits with audible alert
Housing MaterialPolycarbonate
Dimensions10.2 × 7.7 × 3.9 cm
Weight255 g (9 oz)
CertificationsCE
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0