| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | HC2-S3 |
| Pricing | Available Upon Request |
| Temperature Sensing Element | Pt100 RTD (IEC 60751 Class B, 1/3 tolerance) |
| Temp. Range | −40 to +60 °C |
| Temp. Accuracy | ±0.1 K at 23 °C (standard) |
| Humidity Range | 0–100 % RH |
| RH Accuracy | ±0.8 % RH (3-point calibration: 10, 35, 80 % RH) / ±0.5 % RH (9-point calibration: 10–90 % RH in 10 % steps) |
| Operating Environment | −50 to +100 °C, 0–100 % RH |
| Supply Voltage | 3.2–5 VDC or 12 VDC |
| Output Signal | 0–1 VDC analog voltage |
| Connector | Stainless steel military-grade aviation connector (MIL-C-5015 compliant) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | HBW Series |
| Pricing | Upon Request |
| Accuracy Class | A (±0.1 °C), B (±0.2 °C to ±0.3 °C) |
| Measurement Range | HBW-1: −50 °C to +50 °C |
| HBW-2 | −50 °C to +80 °C |
| Sensor Element | IEC 60751-compliant Pt100 (α = 0.00385 Ω/Ω/°C) |
| Configuration | 4-wire RTD |
| Cable | Shielded 4-core, standard 10 m (custom lengths available) |
| Probe Dimensions | 70 mm sheath length, 4 mm sensing tip diameter, 10 mm sheath OD |
| Mass | 0.35 kg (including 10 m cable) |
| Calibration Interval | 2 years |
| Compliance | IEC 60751:2022, EN 60751, ASTM E1137/E1137M |
| Brand | RM Young |
|---|---|
| Origin | USA |
| Model | 41342 |
| Sensor Type | 1000 Ω Pt RTD (Class A) |
| Output Options | 4-wire Pt RTD / 0–1 VDC (5 mA, 8–24 VDC supply) / 4–20 mA (20 mA, 12–30 VDC supply) |
| Temperature Range | –50 to +50 °C |
| Calibration Accuracy at 0 °C | ±0.3 °C (NIST-traceable certificate included) |
| Optional Enhanced Accuracy | ±0.1 °C |
| Recommended Radiation Shields | Gill 41003P Passive Multi-Plate Shield or 43502 Active Ventilated Shield |
| Compliance | NIST-traceable calibration, ISO/IEC 17025-compliant calibration procedures |
| Measurement Range | -30 °C to 1100 °C |
|---|---|
| Accuracy | ±0.5 °C |
| Resolution | 1 °C |
| Repeatability | ±1 °C |
| Spectral Band | 8–14 µm |
| Optical Field of View | Standard 2° or 15°, optional 60° |
| Emissivity Adjustment | 0.2–0.98 (user-selectable via rear panel) |
| Response Time | 0.1 s |
| Operating Ambient Temperature | -10 °C to 50 °C, ≤99% RH (non-condensing) |
| Storage Temperature | -10 °C to 50 °C |
| Lens Material | Dual-coated zinc selenide (ZnSe), MIL-C-13508 compliant |
| Output Signal | RS-232C standard, optional 1 mV/°C analog output |
| Power Supply | Rechargeable NiCd battery, 40 h continuous operation |
| Battery Charger | 120 V/60 Hz/3 W or 230 V/50 Hz optional |
| Minimum Measurement Distance | 2 cm |
| Maximum Measurement Distance | 300 m |
| Housing | Stainless steel |
| Origin | Imported |
| Manufacturer Type | Distributor |
| Brand | Campbell Scientific |
|---|---|
| Model | TM320 |
| Origin | USA |
| Temperature Range | −20 to 70 °C |
| Temperature Accuracy | ±0.5 °C |
| Relative Humidity Range | 0 to 95 %RH (non-condensing) |
| RH Accuracy | ±2 %RH |
| Operating Environment | −20 to 70 °C |
| Power Supply | 4 × AA alkaline batteries or optional AC adapter |
| Memory Capacity | 32,000 data points |
| Sampling Interval | Adjustable from 1 second to 24 hours (in 10-second increments) |
| Alarm Function | User-configurable high/low limits with audible alert |
| Housing Material | Polycarbonate |
| Dimensions | 10.2 × 7.7 × 3.9 cm |
| Weight | 255 g (9 oz) |
| Certifications | CE |