Beijing Junfang Lihua Science & Technology Research Institute

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGXH-1050E
Instrument TypeOnline Process Analyzer
Detection TargetMulti-component Gases
Minimum Range0–50 ppm
Repeatability≤1% F.S.
Resolution0.1 ppm
Response Time≤60 s
Zero Drift≤±2% F.S./24 h
Span Drift≤±2% F.S./24 h
Linearity Error≤±1% F.S.
Power SupplyAC 220 V ±10%, 50 Hz ±5%
Output Signal4–20 mA analog + RS232 digital interface
Operating Humidity≤90% RH (non-condensing)
Warm-up Time≤60 min
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelJF-3000
PriceUpon Request
Measurement RangeCO: 0–5% vol, O₂: 0–10% vol
Alarm Setpoint Range10–90% of Full Scale
Zero Drift≤ ±1% FS (after 8-hr warm-up, 48-hr continuous operation)
Sensitivity Drift≤ ±1% FS
Temperature Influence≤ 3% FS over 5–40°C
Response Time (T₉₀)≤ 2 min
Sample Flow Rate0.5 L/min
Output Relay Capacity220 V AC / 5 A
Dimensions1800 × 610 × 700 mm
Weight~180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
OriginBeijing, China
ModelHXPQX-500
Internal Volume500 L
Cross-sectional Dimensions460 mm × 400 mm
Centerline Length of Wind Tunnel945 mm
Airflow Velocity Range0–7 m/s ±0.2 m/s (adjustable via frequency converter)
Preset Airflow Setpoints0.8, 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 6.5 m/s
Control Interface7-inch TFT touch LCD panel
Rotation Capability360° continuous
Power Consumption≤2 kW
Supply Voltage3N 380 V, 50 Hz
External Dimensions2094 mm × 568 mm × 1034 mm
Exhaust SystemAutomated gas purging
CommunicationRS485 / RS232, MODBUS-RTU protocol, multi-channel digital output interfaces
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelGXH-3051C
PricingAvailable Upon Request
CO₂ Resolution0.1 ppm
CO₂ Range0–1000 ppm
CO₂ Accuracy±1% F.S.
Relative Humidity Resolution0.1% RH
RH Range0–100% RH
RH Accuracy±2% F.S.
Temperature Resolution0.1 °C
Temp Range0–50 °C
Temp Accuracy±0.2 °C
Photosynthetic Photon Flux Density (PPFD) Resolution1 µmol·m⁻²·s⁻¹
PPFD Range0–3000 µmol·m⁻²·s⁻¹
PPFD Accuracy±10 µmol·m⁻²·s⁻¹
Battery6 V, 4 Ah Ni-MH
Continuous Operation Time≥2 h (instrument), ≥3 h (laptop)
Charging220 V AC, 12 h full charge
Airline Length1.2 m
Net Weight2.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMSR (Msfang Li Hua)
OriginBeijing, China
ModelGXH-1051L
Instrument TypeOnline Gas Analyzer
Measured GasCO (Carbon Monoxide)
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Range0–50 ppm (standard), customizable up to 0–100% vol
Repeatability≤ ±1% FS
Linearity Error≤ ±2% FS
Zero Drift≤ ±1% FS / 48 h
Span Drift≤ ±1% FS / 48 h
Response Time (T90)≤ 30 s
Resolution0.1 ppm (minimum)
Warm-up Time≤ 60 min
Operating Humidity≤ 90% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50 Hz ±5%
Output Signal4–20 mA analog
Sample PumpIntegrated diaphragm pump
EnclosureRack-mountable embedded chassis
Temperature ControlInternal thermostatic stabilization
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
OriginBeijing, China
ModelJFQ-3150L
PrincipleNon-Dispersive Infrared (NDIR) Absorption
TypePortable
Response Time≤30 s
Repeatability≤±1% FS
Zero Drift≤±2% FS / 4 h
Span Drift≤±2% FS / 4 h
Linearity≤±2% FS
Warm-up Time15 min
Measurable GasesCO₂, CO, CH₄, SO₂, NO, NO₂, H₂S
Measurement RangesCO₂ & CO — 0–50 ppm to 0–100% (configurable per application)
ComplianceDesigned for field-deployable environmental and occupational hygiene monitoring per ISO 12039, ISO 21258, and EPA Method TO-11A guidelines
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Chemical & Physical
OriginBeijing, China
ModelJF-2200
Measurement GasesCH₄, C₃H₈, CO, H₂
Accuracy±2% FS
Warm-up Time30 min
OutputRS232 digital interface, 4–20 mA analog output
Power SupplyAC 220 V or DC 12 V
Multi-channel CapabilityUp to 20 gas alarm units
Data StorageInternal high-capacity non-volatile memory
CommunicationRS-232C serial interface
CustomizationAdjustable measurement range per user specification
ComplianceDesigned for alignment with GB 50493, JJG 693, and ISO 16000-24 calibration verification protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
ModelGXH-1052E
OriginBeijing, China
Instrument TypeOnline Fixed-Mount Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Measured GasCO₂ (Single-Component)
Range0–500 ppm (standard)
Resolution0.1 ppm
Repeatability≤1% FS
Linearity Error≤±1% FS/24h
Zero Drift≤±2% FS/24h
Span Drift≤±2% FS/24h
Response Time (T₉₀)≤60 s
Power SupplyAC 220 V ±10%, 50 Hz ±5%
Output Signals4–20 mA analog + RS232 digital interface
Operating Humidity≤90% RH (non-condensing)
Warm-up Time≤60 min
Internal Sampling PumpIntegrated
DisplayBacklit LCD with touch interface
Data LoggingOnboard memory + PC software export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
OriginBeijing, China
ModelJFQ-1150L
Measurement PrincipleNDIR with optional thermal conductivity, electrochemical, or fluorescence detection modules
Gas ChannelsSingle-channel configurable
Measurable GasesCH₄, C₃H₈, total hydrocarbons (HC), H₂, O₂, H₂S, SO₂, NH₃ (gas-specific module dependent)
Range0–100% vol (field-configurable)
Linearity Error≤ ±2% FS
Repeatability≤ ±1% FS
Zero Drift≤ ±1% FS / 48 h
Span Drift≤ ±1% FS / 48 h
Warm-up Time≤ 60 min
Response Time (T₉₀)≤ 60 s
Operating Humidity≤ 90% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50 Hz ±5%
Output Signal4–20 mA analog
EnclosureRack-mountable embedded chassis with integrated sampling pump
Internal Temperature ControlYes
ComplianceDesigned to meet GB/T 16157, HJ 75–2017, HJ 76–2017, and ISO 12039 requirements for continuous emission monitoring systems (CEMS)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Physical Chemistry
OriginBeijing, China
ModelJF-2300
Operating Temperature0–50 °C
Relative Humidity40–90 % RH
Power SupplyAC 220 V ±10 %, 50 Hz
Gas Mixing Accuracy±1 % of set value
Concentration Range0–100 % (adjustable continuously)
Repeatability≤0.5 %
Stability≤±1 % F.S.
Linearity Error≤±1 % of set value
Response Time≤5 s
Flow Rate0.5–1.0 L/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Physical & Chemical
OriginBeijing, China
ModelJF-3000
Instrument TypeOnline Analyzer
Detection TargetMulti-component Gases
Minimum Full-Scale Accuracy≤±1% F.S.
Repeatability≤±1% F.S.
Resolution0.1 ppm
Response Time≤30 s
Zero Drift≤±1% F.S.
Span Drift≤±1% F.S.
Linearity Error≤±1% F.S.
Sample Flow Rate0.5 L/min
Operating Ambient Temperature Range5–40 °C
Weight~180 kg
Dimensions1800 × 610 × 700 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
OriginBeijing, China
ModelGXH-1051E
Instrument TypeOnline Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Target GasCarbon Monoxide (CO) only
Measurement Range0–50 ppm (standard), customizable up to 0–100% vol
Minimum Detectable Concentration0.1 ppm
Repeatability≤ ±1% FS
Linearity Error≤ ±2% FS
Zero Drift≤ ±1% FS / 24 h
Span Drift≤ ±1% FS / 24 h
Response Time (T90)≤ 60 s
Resolution0.1 ppm
Operating Humidity≤ 90% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50 Hz ±5%
Output Signals4–20 mA analog + RS232 digital interface
Internal Sampling PumpIntegrated
DisplayBacklit LCD with touch control
Data LoggingOnboard memory with USB/PC software download capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Physical & Chemical
ModelPQX-2002
Chamber Volume Options25 L, 50 L, 100 L (custom sizes available)
Dimensions (L×W×H)470×335×207 mm / 670×470×207 mm / 1020×520×224 mm
MaterialOptical-grade acrylic (PMMA)
Power SupplyAC 220 V, 50 Hz
Integrated FeaturesDigital温-humidity display, internal fan-assisted homogenization, pure gas inlet ports, exhaust valve, glove ports (built-in rubber gloves), analytical instrument interface ports
ComplianceDesigned to meet GB 15322–2019 requirements for alarm activation value testing of combustible and toxic gas detectors
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Physical & Chemical
OriginBeijing, China
ModelJF-2211
Volume Output Range1–1000 mL per injection
Concentration Dilution Ratioup to 1:400
Calibration Accuracy±1% of set volume
Compatible Gas TypesNon-corrosive gases only
Optional Mixing Chamber Volume10–100 L
Control SystemMicroprocessor-based programmable timing and sequencing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHXPQX-2020
Price RangeUSD 28,000–42,500
Internal Volume0.60 m³
Cross-Sectional Dimensions400 × 300 mm
Tunnel Length (Centerline)1850 mm
Temperature Range (High Temp Test)50–70 °C ±2 °C
Temperature Range (Low Temp Test)0–−40 °C ±2 °C
Humidity Range (Steady-State Damp Heat)93 %RH ±3 %RH at 40 °C ±2 °C
Air Velocity Range0–6.5 m/s ±0.2 m/s
Rotational Step45° per increment
Temp Measurement Accuracy±0.5 °C (Resolution ≤0.1 °C)
RH Measurement Accuracy±0.5 %RH (Resolution ≤0.1 %RH)
Air Velocity Measurement0.2–10 m/s, ±5 % error (Resolution ≤0.1 m/s)
Heating Rate≤1 °C/min
Cooling Rate0.5–1 °C/min
Humidification Rate≤5 %RH/min
Dehumidification Rate≤1 °C/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
ModelGXH-1052L
OriginBeijing, China
Instrument TypeOnline Gas Analyzer
Measured GasCO₂ (single-component)
Range0–500 ppm (standard), customizable up to 0–100% vol
Resolution1 ppm
Repeatability≤ ±1% FS
Linearity Error≤ ±2% FS
Zero Drift≤ ±2% FS / 8 h
Span Drift≤ ±2% FS / 8 h
Response Time (T₉₀)≤ 60 s
Warm-up Time≤ 60 min
Operating Humidity≤ 90% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50 Hz ±5%
Output Signal4–20 mA analog
Internal Sampling PumpIntegrated
Enclosure TypeRack-mountable embedded chassis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
OriginBeijing, China
ModelGXH-3051L
Instrument TypePortable
Detection TargetSingle-component CO
Measurement Range0–50 ppm
Repeatability±1% F.S.
Resolution0.1 ppm
Response Time≤15 s
Zero Drift≤±1% F.S./24 h
Span Drift≤±1% F.S./24 h
Linearity Error≤±2% F.S.
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelGXH-1050D
Price RangeUSD 1,400 – 7,000
Instrument TypeContinuous Emission Monitoring System (CEMS)
Measurement PrincipleNon-Dispersive Infrared (NDIR)
Accuracy≤ ±1% F.S.
Repeatability≤ ±1% F.S.
Response Time (T₀–T₉₀)≤ 15 s
Zero Drift≤ ±1% F.S. / 24 h
Span Drift≤ ±1% F.S. / 24 h
Linearity Error≤ ±1% F.S.
Detection GasesCO, CO₂, CH₄, C₃H₈, H₂, O₂
Minimum Range0–100 ppm
Maximum Range0–100% v/v
Flow Rate0.5–3 L/min
Operating Temperature0–40 °C
Relative Humidity≤ 90% RH (non-condensing)
Power Supply220 V ±10%, 50 Hz ±0.5 Hz, 150 W
Output Signals0–20 mA, 4–20 mA, 0–10 mV, 1–5 V (load ≤ 600 Ω, isolated)
DisplayDigital concentration readout with dual-range capability (ppm and % v/v)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
OriginBeijing, China
ModelGXH-3051E
Instrument TypePortable
Detection TargetSingle-component CO
Measurement Range0–50 ppm
Repeatability≤1% F.S.
Resolution0.1 ppm
Response Time≤30 s
Zero Drift≤±1% F.S.
Span Drift≤±1% F.S.
Linearity Error≤±1% F.S.
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelGXH-3051
PriceUpon Request
Measurement Range (CO₂)0–1000 ppm / 0–100% vol
Zero Drift≤ ±1% FS / 4 h
Span Drift≤ ±1% FS / 4 h
Linearity≤ ±1% FS
Repeatability≤ ±1%
Warm-up Time15 min
Weight1.5 kg
DisplayBacklit LCD with Direct Concentration Readout
Gas Flow ControlAdjustable via Integrated Flow Regulator
Calibration ModeSix-Port Manual Valve for Zero/Measurement Path Switching
PowerDual Rechargeable Battery System with Low-Voltage Alert
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Analytical
ModelJF-2215
OriginBeijing, China
Gas CompatibilityCH₄, CO, C₃H₈, H₂ (expandable to C₄H₁₀, C₂H₅OH)
Concentration Accuracy±2% FS
Repeatability1%
Stability (5 min)≤4% drift under sealed conditions
Predefined Concentration Steps7 per gas (user-configurable)
Gas TypeNon-corrosive gases only
Price RangeUSD 2,800 – 7,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunsquare
ModelGXH-3052L
Instrument TypePortable Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR)
Target GasCO₂ (single-component)
Measurement Range0–1000 ppm
Resolution1 ppm
Repeatability±1% FS
Linearity Error≤±2% FS
Zero Drift≤±2% FS
Span Drift≤±2% FS
Response Time (T₉₀)≤30 s
Power SupplyDC (battery-operated)
ComplianceDesigned per GB/T 18204.2–2014, HJ 870–2017, and ISO 8573-1 for ambient and stack gas CO₂ monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSUSS
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Instrument TypeContinuous Emission Monitoring System (CEMS)
ModelJF-2200
Gas Measurement RangesCO 0–1000 ppm
Measured ParametersO₂, CO, CO₂, CH₄, C₃H₈, C₄H₁₀, Total Hydrocarbons (HC), NOₓ, NO₂, N₂O, NH₃, SO₂, H₂S, temperature, humidity, static/total pressure, flue gas velocity
ComplianceDesigned to meet ISO 14064-1, EN 15267, and EPA Method 3A / 6C / 7E / 10 standards for stack emission verification