Empowering Scientific Discovery

Beijing Orient Defi Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA MOB-M
Instrument TypePortable Video-Based Optical Contact Angle Analyzer
Contact Angle Range0–180°
Contact Angle Accuracy±0.1° (0–90°), ±0.5° (90–180° for axisymmetric droplets)
Contact Angle Resolution0.1°
Surface Tension Range0.01–2000 mN/m
Surface Tension Accuracy±0.01 mN/m
Sample Stage Dimensions100 × 100 mm (fixed base unit)
Maximum Sample SizeUnlimited
Sample Stage Load CapacityUnlimited
Imaging SystemHigh-resolution, low-distortion industrial fixed-focus lens
Max Resolution752 × 480 px
Frame RateUp to 60 fps
Field of View12 × 8 mm
Light SourceMonochromatic, uniform LED cold light source with software-controlled intensity
Dispensing UnitIntegrated manual digital micro-dosage system
Dispensing Precision0.004 µL
Accuracy±0.01 µL
Device Dimensions77 × 60 × 150 mm (L×W×H)
Weight~1 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA200-T
Instrument TypeBenchtop Video Optical Contact Angle Analyzer
Contact Angle Measurement Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Surface/Interfacial Tension Range0.01–2000 mN/m
Surface/Interfacial Tension Resolution0.01 mN/m
Sample Stage Dimensions100 × 100 mm
Maximum Sample Dimensions (L × W × H)∞ × 310 × 76 mm
Stage Load Capacity12 kg
Optical Magnification6.5×
CameraUSB 3.0, 1920 × 1200 px, up to 3300 fps
Temperature Control OptionsCirculating Fluid or Peltier
Tilt StageMotorized 360° Continuous Rotation
Injection SystemNon-contact Electric Dispensing Unit (up to 3 independent syringe modules)
Software ComplianceSupports ASTM D724, ISO 19403-2/-3, ISO 15989, USP <1059>, GLP/GMP audit trails (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA 100
Instrument TypeBenchtop Video Optical Contact Angle Analyzer
Contact Angle Measurement Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Surface/Interfacial Tension Range0.01–2000 mN/m
Surface/Interfacial Tension Resolution0.01 mN/m
Sample Stage Dimensions100 × 100 mm
Maximum Sample Dimensions (L×W×H)∞ × 290 × 76 mm
Stage Load Capacity12 kg
Optical Zoom6.5× Motorized Telecentric Lens
Imaging SystemUSB 3.0 High-Speed Camera (752 × 480 px, up to 87 fps)
IlluminationAdjustable Uniform LED Cold Light Source
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeclis Scientific (France)
OriginFrance
ModelTRACKER
Measurement Range0–1000 mN/m
Resolution0.01 mN/m
Accuracy0.01 mN/m
Temperature Range0–200 °C
Temperature Accuracy±0.1 °C
MethodPendant Drop / Sessile Drop / Rising Bubble / Captive Bubble
CameraMonochrome CCD, 640×480 px, up to 60 fps (optional high-speed: 600 fps)
Optical SystemTelecentric lens + dual-intensity LED backlight
Sample CellJacketed thermostatted cell with integrated magnetic stirrer
Temperature ControlCirculating bath (up to 90 °C), embedded Pt100 sensor (±0.2 °C)
SoftwareYoung–Laplace fitting, dynamic interfacial rheology (dilatational modulus E', E''), contact angle hysteresis (advancing/receding), CMC determination, batch analysis, audit-trail-ready data logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA60
Instrument TypeBenchtop Video Optical Contact Angle Analyzer
Contact Angle Measurement Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Surface/Interfacial Tension Range0.01–2000 mN/m
Surface/Interfacial Tension Resolution0.01 mN/m
Sample Stage Dimensions100 mm × 100 mm
Maximum Sample Size (L×W×H)∞ × 240 × 76 mm
Sample Stage Load Capacity12 kg
Optical Zoom Lens6.5× (±6 mm focus adjustment)
Imaging SystemUSB 3.0 high-speed camera, 1280 × 1024 px resolution, up to 435 fps
Light SourceMonochromatic, uniform LED cold light with software- and manual-intensity control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA60G
Instrument TypeBenchtop Video Optical Contact Angle Analyzer
Contact Angle Range0–180°
Accuracy±0.1°
Resolution0.01°
Sample Stage Dimensions100 × 100 mm
Max. Sample Load12 kg
Max. Sample Dimensions∞ × 240 × 76 mm (L × W × H)
Lens1.3× Zoom Optical Lens
Image Resolution752 × 480 pixels
Frame Rate60 fps @ 752 × 480
Field of View8.5 × 5.3 to 10.5 × 6.6 mm
Light SourceMonochromatic, Uniform LED Cold Light (Manual & Software-Adjustable Intensity)
Power Supply110/240 V, 50/60 Hz, 90 W
Base Dimensions600 × 160 × 517 mm (L × W × H)
Weight15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA100M2
Instrument TypeBenchtop Video Optical Contact Angle Analyzer
Contact Angle Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Surface/Interfacial Tension Range0.001–2000 mN/m
Surface/Interfacial Tension Resolution0.01 mN/m
Sample Stage Dimensions100 × 100 mm
Maximum Sample Size (L×W×H)∞ × 240 × 76 mm
Stage Load Capacity12 kg
Imaging Magnification45× Zoom Lens
High-Speed CameraUSB 3.0, 1920 × 1200 px, up to 3300 fps
Field of View (Macro/Micro)2.0 × 1.3 – 13.1 × 8.3 mm / 0.2 × 0.13 – 1.31 × 0.83 mm
Light SourceMonochromatic Uniform LED, Software-Controllable Intensity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeclis Scientific
OriginFrance
ModelTRACKER H
Measurement Range0.1–1000 mN/m
Resolution0.01 mN/m
Accuracy±0.01 mN/m
Temperature Range0–200 °C
Temperature Accuracy±0.5 °C
Measurement MethodPendant Drop Method
Max Pressure200 bar
Max Temperature200 °C
Compatible GasesSupercritical CO₂, N₂, Ar, air, CO₂
Contact Angle Range0–180°
Contact Angle Accuracy±0.1°
Dynamic Contact Angle Accuracy±0.1°
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA200S
Instrument TypeBenchtop Video Optical Contact Angle Meter
Contact Angle Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Surface/Interfacial Tension Range0.001–2000 mN/m
Surface/Interfacial Tension Accuracy±0.01 mN/m
Sample Stage Dimensions100 × 100 mm
Maximum Sample Size (L×W×H)∞ × 290 × 76 mm
Stage Load Capacity12 kg
Imaging System1.9× Zoom Lens
High-Speed CameraUSB 3.0, 1280 × 1024 px, 60 fps
Field of View6.5 × 5.2 to 12.4 × 9.9 mm
Light SourceAdjustable LED Cold Light
Power Supply110/240 V, 50/60 Hz, 90 W
Instrument Footprint620 × 200 × 536 mm (L×W×H)
Weight22 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA100POM
Instrument TypeBenchtop Laboratory Analyzer
Contact Angle Measurement Range0–180°
Washburn Contact Angle Range0–90°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Surface/Interfacial Tension Range0.01–2000 mN/m
Surface/Interfacial Tension Resolution0.01 mN/m
Sample Stage Dimensions100 × 100 mm
Maximum Sample Size (L×W×H)∞ × 290 × 76 mm
Stage Load Capacity12 kg
Optical Zoom6.5× Motorized Zoom Lens
Image Resolution1280 × 960 pixels
Frame Rate54 fps @ full resolution
Liquid Level Tracking Precision10 µm
Absorbed Volume Resolution0.1 µL
Video Analysis Frequency for Powder Uptake15 Hz
Standard Capillary TubeVertical, 40 mm length × 10 mm diameter
Light SourceAdjustable High-Uniformity LED Cold Light
Power Supply110/240 V, 50/60 Hz, 90 W
Base Dimensions & Weight600 × 160 × 543 mm (L×W×H), 19 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA60T
Instrument TypeBenchtop Video Optical Contact Angle Analyzer
Contact Angle Measurement Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Surface/Interfacial Tension Range0.01–2000 mN/m
Surface/Interfacial Tension Accuracy0.01 mN/m
Sample Stage Dimensions100 × 100 mm
Maximum Sample Load12 kg
Maximum Sample Dimensions (L × W × H)∞ × 240 × 76 mm
Tilting Stage Range0–100°
Tilting Speed0.05–7 °/s
Optical System1.3× Zoom Lens (standard), 752 × 480 px @ 60 fps, FOV: 8.5 × 5.3 to 10.5 × 6.6 mm
IlluminationAdjustable High-Uniformity LED Cold Light Source
Power Supply110/240 V, 50/60 Hz, 90 W
Base Dimensions & Weight600 × 160 × 517 mm, 15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA200B
Instrument TypeBenchtop Video Optical Contact Angle Analyzer
Contact Angle Measurement Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Surface/Interfacial Tension Range0.001–2000 mN/m
Surface/Interfacial Tension Resolution0.01 mN/m
Sample Stage Dimensions100 × 100 mm
Maximum Sample Load12 kg
Maximum Sample Dimensions (L × W × H)∞ × 310 × 76 mm
Image Magnification6.5× Zoom Lens
Automated Tilting Stage0–360°
Adhesion Force Measurement (Vertical0.1 μN resolution
Horizontalup to 40g centrifugal equivalent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA MOB-X
Instrument TypePortable Video-Based Optical Contact Angle Analyzer
Contact Angle Range0–180°
Contact Angle Accuracy±0.1° (0–90°), ±0.5° (90–180° for axisymmetric droplets)
Contact Angle Resolution0.1°
Surface Tension Range0.01–2000 mN/m
Surface Tension Accuracy±0.01 mN/m
Sample Stage Dimensions100 × 100 mm (fixed base)
Imaging SystemHigh-resolution, low-distortion industrial fixed-focus optical lens with high-speed capture capability
Maximum Sample SizeUnlimited
Sample Stage Load CapacityUnlimited
Measurement GeometryTop-view (orthogonal overhead imaging)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA MOB-C
Instrument TypeBenchtop Video-Based Optical Contact Angle Analyzer
Contact Angle Measurement Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.1°
Surface/Interfacial Tension Measurement Range0.01–2000 mN/m
Surface/Interfacial Tension Accuracy±0.01 mN/m
Sample Stage Dimensions100 × 100 mm (fixed)
Maximum Sample Size∞ × 290 × 76 mm
Stage Load Capacity12 kg
Imaging SystemHigh-resolution, low-distortion, high-speed industrial fixed-focus optical lens
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA60 pro
Instrument TypeBenchtop Video Optical Contact Angle Analyzer
Contact Angle Measurement Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Surface/Interfacial Tension Range0.01–2000 mN/m
Surface/Interfacial Tension Resolution0.01 mN/m
Sample Stage Dimensions100 × 100 mm
Maximum Sample Size (L×W×H)∞ × 240 × 76 mm
Stage Load Capacity12 kg
Optical Zoom Lens6.5× Continuous Zoom
Camera Resolution1450 × 1080 pixels
Max Frame Rate3400 fps
Field of View1.1 × 0.8 to 14.3 × 10.7 mm
LED IlluminationHigh-Uniformity Cold Light Source, Software- and Manual-Adjustable Brightness
Power Supply110/240 V, 50/60 Hz, 90 W
Dimensions (Base Unit)650 × 160 × 517 mm (L×W×H)
Weight15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeclis Scientific
OriginFrance
ModelTRACKER HTHP 700
Measurement Range0.01–1000 mN/m
Resolution±0.01 mN/m
Accuracy0.01 mN/m
Temperature Range0–200 °C
Temperature Accuracy±0.1 °C
Measurement MethodPendant Drop or Rising Drop Shape Analysis
Maximum Pressure700 bar
Optical Cell MaterialSapphire Windows with Inconel 625 Housing
Imaging SystemUSB2 CCD Camera (640×480, 60 fps), Telecentric Lens (f = 55 mm), Zoom Ratio 0.5–0.05, Working Distance 98–191 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA200
Instrument TypeBenchtop Video Optical Contact Angle Analyzer
Contact Angle Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Surface/Interfacial Tension Range0.01–2000 mN/m
Surface/Interfacial Tension Resolution0.01 mN/m
Sample Stage Dimensions100 × 100 mm
Maximum Sample Size (L×W×H)∞ × 290 × 76 mm
Stage Load Capacity12 kg
Optical Zoom8.6× Motorized Telecentric Lens
Camera Resolution1920 × 1200 px
High-Speed Imagingup to 3300 fps
Field of View2.1 × 1.3 to 17.5 × 11 mm
SoftwareSurfaceMeter v6.x with ASTM/ISO-compliant algorithms
ComplianceISO 19403-3, ISO 19403-4, DIN 55660-3
Power Supply110/240 V, 50/60 Hz, 90 W
Dimensions (L×W×H)620 × 200 × 536 mm
Weight22 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeclis Scientific
OriginFrance
ModelFOAMSCAN HTMP
Max Operating Temperature120 °C
Max Operating Pressure8 bar
Gas Flow Range100–5000 mL/min
ImagingUSB 2.0 CCD camera (744 × 480 px, 76 fps), dual focal lengths (2.9 mm / 8.2 mm)
Sample Celltriple-walled cylindrical glass tube with integrated Pt100 temperature sensor and conductivity electrodes
Cleaningautomated rinse system
Compliancecompatible with GLP/GMP workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA MOB-P
Instrument TypeVideo-based Optical Contact Angle Analyzer (Top-View Configuration)
Contact Angle Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.1°
Surface Tension Range0.01–2000 mN/m
Surface Tension Accuracy±0.01 mN/m
Imaging SystemHigh-resolution, low-distortion industrial fixed-focus lens
Working DistanceUp to 25 mm
Sample Stage Dimensions100 × 100 mm (fixed base)
Measurement Cycle Time~1–2 seconds per droplet
Interface OptionsTTL digital output, software API (TCP/IP or DLL-based)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA100SML
Instrument TypeBenchtop Video Optical Contact Angle Analyzer
Contact Angle Measurement Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Surface/Interfacial Tension Range0.01–2000 mN/m
Surface/Interfacial Tension Resolution0.01 mN/m
Capillary Meniscus Height Resolution10 µm
Volume Measurement Resolution0.1 µL
Imaging Magnification6.5× Zoom Optical Lens
Maximum Sample Dimensions∞ × 290 × 76 mm (L×W×H)
Sample Stage Size100 × 100 mm
Sample Stage Load Capacity12 kg
Capillary PositioningMotorized X/Y/Z Precision Translation Stages
Image Capture RateUp to 150 fps @ 1920×1200 px
LightingAdjustable High-Uniformity LED Cold Light Source
SoftwareSurfaceMeter Professional Suite with ASTM/ISO-Compliant Data Logging & Audit Trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA100 B
Instrument TypeBenchtop Video Optical Contact Angle Analyzer
Contact Angle Measurement Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Surface/Interfacial Tension Range0.001–2000 mN/m
Surface/Interfacial Tension Resolution0.01 mN/m
Sample Stage Dimensions100 mm × 100 mm (fixed)
Maximum Sample Size∞ × 290 × 76 mm (L × W × H)
Stage Load Capacity12 kg
Optical Zoom6.5× Motorized Zoom Lens
Light SourceMonochromatic, Uniform LED Cold Light (Software & Manual Intensity Control)
Power Supply110/240 V, 50/60 Hz, 90 W
Instrument Dimensions600 × 160 × 543 mm (L × W × H)
Weight19 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA100B
Instrument TypeBenchtop Video Optical Contact Angle Analyzer
Contact Angle Measurement Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Surface/Interfacial Tension Range0.01–2000 mN/m
Surface/Interfacial Tension Resolution0.01 mN/m
Sample Stage Dimensions100 × 100 mm
Maximum Sample Size (L×W×H)∞ × 290 × 76 mm
Stage Load Capacity12 kg
Imaging System50 mm High-Resolution Low-Distortion Lens with USB3.0 High-Speed Camera (752 × 480 px, 87 fps)
Light SourceAdjustable High-Uniformity LED Cold Light
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
Manufacturer AuthorizationAuthorized Distributor
Import StatusImported
ModelLSA100RF
Instrument TypeVideo-Based Optical Contact Angle & Retention Force Analyzer
Form FactorBenchtop Laboratory System
Contact Angle Range0–180°
Contact Angle Accuracy±0.1°
Contact Angle Resolution0.01°
Surface Tension Range0.01–2000 mN/m
Surface Tension Accuracy±0.01 mN/m
Sample Stage Dimensions100 × 100 mm (fixed)
Max Sample Dimensions∞ × 290 × 76 mm
Stage Load Capacity12 kg
Optical Zoom6.5× Continuous Zoom Lens
Centrifuge ControlProgrammable Automatic Rotation Stage
Max Centrifugal Acceleration40 g
Rotational Speed Range0–750 rpm
Speed Control Precision±2 rpm
Angular Acceleration Range1–100 rpm/s
Force Resolution0.01 µN
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAUDA Scientific
OriginGermany
ModelLSA 200
Measurement Range0.001–2000 mN/m
Resolution0.01 mN/m
Accuracy±0.1 mN/m
Temperature Control Range−20 °C to 400 °C
Temperature Accuracy±0.1 °C
Measurement MethodVideo-based Drop Shape Analysis (DSA)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0