- All
- Favorite
- Popular
- Most rated
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA MOB-M |
| Instrument Type | Portable Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° (0–90°), ±0.5° (90–180° for axisymmetric droplets) |
| Contact Angle Resolution | 0.1° |
| Surface Tension Range | 0.01–2000 mN/m |
| Surface Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm (fixed base unit) |
| Maximum Sample Size | Unlimited |
| Sample Stage Load Capacity | Unlimited |
| Imaging System | High-resolution, low-distortion industrial fixed-focus lens |
| Max Resolution | 752 × 480 px |
| Frame Rate | Up to 60 fps |
| Field of View | 12 × 8 mm |
| Light Source | Monochromatic, uniform LED cold light source with software-controlled intensity |
| Dispensing Unit | Integrated manual digital micro-dosage system |
| Dispensing Precision | 0.004 µL |
| Accuracy | ±0.01 µL |
| Device Dimensions | 77 × 60 × 150 mm (L×W×H) |
| Weight | ~1 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA200-T |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Dimensions (L × W × H) | ∞ × 310 × 76 mm |
| Stage Load Capacity | 12 kg |
| Optical Magnification | 6.5× |
| Camera | USB 3.0, 1920 × 1200 px, up to 3300 fps |
| Temperature Control Options | Circulating Fluid or Peltier |
| Tilt Stage | Motorized 360° Continuous Rotation |
| Injection System | Non-contact Electric Dispensing Unit (up to 3 independent syringe modules) |
| Software Compliance | Supports ASTM D724, ISO 19403-2/-3, ISO 15989, USP <1059>, GLP/GMP audit trails (optional) |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA 100 |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Dimensions (L×W×H) | ∞ × 290 × 76 mm |
| Stage Load Capacity | 12 kg |
| Optical Zoom | 6.5× Motorized Telecentric Lens |
| Imaging System | USB 3.0 High-Speed Camera (752 × 480 px, up to 87 fps) |
| Illumination | Adjustable Uniform LED Cold Light Source |
| Brand | Teclis Scientific (France) |
|---|---|
| Origin | France |
| Model | TRACKER |
| Measurement Range | 0–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | 0.01 mN/m |
| Temperature Range | 0–200 °C |
| Temperature Accuracy | ±0.1 °C |
| Method | Pendant Drop / Sessile Drop / Rising Bubble / Captive Bubble |
| Camera | Monochrome CCD, 640×480 px, up to 60 fps (optional high-speed: 600 fps) |
| Optical System | Telecentric lens + dual-intensity LED backlight |
| Sample Cell | Jacketed thermostatted cell with integrated magnetic stirrer |
| Temperature Control | Circulating bath (up to 90 °C), embedded Pt100 sensor (±0.2 °C) |
| Software | Young–Laplace fitting, dynamic interfacial rheology (dilatational modulus E', E''), contact angle hysteresis (advancing/receding), CMC determination, batch analysis, audit-trail-ready data logging |
| Brand | SDI |
|---|---|
| Origin | Japan |
| Model | ND-0407-N1-CE |
| Z-Axis Travel | 100 mm |
| X-Axis Travel | 100 mm |
| Minimum Withdrawal Speed | 1 nm/s |
| Maximum Withdrawal Speed | 60 mm/s |
| Speed Control Resolution | 1 nm/s |
| Programmable Speed Change Points | 16 |
| Programmable Stop Positions | 16 |
| Programmable Dwell Times | 16 |
| Stored Motion Programs | 8 |
| Max Load Capacity | 500 g |
| Max Substrate Height | 100 mm |
| Power Supply | AC 100 V, 300 VA |
| Dimensions (Unit) | 442 × 250 × 451 mm |
| Dimensions (Control Box) | 300 × 285 × 163 mm |
| Standard Clamp Material | Polypropylene (PP) |
| Operating Languages | English & Japanese (toggleable) |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA60 |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 mm × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 240 × 76 mm |
| Sample Stage Load Capacity | 12 kg |
| Optical Zoom Lens | 6.5× (±6 mm focus adjustment) |
| Imaging System | USB 3.0 high-speed camera, 1280 × 1024 px resolution, up to 435 fps |
| Light Source | Monochromatic, uniform LED cold light with software- and manual-intensity control |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA60G |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Accuracy | ±0.1° |
| Resolution | 0.01° |
| Sample Stage Dimensions | 100 × 100 mm |
| Max. Sample Load | 12 kg |
| Max. Sample Dimensions | ∞ × 240 × 76 mm (L × W × H) |
| Lens | 1.3× Zoom Optical Lens |
| Image Resolution | 752 × 480 pixels |
| Frame Rate | 60 fps @ 752 × 480 |
| Field of View | 8.5 × 5.3 to 10.5 × 6.6 mm |
| Light Source | Monochromatic, Uniform LED Cold Light (Manual & Software-Adjustable Intensity) |
| Power Supply | 110/240 V, 50/60 Hz, 90 W |
| Base Dimensions | 600 × 160 × 517 mm (L × W × H) |
| Weight | 15 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA100M2 |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.001–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 240 × 76 mm |
| Stage Load Capacity | 12 kg |
| Imaging Magnification | 45× Zoom Lens |
| High-Speed Camera | USB 3.0, 1920 × 1200 px, up to 3300 fps |
| Field of View (Macro/Micro) | 2.0 × 1.3 – 13.1 × 8.3 mm / 0.2 × 0.13 – 1.31 × 0.83 mm |
| Light Source | Monochromatic Uniform LED, Software-Controllable Intensity |
| Brand | Teclis Scientific |
|---|---|
| Origin | France |
| Model | TRACKER H |
| Measurement Range | 0.1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Range | 0–200 °C |
| Temperature Accuracy | ±0.5 °C |
| Measurement Method | Pendant Drop Method |
| Max Pressure | 200 bar |
| Max Temperature | 200 °C |
| Compatible Gases | Supercritical CO₂, N₂, Ar, air, CO₂ |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Dynamic Contact Angle Accuracy | ±0.1° |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA200S |
| Instrument Type | Benchtop Video Optical Contact Angle Meter |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.001–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 290 × 76 mm |
| Stage Load Capacity | 12 kg |
| Imaging System | 1.9× Zoom Lens |
| High-Speed Camera | USB 3.0, 1280 × 1024 px, 60 fps |
| Field of View | 6.5 × 5.2 to 12.4 × 9.9 mm |
| Light Source | Adjustable LED Cold Light |
| Power Supply | 110/240 V, 50/60 Hz, 90 W |
| Instrument Footprint | 620 × 200 × 536 mm (L×W×H) |
| Weight | 22 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA100POM |
| Instrument Type | Benchtop Laboratory Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Washburn Contact Angle Range | 0–90° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 290 × 76 mm |
| Stage Load Capacity | 12 kg |
| Optical Zoom | 6.5× Motorized Zoom Lens |
| Image Resolution | 1280 × 960 pixels |
| Frame Rate | 54 fps @ full resolution |
| Liquid Level Tracking Precision | 10 µm |
| Absorbed Volume Resolution | 0.1 µL |
| Video Analysis Frequency for Powder Uptake | 15 Hz |
| Standard Capillary Tube | Vertical, 40 mm length × 10 mm diameter |
| Light Source | Adjustable High-Uniformity LED Cold Light |
| Power Supply | 110/240 V, 50/60 Hz, 90 W |
| Base Dimensions & Weight | 600 × 160 × 543 mm (L×W×H), 19 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA60T |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Load | 12 kg |
| Maximum Sample Dimensions (L × W × H) | ∞ × 240 × 76 mm |
| Tilting Stage Range | 0–100° |
| Tilting Speed | 0.05–7 °/s |
| Optical System | 1.3× Zoom Lens (standard), 752 × 480 px @ 60 fps, FOV: 8.5 × 5.3 to 10.5 × 6.6 mm |
| Illumination | Adjustable High-Uniformity LED Cold Light Source |
| Power Supply | 110/240 V, 50/60 Hz, 90 W |
| Base Dimensions & Weight | 600 × 160 × 517 mm, 15 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA200B |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.001–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Load | 12 kg |
| Maximum Sample Dimensions (L × W × H) | ∞ × 310 × 76 mm |
| Image Magnification | 6.5× Zoom Lens |
| Automated Tilting Stage | 0–360° |
| Adhesion Force Measurement (Vertical | 0.1 μN resolution |
| Horizontal | up to 40g centrifugal equivalent) |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA MOB-X |
| Instrument Type | Portable Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° (0–90°), ±0.5° (90–180° for axisymmetric droplets) |
| Contact Angle Resolution | 0.1° |
| Surface Tension Range | 0.01–2000 mN/m |
| Surface Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm (fixed base) |
| Imaging System | High-resolution, low-distortion industrial fixed-focus optical lens with high-speed capture capability |
| Maximum Sample Size | Unlimited |
| Sample Stage Load Capacity | Unlimited |
| Measurement Geometry | Top-view (orthogonal overhead imaging) |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA MOB-C |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.1° |
| Surface/Interfacial Tension Measurement Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm (fixed) |
| Maximum Sample Size | ∞ × 290 × 76 mm |
| Stage Load Capacity | 12 kg |
| Imaging System | High-resolution, low-distortion, high-speed industrial fixed-focus optical lens |
| Brand | Eastern-Dataphy |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrumentation |
| Model | VMF100 |
| Pricing | Upon Request |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA60 pro |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 240 × 76 mm |
| Stage Load Capacity | 12 kg |
| Optical Zoom Lens | 6.5× Continuous Zoom |
| Camera Resolution | 1450 × 1080 pixels |
| Max Frame Rate | 3400 fps |
| Field of View | 1.1 × 0.8 to 14.3 × 10.7 mm |
| LED Illumination | High-Uniformity Cold Light Source, Software- and Manual-Adjustable Brightness |
| Power Supply | 110/240 V, 50/60 Hz, 90 W |
| Dimensions (Base Unit) | 650 × 160 × 517 mm (L×W×H) |
| Weight | 15 kg |
| Brand | Teclis Scientific |
|---|---|
| Origin | France |
| Model | TRACKER HTHP 700 |
| Measurement Range | 0.01–1000 mN/m |
| Resolution | ±0.01 mN/m |
| Accuracy | 0.01 mN/m |
| Temperature Range | 0–200 °C |
| Temperature Accuracy | ±0.1 °C |
| Measurement Method | Pendant Drop or Rising Drop Shape Analysis |
| Maximum Pressure | 700 bar |
| Optical Cell Material | Sapphire Windows with Inconel 625 Housing |
| Imaging System | USB2 CCD Camera (640×480, 60 fps), Telecentric Lens (f = 55 mm), Zoom Ratio 0.5–0.05, Working Distance 98–191 mm |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA200 |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 290 × 76 mm |
| Stage Load Capacity | 12 kg |
| Optical Zoom | 8.6× Motorized Telecentric Lens |
| Camera Resolution | 1920 × 1200 px |
| High-Speed Imaging | up to 3300 fps |
| Field of View | 2.1 × 1.3 to 17.5 × 11 mm |
| Software | SurfaceMeter v6.x with ASTM/ISO-compliant algorithms |
| Compliance | ISO 19403-3, ISO 19403-4, DIN 55660-3 |
| Power Supply | 110/240 V, 50/60 Hz, 90 W |
| Dimensions (L×W×H) | 620 × 200 × 536 mm |
| Weight | 22 kg |
| Brand | Teclis Scientific |
|---|---|
| Origin | France |
| Model | FOAMSCAN HTMP |
| Max Operating Temperature | 120 °C |
| Max Operating Pressure | 8 bar |
| Gas Flow Range | 100–5000 mL/min |
| Imaging | USB 2.0 CCD camera (744 × 480 px, 76 fps), dual focal lengths (2.9 mm / 8.2 mm) |
| Sample Cell | triple-walled cylindrical glass tube with integrated Pt100 temperature sensor and conductivity electrodes |
| Cleaning | automated rinse system |
| Compliance | compatible with GLP/GMP workflows |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA MOB-P |
| Instrument Type | Video-based Optical Contact Angle Analyzer (Top-View Configuration) |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.1° |
| Surface Tension Range | 0.01–2000 mN/m |
| Surface Tension Accuracy | ±0.01 mN/m |
| Imaging System | High-resolution, low-distortion industrial fixed-focus lens |
| Working Distance | Up to 25 mm |
| Sample Stage Dimensions | 100 × 100 mm (fixed base) |
| Measurement Cycle Time | ~1–2 seconds per droplet |
| Interface Options | TTL digital output, software API (TCP/IP or DLL-based) |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA100SML |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Capillary Meniscus Height Resolution | 10 µm |
| Volume Measurement Resolution | 0.1 µL |
| Imaging Magnification | 6.5× Zoom Optical Lens |
| Maximum Sample Dimensions | ∞ × 290 × 76 mm (L×W×H) |
| Sample Stage Size | 100 × 100 mm |
| Sample Stage Load Capacity | 12 kg |
| Capillary Positioning | Motorized X/Y/Z Precision Translation Stages |
| Image Capture Rate | Up to 150 fps @ 1920×1200 px |
| Lighting | Adjustable High-Uniformity LED Cold Light Source |
| Software | SurfaceMeter Professional Suite with ASTM/ISO-Compliant Data Logging & Audit Trail |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA100 B |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.001–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 mm × 100 mm (fixed) |
| Maximum Sample Size | ∞ × 290 × 76 mm (L × W × H) |
| Stage Load Capacity | 12 kg |
| Optical Zoom | 6.5× Motorized Zoom Lens |
| Light Source | Monochromatic, Uniform LED Cold Light (Software & Manual Intensity Control) |
| Power Supply | 110/240 V, 50/60 Hz, 90 W |
| Instrument Dimensions | 600 × 160 × 543 mm (L × W × H) |
| Weight | 19 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA100B |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 290 × 76 mm |
| Stage Load Capacity | 12 kg |
| Imaging System | 50 mm High-Resolution Low-Distortion Lens with USB3.0 High-Speed Camera (752 × 480 px, 87 fps) |
| Light Source | Adjustable High-Uniformity LED Cold Light |
Show next