BrandAvenir
OriginGermany
Detector TypeCCD
Spectral Range350–840 nm
Resolution (FWHM)0.65 nm (typ.), 0.80 nm (max.)
Signal-to-Noise Ratio350 (Toshiba TCD1304DG), 600 (Hamamatsu S11639-01)
Dynamic Range1900:1 (Toshiba), 5000:1 (Hamamatsu)
Stray Light< 0.08 %
Optical DesignSymmetric Czerny-Turner, f = 50 mm, NA = 0.16
Input SlitUser-replaceable 20 µm (standard)
InterfaceUSB 2.0 Full-Speed (Type-C), SMA fiber port
Dimensions67.0 × 74.0 × 19.0 mm
Weight122 g
Operating Temperature−20 to +60 °C
ComplianceEU EMC Directive 2014/30/EU, RoHS, REACH SVHC, U.S. Conflict Minerals Act
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAvenir
OriginGermany
Manufacturer TypeAuthorized Distributor
Product CategoryImported
ModelAris
Spectral Range185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm
Detector TypeCCD
Resolution (FWHM)0.33–1.40 nm
Signal-to-Noise Ratio350 or 600 (max, unaveraged)
Dynamic Range1900:1 or 5000:1
Stray Light< 0.08 %
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAvenir
OriginGermany
ModelSiena
Spectral Range900–1700 nm, 800–1900 nm, 900–2100 nm
Detector TypeInGaAs CCD Array
Optical Resolution (FWHM)8–15 nm (configurable)
Signal-to-Noise Ratio1000 (max, unaveraged)
Dynamic Range12,000:1
Stray Light< 0.08 %
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAvenir
OriginGermany
ModelSie na
Spectral Range900–1700 nm, 800–1900 nm, 900–2100 nm
Detector TypeInGaAs CCD Array
Optical Resolution (FWHM)8 nm (typ.), up to 15 nm (max.)
Signal-to-Noise Ratio1000 (unaveraged)
Dynamic Range12,000:1
Stray Light< 0.08 %
Entrance Slit20 µm (user-replaceable)
InterfaceUSB 2.0 Full-Speed, UART, optional SPI/I²C
Power Supply5 V DC (4.4–5.5 V), ≤ 60 mW
Dimensions52.0 × 57.0 × 17.0 mm
Weight80 g
Operating Temperature–20 °C to +60 °C
ComplianceEU EMC Directive 2014/30/EU, RoHS, REACH SVHC, U.S. Conflict Minerals Law
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAvenir
OriginGermany
Detector TypeInGaAs Linear Array (Non-Cooled)
Spectral Range900–1700 nm / 800–1900 nm / 900–2100 nm
Resolution (FWHM)8–15 nm (configurable)
Signal-to-Noise Ratio1000 (max, unaveraged)
Dynamic Range12,000:1
Stray Light< 0.08 %
Entrance SlitUser-Replaceable (default 20 µm)
Optical DesignSymmetric Czerny-Turner, f = 30 mm, NA = 0.19
InterfaceUSB 2.0 Full-Speed (Type-C), UART, optional SPI/I²C
Power5 V DC (4.4–5.5 V), ≤60 mW
Dimensions52.0 × 57.0 × 17.0 mm
Weight80 g
Operating Temperature−20 to +60 °C
ComplianceEU EMC Directive 2014/30/EU, RoHS, REACH SVHC, U.S. Conflict Minerals Act
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAvenir
OriginGermany
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelAris
Spectral Range185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm
Detector TypeCCD
Optical Resolution (FWHM)0.33–1.40 nm
Signal-to-Noise Ratio350 or 600 (max, unaveraged)
Dynamic Range1900:1 or 5000:1
Stray Light< 0.08 %
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAvenir
OriginGermany
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelARIS
Spectral Range185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm
Detector TypeCCD
Optical Resolution (FWHM)0.33–1.40 nm
Signal-to-Noise Ratio350 or 600 (max, unaveraged)
Dynamic Range1900:1 or 5000:1
Stray Light< 0.08 %
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAvenir
OriginGermany
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelNYLIS
Spectral Range185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm
Detector TypeCMOS (Hamamatsu S13496)
Optical Resolution (FWHM)0.05–1.40 nm (configurable)
Sensitivity0.05 nm resolution mode
Signal-to-Noise Ratio350 or 600 (typ.), up to 550 (spec.)
dynamic range1900:1 or 5000:1 (spec.)
Stray Light< 0.08 %
Focal Length120 mm
Slit Width (standard)10 µm
Pixel Count4096
A/D Converter16-bit, 2 MHz
InterfaceUSB 2.0 Full-Speed (Type-C), UART, optional SPI/I²C
Dimensions67.0 × 150.0 × 19.0 mm
Weight178 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAvenir
OriginGermany
ModelAris
Spectral Range185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm
Detector TypeCCD
Optical Resolution (FWHM)0.33–1.40 nm
Signal-to-Noise Ratio350:1 or 600:1
Dynamic Range1900:1 or 5000:1
Stray Light< 0.08 %
Optical DesignSymmetric Czerny-Turner with 50 mm focal length
Numerical Aperture0.16
Input SlitUser-replaceable 20 µm (standard)
InterfaceUSB 2.0 Full Speed (Type-C), optional UART/SPI/I²C
ADC16-bit, 2 MHz
Power5 V via USB or auxiliary connector (4.4–5.5 V), ≤ 70 mA
Dimensions67.0 × 74.0 × 19.0 mm
Weight122 g
Operating Temperature–20 to +60 °C
Storage Temperature–40 to +70 °C
ComplianceEU EMC Directive 2014/30/EU, RoHS, REACH SVHC, U.S. Conflict Minerals Act
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAvenir
OriginGermany
ModelSiena
Spectral Range900–1700 nm, 800–1900 nm, 900–2100 nm
Detector TypeInGaAs CCD Linear Array
Optical Resolution (FWHM)8–15 nm (configurable)
Signal-to-Noise Ratio1000 (max, unaveraged)
Dynamic Range12,000:1
Stray Light< 0.08 %
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAvenir
OriginGermany
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelAris
PriceUpon Request
Spectral Range185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm
DetectorCCD
Optical Resolution (FWHM)0.33–1.40 nm
Signal-to-Noise Ratio350:1 or 600:1
Dynamic Range1900:1 or 5000:1
Stray Light< 0.08 %
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAvenir
OriginGermany
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelSiena
Spectral Range900–1700 nm, 800–1900 nm, 900–2100 nm
Detector TypeCCD
Optical Resolution (FWHM)8 nm
Signal-to-Noise Ratio1000
Dynamic Range12,000:1
Stray Light< 0.08 %
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAvenir
OriginGermany
ModelNYLIS
Spectral Range185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm
Detector TypeCMOS (Hamamatsu S13496)
Resolution (FWHM)down to 0.05 nm
Spectral Sampling4096 pixels
Slit Width (standard)10 µm
Stray Light< 0.1%
Dynamic Range5500:1 (typ.), 1900:1 to 5000:1 (configurable)
Signal-to-Noise Ratio350–600 (typ. 550, unaveraged)
Optical DesignSymmetric Czerny-Turner
Focal Length120 mm
Numerical Aperture0.07
InterfaceUSB 2.0 Full-Speed (Type-C), UART, optional SPI/I²C
Power Supply4.4–5.5 V DC (via USB or Aux), ≤70 mA
Dimensions67.0 × 150.0 × 19.0 mm
Weight178 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAvenir
OriginGermany
TypeFiber Optic Spectrometer
ModelAris Miniature Spectrometer
Spectral Range185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm
DetectorCCD/CMOS
Resolution (FWHM)0.33–1.40 nm (typ.)
Signal-to-Noise Ratio350 or 600 (max., unaveraged)
Dynamic Range1900:1 or 5000:1 (single-pixel, unaveraged)
Stray Light< 0.08 %
Optical DesignSymmetrical Czerny-Turner
Focal Length50 mm
Numerical Aperture0.16
Input SlitUser-replaceable, default 20 µm
A/D Converter16-bit, 2 MHz
InterfaceUSB 2.0 Full-Speed, UART
Dimensions67.0 × 74.0 × 19.0 mm
Weight122 g
Operating Temperature−20 to +60 °C
Storage Temperature−40 to +70 °C
Humidity0–90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTaiKun
OriginUSA
ModelTK-2020-PM2.5
Filter MaterialElectrostatically Charged Polypropylene
Basis Weight40 g/m²
Thickness0.2 mm
Filtration Efficiency99.995% (NaCl, 0.3–0.5 µm, face velocity 0.1 m/s, test area 50 cm²)
Pressure Drop137 Pa (same test conditions)
Filter GeometryCustomizable shape and size per client specification
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLightnovo
OriginDenmark
TypeConfocal Micro-Raman Spectrometer
ModelMicro-Raman Microscope
Spectral Range786 cm⁻¹ (excitation wavelength, typically 785 nm laser)
Spectral Resolution2.5–3 cm⁻¹
Lateral Spatial Resolution800–900 nm
Axial (Z) Resolution2.5–3 µm
Dimensions175 × 180 × 410 mm
Weight9.5–11.5 kg
Microscope ConfigurationUpright & Inverted
XYZ Travel Range (Motorized)30 × 30 × 30 mm
XYZ Travel Range (Manual)10 × 10 × 13 mm
Minimum Step Size500 nm (XY), 500 nm (Z)
White-Light Reflectance ImagingIntegrated real-time camera with simultaneous laser spot visualization and Raman acquisition
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTaiKun
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelTK-2020
Typical ConfigurationIntegrated High-Flow Particulate Sampler
Flow Range0–20,000 L/min
Vacuum Pressure CapabilityUp to 2.0 kPa (not L/min — corrected per engineering standard)
Continuous Operation Duration at Rated High Flow & Resistance24 h
Service Life at Maximum Flow and System Backpressure168 h
Basis Weight40 g/m²
Thickness0.2 mm
Filtration Efficiency99.995% (NaCl aerosol, 0.3–0.5 µm, face velocity 0.1 m/s, test area 50 cm²)
Initial Pressure Drop137 Pa (same test conditions)
MaterialElectrostatically Charged Polypropylene
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTaiKun
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelTK-GEM50P4-83-RB-SMP
Instrument TypeLaboratory Gamma Spectrometer
Detector TypeP-type Coaxial High-Purity Germanium (HPGe)
Measurement ModeGamma-ray Spectrometry
Sample FormSolid
Energy Range30 keV – 10 MeV
Relative Efficiency≥50% @ 1.33 MeV
Energy Resolution (FWHM)≤0.85 keV @ 122 keV, ≤1.8 keV @ 1.33 MeV
Peak-to-Compton Ratio≥53
Peak Shape (FW.02M/FWHM)≤3.0
Cooling MethodElectromechanical Cryocooler (Pulse Tube) with 25 L LN₂ Dewar
ShieldingDual-layer low-background lead chamber (15 cm Pb + Cu/Sn lining)
Software ComplianceSupports FDA 21 CFR Part 11 audit trails, GLP/GMP data integrity protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGEORADIS
OriginCzech Republic
ModelRT-50 A
Instrument TypeLaboratory Gamma Spectrometer
Detector TypeNaI(Tl) Scintillation Crystal (76 mm × 76 mm, 0.35 L)
Measurement Range20 keV – 3.0 MeV
Energy Resolution≤7.5% FWHM at 662 keV (¹³⁷Cs)
Sensitivity0.02 Bq/g (for ⁶⁰Co)
Channel Count1024-channel MCA
Shielding≥9 cm lead equivalent (min. wall thickness 3.5 in), integrated sliding heavy-duty shielded lid
Dimensions (H×W×D)770 × 360 × 620 mm
Weight410 kg (lead-shielded configuration: 580 kg)
InterfaceUSB 2.0
Operating Temperature0–40 °C
Software PlatformLabCentre (Windows/Linux, FirebirdSQL 2.6+)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTaiKun
OriginGermany
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelLINCam
Instrument TypeSynchronized Scanning Streak Camera
Photocathode MaterialGaAsP (not "钴ui" — corrected per standard industry nomenclature)
Photocathode Active Area0.2 mm²
Spectral Response Range300–900 nm
Timing Resolution40 ps FWHM
Spatial Resolution1000 × 1000 pixels
Detection ModeTime-Correlated Single-Photon Counting (TCSPC)
InterfacePCIe 3.0 x8
Trigger InputSMA, LVDS-compatible
Software SupportWindows/Linux SDK, MATLAB & Python APIs
ComplianceCE, RoHS, ISO 9001-certified manufacturing environment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTaiKun
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTK-Mobius
Instrument CategoryGamma-Ray Spectrometer
Instrument TypeLaboratory-Based
Sample FormSolid
Detector TypeHigh-Purity Germanium (HPGe)
Cooling MethodLiquid Nitrogen Recondensation (Closed-Cycle)
Operating Temperature≤ 77 K
Nominal Dewar Capacity28 L
Continuous Operation (Uninterrupted Power)Up to 2 Years
Power Consumption125 W (Typical), 300 W (Max)
Ambient Operating Conditions0–40 °C, 20–90% RH (Non-Condensing)
Acoustic Noise Level< 60 dB(A) at 1 m
Displayed ParametersCryocooler Status, Estimated Remaining Cryogenic Hold Time (h), LN₂ Level, Low-Level Warning Threshold (48 h)
Physical Dimensions (Dewar Only)66.5 cm H × 44.1 cm Ø
Air Filter Maintenance IntervalMonthly
Mounting FlexibilityVertical or Horizontal Cold Finger Orientation
Electronics ArchitectureDecoupled Cryo-Control and Signal Processing Circuitry (Separated from Dewar)