BrandTouchScience
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Sample Tray Capacity20 positions
Vial Size20 mL
Oven Temperature RangeAmbient to 200 °C (1 °C increments)
Valve & Transfer Line Temperature RangeAmbient to 220 °C
Temperature Control Accuracy±0.1 °C
Inert Flow PathSilcoNert®-treated stainless steel needle and heated transfer lines (no cold spots)
Interface CompatibilityUniversal GC & GC-MS systems (Agilent, Thermo Fisher, Shimadzu, PerkinElmer, etc.)
Audit TrailBuilt-in method logging with timestamped parameter history
Display7-inch capacitive touchscreen HMI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTouchScience
OriginBeijing, China
ManufacturerYes
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Sample Tray Capacity45 positions
Vial Size20 mL (10 mL optional)
Oven Temperature RangeAmbient to 220 °C
Valve & Transfer Line Temperature RangeAmbient to 220 °C
Temperature Control Accuracy±0.1 °C
Loop Volume1 mL
Heating Zones6 independent heated positions with optional agitation
Leak DetectionAutomated vial and tubing integrity check
Log FunctionMethod and parameter audit trail
Dimensions (H×W×D)680 × 380 × 500 mm
Timing Accuracy<0.1%
Pneumatic Pressure Rating>0.4 MPa
Synchronization OutputsTwo TTL-compatible dry-contact signals (1–2 s duration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTouchScience
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Vial Heating RangeAmbient to 220 °C
Valve Temperature Control RangeAmbient to 220 °C
Temperature Control Accuracy±0.1 °C
Sample Loop Volume1 mL
Sample Capacity100 positions
Vial Sizes Supported10 mL and 20 mL (20 mL standard, 10 mL optional)
Timing Range0.01–500 minutes
Timing Accuracy<0.1%
Pneumatic Pressure Rating>0.4 MPa
Synchronization OutputsTwo TTL-compatible switch signals (1–2 s duration)
Dimensions (H×W×D)460 mm × 605 mm × 860 mm
Display7-inch capacitive touchscreen interface
Motion SystemXYZ three-axis robotic positioning platform
Pressure ControlElectronic Pressure Control (EPC)
Leak DetectionAutomated vial and line integrity verification
Sample Transfer PathHeated, inert-surface tubing and needle (no cold spots)
AgitationHeated-position orbital shaking
Data TraceabilityBuilt-in audit-trail-capable method and event logging