| Brand | TouchScience |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 20 positions |
| Vial Size | 20 mL |
| Oven Temperature Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Inert Flow Path | SilcoNert®-treated stainless steel needle and heated transfer lines (no cold spots) |
| Interface Compatibility | Universal GC & GC-MS systems (Agilent, Thermo Fisher, Shimadzu, PerkinElmer, etc.) |
| Audit Trail | Built-in method logging with timestamped parameter history |
| Display | 7-inch capacitive touchscreen HMI |
| Brand | TouchScience |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 45 positions |
| Vial Size | 20 mL (10 mL optional) |
| Oven Temperature Range | Ambient to 220 °C |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Loop Volume | 1 mL |
| Heating Zones | 6 independent heated positions with optional agitation |
| Leak Detection | Automated vial and tubing integrity check |
| Log Function | Method and parameter audit trail |
| Dimensions (H×W×D) | 680 × 380 × 500 mm |
| Timing Accuracy | <0.1% |
| Pneumatic Pressure Rating | >0.4 MPa |
| Synchronization Outputs | Two TTL-compatible dry-contact signals (1–2 s duration) |
| Brand | TouchScience |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 220 °C |
| Valve Temperature Control Range | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 100 positions |
| Vial Sizes Supported | 10 mL and 20 mL (20 mL standard, 10 mL optional) |
| Timing Range | 0.01–500 minutes |
| Timing Accuracy | <0.1% |
| Pneumatic Pressure Rating | >0.4 MPa |
| Synchronization Outputs | Two TTL-compatible switch signals (1–2 s duration) |
| Dimensions (H×W×D) | 460 mm × 605 mm × 860 mm |
| Display | 7-inch capacitive touchscreen interface |
| Motion System | XYZ three-axis robotic positioning platform |
| Pressure Control | Electronic Pressure Control (EPC) |
| Leak Detection | Automated vial and line integrity verification |
| Sample Transfer Path | Heated, inert-surface tubing and needle (no cold spots) |
| Agitation | Heated-position orbital shaking |
| Data Traceability | Built-in audit-trail-capable method and event logging |