- All
- Favorite
- Popular
- Most rated
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1152 |
| Portability | Portable |
| Application Environment | Laboratory & Field |
| Conductivity Range | 0–1999 pS/m |
| Temperature Range | 0 °C to 75 °C |
| Accuracy | ±2% of reading or ±1 pS/m (whichever is greater) |
| Resolution | 1 pS/m |
| Display | LCD |
| Calibration | Auto-calibration via field-adjustable circuitry |
| Power Supply | 3 × AA alkaline batteries |
| Enclosure | Anodized aluminum housing with corrosion-resistant coating |
| Probe | Removable stainless-steel electrode |
| Safety Certification | UL, CSA, LCIE certified for Class I, Division 1 hazardous locations |
| Compliance | ASTM D2624–22 (Standard Test Method for Electrical Conductivity of Aviation Turbine Fuels) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | TG268 |
| Type | Automatic Gloss Meter |
| Measurement Angles | 20°, 60°, 85° |
| Measurement Areas (mm) | 20°: 10×10, 60°: 9×15, 85°: 5×36 |
| Measurement Ranges | 20°: 0–2000 GU, 60°: 0–1000 GU, 85°: 0–160 GU |
| Resolution | 0.1 GU |
| Repeatability | ±0.1 GU (0–10 GU), ±0.2 GU (10–100 GU), ±0.2% GU (100–2000 GU) |
| Reproducibility | ±0.2 GU (0–10 GU), ±0.5 GU (10–100 GU), ±0.5% GU (100–2000 GU) |
| Geometry | CIE 1931 Standard Observer (2°), Illuminant C |
| Compliance | ISO 2813, ASTM D523, ASTM D2457, GB/T 9754 |
| Response Time | 1.0 s |
| Display | 3.5″ TFT capacitive touchscreen |
| Data Storage | 1,000 readings (Basic), 5,000 (Statistical & Continuous modes) |
| Interface | USB, RS-232 |
| Power | Rechargeable 3200 mAh Li-ion battery (up to 10,000 measurements per charge) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–50 °C |
| Relative Humidity | <85% RH (non-condensing) |
| Dimensions | 160 × 75 × 90 mm |
| Weight | 350 g |
| Software | OnShade QC Suite (GLP-compliant reporting, audit trail, export to CSV/PDF) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | UK |
| Model | LC100 & SV100 |
| Instrument Type | Portable |
| Optical Geometry | 45/0° integrating sphere |
| Light Source | Independent tri-directional 25-LED array (8 visible wavelengths + 1 UV LED) |
| Illuminant/Observer | D65/10° and A/10° |
| Spectral Range | 400–700 nm (visible) + UV channel |
| Repeatability | ≤0.1 ΔE94 (D65/10°, white tile) |
| Aperture Sizes | 4 mm and 8 mm |
| Measurement Time | ≤1.8 s |
| Standard Storage | 20 |
| Sample Storage | 350 |
| Display | 4.5 cm color TFT |
| Data Interface | USB mass storage mode |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–60 °C |
| Relative Humidity | 20–80% RH (non-condensing) |
| Altitude Limit | 2000 m |
| Pollution Degree | 2 |
| Overvoltage Category | II |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF229 |
| Light Source | CIE Illuminant C (Tungsten-Halogen Lamp) |
| Color Scale | AOCS Cc 13a-43 FAC Scale (Odd-Numbered, 1–50) |
| Viewing System | Triple-Field Visual Comparison |
| Compliance | AOCS Official Method Cc 13a-43 |
| Intended Use | Visual color assessment of dark oils, fats, tallow, lard, and rendered animal lipids |
| Brand | Shaw |
|---|---|
| Origin | United Kingdom |
| Model | SADP-D |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5) Sensor |
| Operating Temperature | -20 °C to +40 °C |
| Accuracy | ±3 °C to ±4 °C |
| Repeatability | ±0.5 °C |
| Dew Point Range | -100 °C to +20 °C |
| Display | Backlit LCD (°C/°F selectable) |
| Power Supply | Standard C-cell batteries |
| Battery Life | >150 hours continuous operation |
| Certification | ATEX II 2G Ex ia IIC T4 Ga, IECEx EXA 22.0001X |
| Calibration | NIST-traceable certificate included |
| Accessories | 2 m PTFE sampling hose, leather carry case with shoulder strap, desiccant-dried test chamber, user manual |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 1143 |
| Pricing | Upon Request |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF325 |
| Light Path | 113 mm |
| Standard Scale Range | 0–250 mg Pt/L (APHA/Hazen) |
| Compliant Standards | ASTM D1209, ISO 2211, ISO 6271, AOCS Td 1b-64, BS 5339 |
| Sample Compatibility | Clear, pale-yellow liquids |
| Calibration Method | Nessleriser 2150 comparator disc system |
| Scale Segments | NSH (10–90), NSB (70–250) |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF328 |
| Measuring Range | 0–70 mg Pt/L (Platinum-Cobalt Units) |
| Cell Path Length | 250 mm |
| Standard Discs | CAA (0–30 APHA), CAB (30–70 APHA) |
| Compliant Standards | ASTM D1209, ISO 2211, ISO 6271, AOCS Td 1b-64, BS 5339 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi995 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y coordinates |
| Measurement Time | <30 s |
| Optical Path Length | 0.1–153 mm |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| CIE Illuminants | A, B, C, D65 |
| Observer Angles | 2°, 10° |
| Data Storage Capacity | 100,000 measurements |
| Interface | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Optional Heater | Up to 95 °C |
| Operating Voltage | 90–240 VAC (external power supply) |
| Enclosure | Steel housing with textured epoxy coating |
| Dimensions & Weight | 515 × 195 × 170 mm / 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Lovibond RYBN, AOCS, Gardner, Pt-Co/Hazen/APHA, FAC, Chlorophyll A/B, β-Carotene, Iodine, Hess-Weis, Klett (Blue filter KS-42), Kreis, CIE XYZ/L*a*b*, spectral reflectance data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC3000 Saybolt |
| Measurement Range | –16 to +30 Saybolt |
| Resolution | 1 Saybolt Unit |
| Repeatability | ±1 Saybolt Unit |
| Path Length | 50 mm |
| Standard Compliance | ASTM D156, ASTM D6045 |
| Field of View | Triple-field viewing system |
| Cuvettes | Two 50 mm plastic cuvettes (W100), two 50 mm glass cuvettes (W100) |
| Calibration Standards | Two 60 mL certified reference liquids |
| Filter Set | Two calibrated interference filters |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1153 |
| Measurement Range | 0–2000 pS/m |
| Resolution | ±1 pS/m (0–2000 pS/m) |
| Accuracy | ±2% of reading |
| Operating Temperature | 0–50 °C |
| Display | 5-digit LCD with status text and LED illumination |
| Power | Three 3 V lithium batteries |
| Dimensions | 200.7 × 70 × 43.2 mm (L×W×D) |
| Probe Diameter | 19.05 mm |
| Weight | 365.8 g (12.9 oz) |
| Enclosure | Intrinsically Safe for Class I, Division 1, Group D hazardous locations |
| Compliance | ASTM D2624 |
| Optional Features | Temperature measurement mode, data hold, solvent-resistant hard-shell carrying case with O-ring sealed probe interface |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF650 |
| Measurement Range | 0.5–8.0 ASTM Colour Scale |
| Light Source | 12 V / 20 W Halogen Tungsten Lamp (CIE Illuminant C) |
| Viewing Geometry | Triple-Field Visual Comparison |
| Cell Path Length | 33 mm |
| Standard Discs | Two Rotating Glass Filter Discs (Disc 1: 0.5, 1.5, ..., 7.5 |
| Disc 2 | 1.0, 2.0, ..., 8.0) |
| Compliance | ASTM D1500, ISO 2049, IP 196, DIN 51578, BS 5859, JIS K 2580, NF T60-104, NBN T52-109, FTM 719-102 |
| Certification | CE |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi 950 |
| Compliance | ASTM D1209, ASTM D1500, ASTM D6045, AOCS Cd 13b-97, ISO 2761, ISO 4630, ISO 6271, Gardner ASTM D1544, Saybolt ASTM D156 |
| Measurement Principles | Transmission colorimetry using tungsten-halogen light source and precision interference filters |
| Display | High-resolution LCD with multilingual interface (including English & Chinese) |
| Sample Path Length Options | 10 mm, 20 mm, 33.3 mm, 50 mm, 100 mm |
| Output Data | CIE L*a*b*, CIE XYZ, CIE Yellowness Index (YI), Whiteness Index (WI), spectral reflectance/transmittance (380–720 nm, 10 nm intervals), and proprietary color scales |
| Connectivity | RS-232, USB, optional Ethernet |
| Software Compatibility | ColorSoft™ PC software for data export, audit trail, and report generation |
| Regulatory Support | FDA 21 CFR Part 11 compliant configuration available (with user authentication, electronic signatures, and full audit trail) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Model F |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Color Scale | Lovibond RYBN |
| Red Scale | 0.1–79.9 |
| Yellow Scale | 0.1–79.9 |
| Blue Scale | 0.1–49.9 |
| Neutral Scale | 0.1–3.9 |
| Resolution | 0.1 Lovibond Unit |
| Light Source | Dual 12 V / 10 W Tungsten-Halogen Lamps |
| Illuminant Compliance | CIE Standard Illuminant C |
| Sample Chamber | Removable White Liner with Precision-Registered Cell Notch |
| Power Supply | External Low-Voltage DC Adapter |
| Brand | Lovibond |
|---|---|
| Origin | United Kingdom |
| Model | TG60 |
| Measurement Angle | 60° |
| Compliant Standards | ISO 2813, ASTM D523, ASTM D2457, GB/T 9754 |
| Measuring Area | 9 mm × 15 mm |
| Gloss Range | 0–300 GU |
| Resolution | 0.1 GU |
| Repeatability | ±0.1 GU (0–10 GU), ±0.2 GU (10–100 GU), ±0.2% GU (100–300 GU) |
| Reproducibility | ±0.2 GU (0–10 GU), ±0.5 GU (10–100 GU), ±0.5% GU (100–300 GU) |
| Illuminant | CIE Standard Illuminant C |
| Observer Angle | 2° |
| Measurement Time | 0.5 s |
| Dimensions | 160 mm × 75 mm × 90 mm |
| Weight | 350 g |
| Display | 3.5-inch TFT capacitive touchscreen |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–50 °C |
| Relative Humidity | <85% RH (non-condensing) |
| Power | Rechargeable 3200 mAh Li-ion battery (up to 10,000 measurements per charge) |
| Interface | USB & RS-232 |
| Data Storage | 1,000 readings (basic mode) |
| Software | OnShade QC software with GLP-compliant reporting and export functionality |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1140 |
| Compliance | ASTM D3948, ASTM D4860 |
| Design | Integrated portable analyzer with built-in audio-guided test protocol |
| Test Duration | 5–10 minutes per sample |
| Sample Volume | Low-consumption (≤50 mL typical) |
| User Interface | Touch-sensitive control panel |
| Test Kit | Standard six-piece test assembly (pre-calibrated, disposable-compatible) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | TYS-3672A |
| Pricing | Upon Request |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/2 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| Illuminants | CIE A, B, C, D65 |
| Observer Angles | 2° and 10° |
| Pathlength Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Internal Memory | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing | Powder-coated steel enclosure |
| Dimensions & Weight | 435 × 195 × 170 mm / 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Saybolt (ASTM D6045/D156), ASTM D1500, Pt-Co/Hazen/APHA (ASTM D1209), CIE XYZ/Lab values, spectral reflectance data |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | 1154 |
| Detection Parameter | Single (Conductivity) |
| Portability | Benchtop |
| Application Environment | Laboratory |
| Conductivity Range | 0–20,000 pS/m |
| Accuracy | ±½% of reading |
| Minimum Resolution | 0.01 pS/m |
| Brand | Lovibond |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/3 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability (CIE x,y) | ±0.0004 |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Observer Angles | 2°, 10° |
| Path Length Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Data Storage Capacity | 100,000 measurements |
| Display | 240 × 128 pixel backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Housing Material | Steel enclosure with textured epoxy coating |
| Dimensions (W×H×D) | 435 × 195 × 170 mm |
| Weight | 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC3000 ASTM |
| Measurement Range | 0–8 ASTM units |
| Resolution | 0.1 unit |
| Repeatability | ±0.1 unit |
| Path Length | 33 mm |
| Standard Compliance | ASTM D1500, ASTM D6045 |
| Field of View | 3-field |
| Cuvette Types | Two 33 mm plastic cuvettes (W100), Two 33 mm glass cuvettes (W100) |
| Calibration Standards | Two 60 mL reference liquid standards |
| Filter Set | Two certified interference filters |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | TR 520 / TR 500 |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Combined LED + UV |
| Spectral Range | 400–700 nm |
| Repeatability | TR520 (MAV/SCI): ΔE* ≤ 0.03 |
| TR500 (MAV/SCI) | ΔE* ≤ 0.05 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi 950/P |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Path Length Range | 0.1–153 mm (0.004–6 in) |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Built-in Color Scales | ASTM D1500 (Petroleum), Saybolt, CIE L*a*b*, L*C*h*, Yellowness Index (ASTM E313), Whiteness Index (CIE/ISO 11475), and Spectral Data Output |
| Calibration | One-Touch Automatic Baseline Calibration |
| Data Storage Capacity | 100,000 measurements |
| Interface Options | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile membrane keys with audible feedback, polyester overlay |
| Operating Languages | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Housing | Steel chassis with textured epoxy coating |
| Dimensions (W×H×D) | 515 × 195 × 170 mm |
| Weight | 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Optional Heated Cell Holder | Up to 95 °C temperature control |
| Brand | Teledyne Cetac |
|---|---|
| Origin | USA |
| Model | 3110 |
| Measurement Range | 0–10 ppm to 0–25% O₂ |
| Output | 0–1 VDC analog |
| Sensor Type | Electrochemical fuel cell (B-2C for trace, B-1 for percent) |
| Response Time | <60 s (trace), <7 s (percent) |
| Operating Temperature | 0–40°C |
| Repeatability | ±1% of reading |
| Power | Rechargeable NiCd battery (>100 h per charge, 5-year service life) + AC adapter (110/220 VAC, 50/60 Hz) |
| Weight | 2.71 kg (6 lbs) |
| Certifications | FM/FMc Class I Div 1 Groups A–D T6, ATEX Ex ia IIC T3, CE marked |
| Ingress Protection | Not specified |
| Data Logging | Integrated |
| Safety Rating | Intrinsically safe |
Show next