BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelBSD-PHD
Measurement MethodVolumetric (Static Capacity) Method
Temperature Range–196 °C to 1100 °C
Pressure Range0–20 MPa
Ultimate Vacuum / Maximum PressureUp to 690 bar (69 MPa)
Repeatability Error< ±2%
Pressure Sensor Accuracy±0.01% FS, Long-term Stability: ±0.025% FS
Air-Bath Temperature Control40.0 °C ±0.1 °C
SafetyIntegrated combustible gas alarm, high-pressure integrity tested, optional alarm interlock system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelBSD-PHC
Pricing RangeUSD 70,000 – 140,000 (FOB)
Measurement MethodStatic Volumetric Method
Temperature RangeAmbient to 80 °C (standard)
Pressure RangeAdsorption: 0–20 MPa (standard), 0–50 MPa / 0–69 MPa (optional)
Confining (Cladding) Pressure0–50 MPa / 0–70 MPa (optional)
Ultimate Vacuum<1×10⁻⁶ mbar (equivalent to full-scale 690 bar operation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelBSD-PHU
Testing MethodStatic Volumetric Method
Temperature Range–196 °C to 80 °C (standard)
Pressure RangeHigh vacuum to 700 bar (70 MPa)
Ultimate Vacuum1×10⁻² to 1×10⁻⁶ Pa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelBSD-MAB
Price RangeUSD 70,000 – 140,000 (FOB China)
Gas Mixture CompatibilityBinary and multicomponent gas–gas, gas–vapor, vapor–vapor systems
Mass Flow Controllers (MFCs)4–8 independently programmable channels
Breakthrough ColumnsStandard stainless-steel columns (2 mL and 8 mL volumes)
Adsorption Pressure RangeAmbient to 10 MPa (optional high-pressure modules: up to 1 MPa or 3 MPa)
Adsorption Temperature ControlCirculating water bath (−20 °C to 80 °C, ±0.1 °C stability)
High-Temperature FurnaceAmbient to 600 °C (customizable beyond)
Detection SystemsIntegrated thermal conductivity detector (TCD)
Detection LimitsTVOC: 5 × 10⁻¹² g/mL
SO₂14 × 10⁻¹² g/mL
NH₃16 × 10⁻¹² g/mL
Vapor Generation SystemP/P₀ control range 0.1%–99.99%, accuracy ±1%
Vacuum Activation<0.1 Pa base pressure
Corrosive Gas CompatibilitySO₂, NH₃, organic vapors (compatible with fluorocarbon-sealed components)
Regulatory Compliance SupportASTM D5228, ISO 12213-2, USP <621>, GLP-compliant data audit trail (via optional software module), FDA 21 CFR Part 11-ready configuration available
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Beishide Instrument
OriginBeijing, China
ManufacturerYes
TypeDomestic
ModelBSD-PB
Price RangeUSD 14,000 – 42,000
Pore Size Range (Gas-Liquid)0.02–500 µm
Pore Size Range (Liquid-Liquid)5–500 nm
Vacuum-Assisted WettingIntegrated automatic system
Dual Pressure Sensors0–1 bar & 0–40 bar, ±0.05 mbar accuracy
Dual Flow Sensors0–1 L/min & 0–200 L/min, ±0.1 mL/min accuracy
ComplianceGB/T 32361-2015, ASTM F316-03, ASTM D6767-02, ISO 2942, DIN ISO 4003, BS 7591-4, HY/T 051, HY/T 064
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBSD-MAB1
Gas RangeBinary & Ternary Mixtures Including Gas/Gas, Gas/Vapor, Vapor/Vapor
MFC Channels4–8
Breakthrough ColumnsStandard 2 mL & 8 mL Stainless Steel or Quartz Columns (Custom Volumes Available)
Adsorption PressureAmbient to 10 MPa
Adsorption TemperatureCirculating Water Bath (−20 °C to 80 °C), High-Temperature Furnace (RT to 600 °C
Detector OptionsIntegrated TCD, Optional Online GC or Mass Spectrometer (MS)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
Model3H-2000PWP
Instrument TypeStatic/Dynamic Vapor Adsorption Analyzer
Measurement PrincipleKnudsen Effusion Mass Loss Method
Analysis Stations2 sample + 2 reference stations (4 total)
Sample Mass Range10–1000 mg
Mass Resolution1 µg
Vacuum SystemDual-stage mechanical pump (1×10⁻² Pa) + turbomolecular pump (1×10⁻⁶ Pa)
Pressure Range0–1 torr & 0–1000 torr (dual-range, segmented)
Temperature Range–180 °C to 900 °C (accuracy ±0.1 °C, stability <0.1 °C)
Isothermal Control RangeAmbient to 60 °C (accuracy ±0.2 °C, stability <0.1 °C)
Temperature Program32-segment ramping with overheat protection
SealingOil-resistant & corrosion-resistant valve and tubing system
DimensionsH110 × W100 × L70 cm
Weight200 kg