- All
- Favorite
- Popular
- Most rated
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | BSD-PHD |
| Measurement Method | Volumetric (Static Capacity) Method |
| Temperature Range | –196 °C to 1100 °C |
| Pressure Range | 0–20 MPa |
| Ultimate Vacuum / Maximum Pressure | Up to 690 bar (69 MPa) |
| Repeatability Error | < ±2% |
| Pressure Sensor Accuracy | ±0.01% FS, Long-term Stability: ±0.025% FS |
| Air-Bath Temperature Control | 40.0 °C ±0.1 °C |
| Safety | Integrated combustible gas alarm, high-pressure integrity tested, optional alarm interlock system |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-PHC |
| Pricing Range | USD 70,000 – 140,000 (FOB) |
| Measurement Method | Static Volumetric Method |
| Temperature Range | Ambient to 80 °C (standard) |
| Pressure Range | Adsorption: 0–20 MPa (standard), 0–50 MPa / 0–69 MPa (optional) |
| Confining (Cladding) Pressure | 0–50 MPa / 0–70 MPa (optional) |
| Ultimate Vacuum | <1×10⁻⁶ mbar (equivalent to full-scale 690 bar operation) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BSD-PHU |
| Testing Method | Static Volumetric Method |
| Temperature Range | –196 °C to 80 °C (standard) |
| Pressure Range | High vacuum to 700 bar (70 MPa) |
| Ultimate Vacuum | 1×10⁻² to 1×10⁻⁶ Pa |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BSD-MAB |
| Price Range | USD 70,000 – 140,000 (FOB China) |
| Gas Mixture Compatibility | Binary and multicomponent gas–gas, gas–vapor, vapor–vapor systems |
| Mass Flow Controllers (MFCs) | 4–8 independently programmable channels |
| Breakthrough Columns | Standard stainless-steel columns (2 mL and 8 mL volumes) |
| Adsorption Pressure Range | Ambient to 10 MPa (optional high-pressure modules: up to 1 MPa or 3 MPa) |
| Adsorption Temperature Control | Circulating water bath (−20 °C to 80 °C, ±0.1 °C stability) |
| High-Temperature Furnace | Ambient to 600 °C (customizable beyond) |
| Detection Systems | Integrated thermal conductivity detector (TCD) |
| Detection Limits | TVOC: 5 × 10⁻¹² g/mL |
| SO₂ | 14 × 10⁻¹² g/mL |
| NH₃ | 16 × 10⁻¹² g/mL |
| Vapor Generation System | P/P₀ control range 0.1%–99.99%, accuracy ±1% |
| Vacuum Activation | <0.1 Pa base pressure |
| Corrosive Gas Compatibility | SO₂, NH₃, organic vapors (compatible with fluorocarbon-sealed components) |
| Regulatory Compliance Support | ASTM D5228, ISO 12213-2, USP <621>, GLP-compliant data audit trail (via optional software module), FDA 21 CFR Part 11-ready configuration available |
| Key | Brand: Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | BSD-PB |
| Price Range | USD 14,000 – 42,000 |
| Pore Size Range (Gas-Liquid) | 0.02–500 µm |
| Pore Size Range (Liquid-Liquid) | 5–500 nm |
| Vacuum-Assisted Wetting | Integrated automatic system |
| Dual Pressure Sensors | 0–1 bar & 0–40 bar, ±0.05 mbar accuracy |
| Dual Flow Sensors | 0–1 L/min & 0–200 L/min, ±0.1 mL/min accuracy |
| Compliance | GB/T 32361-2015, ASTM F316-03, ASTM D6767-02, ISO 2942, DIN ISO 4003, BS 7591-4, HY/T 051, HY/T 064 |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BSD-MAB1 |
| Gas Range | Binary & Ternary Mixtures Including Gas/Gas, Gas/Vapor, Vapor/Vapor |
| MFC Channels | 4–8 |
| Breakthrough Columns | Standard 2 mL & 8 mL Stainless Steel or Quartz Columns (Custom Volumes Available) |
| Adsorption Pressure | Ambient to 10 MPa |
| Adsorption Temperature | Circulating Water Bath (−20 °C to 80 °C), High-Temperature Furnace (RT to 600 °C |
| Detector Options | Integrated TCD, Optional Online GC or Mass Spectrometer (MS) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | 3H-2000PWP |
| Instrument Type | Static/Dynamic Vapor Adsorption Analyzer |
| Measurement Principle | Knudsen Effusion Mass Loss Method |
| Analysis Stations | 2 sample + 2 reference stations (4 total) |
| Sample Mass Range | 10–1000 mg |
| Mass Resolution | 1 µg |
| Vacuum System | Dual-stage mechanical pump (1×10⁻² Pa) + turbomolecular pump (1×10⁻⁶ Pa) |
| Pressure Range | 0–1 torr & 0–1000 torr (dual-range, segmented) |
| Temperature Range | –180 °C to 900 °C (accuracy ±0.1 °C, stability <0.1 °C) |
| Isothermal Control Range | Ambient to 60 °C (accuracy ±0.2 °C, stability <0.1 °C) |
| Temperature Program | 32-segment ramping with overheat protection |
| Sealing | Oil-resistant & corrosion-resistant valve and tubing system |
| Dimensions | H110 × W100 × L70 cm |
| Weight | 200 kg |
Show next