Empowering Scientific Discovery

Beishide Instrument Technology (Beijing) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeAutomated Chemisorption Analyzer
Test PrincipleContinuous Flow Method
Gas Inlet Ports12 channels
Heating Temperature RangeAmbient to 1200 °C
Isothermal StabilityAmbient to 60 °C
Ramp Rate1–100 °C/min
Pressure OptionsAtmospheric (standard), optional up to 10 MPa
Core FunctionsTPD, TPR, TPO, TPSR, TPS, Pulse Titration, Desorption Kinetics (Ed, Ad, n), Adsorption Kinetics (Ea, ΔH, Aa)
Optional CouplingOnline MS (INFICON), FT-IR (Thermo Fisher Nicolet iS20/iS5)
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Beishide Instrument
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
ModelBSD-VVS&DVS
Weighing Resolution1 µg / 2000 mg (0.1 µg / 100 mg optional)
Weighing Range1 µg to 2000 mg (customizable up to 5000 mg)
Temperature Range−180 °C to 50 °C (accuracy ±0.1 °C, stability <0.1 °C)
Relative Humidity Range0.01–98% P/P₀
Humidity Accuracy<0.001 torr (7×10⁻⁶ mbar)
Sorption ModesStatic (vacuum) & Dynamic (flow-through) gravimetric
Analysis Stations4 or 8 independent, fully synchronized positions
Gas/Vapor CompatibilityH₂O, organic vapors, CO₂, alkanes/alkenes
Vacuum SystemDual-pump configuration (mechanical + vapor pump)
Pressure SensingDual capacitive diaphragm gauges (segmented range)
Flow ControlHigh-precision mass flow controllers (MFCs)
Thermal ManagementFull-path thermostating (vapor lines, sample chamber, balance enclosure)
Software ComplianceAudit trail, user access control, electronic signatures per FDA 21 CFR Part 11
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelBSD-MAB
Price RangeUSD 70,000 – 140,000
Gas Mixture CompatibilityGas–Gas, Gas–Vapor, Vapor–Vapor
Mass Flow Controllers (MFCs)4–8 units
Breakthrough Column OptionsStandard 2 mL and 8 mL packed columns
Adsorption Pressure RangeAmbient to 10 MPa
Adsorption Temperature RangeCirculating water bath: −20 °C to 80 °C
High-temperature furnaceAmbient to 600 °C
Detection SystemsIntegrated online quadrupole mass spectrometer (QMS)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelBSD-660A6B3M
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Measurement PrincipleStatic Volumetric Method
Number of Analysis Stations3 / 6 / 9 / 12 (configurable)
Surface Area Range≥0.0005 m²/g
Pore Diameter Range0.35–500 nm
Repeatability<0.5% RSD (standard reference material)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelBSD-PMV
Instrument TypeStatic Vapor Adsorption Analyzer
Mass Resolution0.01 µg
Mass Range0.001 g
Temperature Range0–105 °C
Relative Humidity Range0.01–98 % P/P₀
Humidity AccuracyBetter than 0.001 torr (7×10⁻⁶ mbar)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Regional CategoryDomestic (China)
ModelBSD-PBB
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelBSD-660
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Measurement PrincipleStatic Volumetric Method
Number of Analysis Stations3 / 6 / 9 / 12 configurable
Pore Size Range0.35–500 nm
Analytical Theories SupportedBET surface area, BJH pore size distribution (mesopores), DR & HK (Original) micropore analysis, DFT-based pore modeling, IASTL multi-component adsorption modeling
Repeatability≤0.5% RSD (certified standard reference materials)
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Beishide Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelBSD-660M
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Measurement PrincipleStatic Volumetric Method
Number of Analysis Stations12
Pore Size Range0.35–500 nm
Pressure Rangedown to 1 × 10⁻⁹ Pa
Analytical TheoryStatic Gravimetric/Volumetric Adsorption
Repeatability≤0.01% RSD (on certified reference materials)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelBSD-660 Series
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Measurement PrincipleStatic Volumetric Method
Number of Analysis Stations3 / 6 / 9 / 12 configurable
Surface Area Range≥0.0005 m²/g
Pore Diameter Range0.35–500 nm
Pressure Range10⁻² Pa (standard)
Test TheoryStatic Volumetric Adsorption
Repeatability≤1% RSD
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Beishide Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Volumetric Gas Adsorption
Analysis Stations6 Mesopore Stations + 6 Micropore Stations
Surface Area Range≥0.0005 m²/g
Pore Diameter Range0.35–500 nm
Vacuum Level≤10⁻² Pa (standard), optional molecular pump for ≤10⁻⁸ Pa
Repeatability≤1% RSD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic
ModelBSD-660MG
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Measurement PrincipleStatic Volumetric Method
Number of Analysis Stations3 / 6 / 9 / 12 (configurable)
Specific Surface Area Range≥0.0005 m²/g
Pore Diameter Range0.35–500 nm
Pressure RangeAmbient pressure (up to 1000 torr) with ultra-low-pressure capability down to P/P₀ = 1×10⁻⁸
RepeatabilityQuantitative error <0.5% RSD (BET standard reference material)
Vacuum SystemTurbo-molecular pump achieving ultimate vacuum ≤1×10⁻⁸ Pa
Gas CompatibilityN₂, O₂, Ar, CO, CO₂, H₂, CH₄, C₂H₆ (non-corrosive & flammable gases)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
ModelBSD-660A6S
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Volumetric Method (Static Capacity Method)
Analysis Stations3 / 6 / 9 / 12 configurable
Surface Area Range≥0.0005 m²/g
Pore Diameter Range0.35–500 nm
Pressure Range0–1000 torr & 0–1 torr (dual-range transducers)
Repeatability≤0.5% RSD (certified reference material)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelBSD-PBx
Price RangeUSD 14,000 – 42,000 (FOB)
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Operating PrincipleStatic Gas Pressure Method (Bubble Point & Gas Flow)
Number of Analysis Stations1
Pore Size Range0.02 – 500 µm
Pressure Range0–1 bar & 0–40 bar (dual-range, auto-switching)
Test TheoryGas Bubble Point Method
Repeatability±0.01 µm (on certified reference membranes)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeChemisorption Analyzer
ModelBSD-Chem C200
Testing PrincipleContinuous Flow Method
Gas Inlet Channels12
Heating Temperature RangeAmbient to 1200 °C
Isothermal StabilityAmbient to 60 °C
Heating Rate1–100 °C/min
Pressure OptionsAtmospheric (standard), optional 1 MPa / 3 MPa / 10 MPa
Core FunctionsTPD, TPR, TPO, TPSR, TPS, Pulse Titration, Desorption Kinetics (Ed, Ad, n), Adsorption Kinetics (Ea, ΔH, Aa)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
Model3H-2000PWP2
Price RangeUSD 70,000–140,000
Instrument TypeStatic/Dynamic Vapor Adsorption Analyzer
Measurement PrincipleKnudsen Effusion Mass Loss Method
Analysis Stations2 sample + 2 reference stations (total 4)
Sample Mass Range10–1000 mg
Mass Resolution1 µg
Vacuum SystemDual-stage mechanical pump (base pressure ≤ 1×10⁻² Pa) + turbo-molecular pump (base pressure ≤ 1×10⁻⁶ Pa)
Pressure Range0–1 torr & 0–1000 torr (dual-range, segmented measurement)
Temperature Range–180 °C to 900 °C (accuracy ±0.1 °C, stability < 0.1 °C)
Isothermal Control RangeAmbient to 60 °C (accuracy ±0.2 °C, stability < 0.1 °C)
Temperature Programming32-segment ramping with overtemperature protection
Sealing DesignOil-resistant, corrosion-resistant valves and tubing
DimensionsH 110 cm × W 100 cm × L 70 cm
Weight200 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Instrument TypeSpecific Surface Area and Pore Size Analyzer
ModelBSD-660A3M
Analysis Stations3 / 6 / 9 / 12
Surface Area Range≥0.0005 m²/g
Pore Diameter Range0.35–500 nm
Vacuum Level≤1×10⁻² Pa (standard), optional turbomolecular pump for ≤1×10⁻⁸ Pa
Measurement PrincipleStatic Volumetric Gas Adsorption
Repeatability<0.5% RSD for surface area, pore size, pore volume, and adsorbed quantity (certified reference materials)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Product CategoryDomestic
ModelBSD-660A3MB3M
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Measurement PrincipleStatic Volumetric Gas Adsorption
Number of Analysis Stations3 / 6 / 9 / 12 configurable
Surface Area Range≥ 0.0005 m²/g
Pore Diameter Range0.35–500 nm
Vacuum LevelStandard: 1×10⁻² Pa
Optional Turbo-Molecular Pump≤ 1×10⁻⁸ Pa
Repeatability< 0.5% RSD (certified reference material)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
ModelBSD-660H
Measurement MethodStatic Volumetric Method
Temperature Range−196 °C to 300 °C (extendable to 1100 °C with optional furnace)
Pressure RangeHigh vacuum to 690 bar (69 MPa)
Ultimate Vacuum1 × 10⁻⁷ mbar
Repeatability< ±2%
Pressure Sensor Accuracy±0.01% FS
Air-Bath Temperature Control40.0 °C ± 0.1 °C
SafetyIntegrated combustible gas alarm, pressure-tested gas circuitry, optional alarm interlock system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument CategoryDomestic
ModelBSD-660A3S
Instrument PrincipleStatic Volumetric Gas Adsorption
Number of Analysis Stations3 / 6 / 9 / 12
Pore Size Range0.35–500 nm
Specific Surface Area Range≥0.0005 m²/g
Vacuum Level≤1×10⁻⁹ Pa
Temperature Control Accuracy±0.1 °C (RT–400 °C)
Quantitative Repeatability<0.5% RSD (BET standard reference material)
Adsorption GasesN₂, O₂, Ar, CO, CO₂, H₂, CH₄, C₂H₆ (non-corrosive & combustible)
Optional Thermal Control–10–80 °C (with恒温 water bath) or 100 K–RT (with LNT level stabilization)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Regional CategoryDomestic (China)
ModelBSD-660A3M / BSD-660B3M
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Volumetric Method (Static Capacity Method)
Number of Analysis Stations3 / 6 / 9 / 12
Surface Area Range≥0.0005 m²/g (no upper limit)
Pore Diameter Range0.35–500 nm (Micropores: 0.35–2 nm
Mesopores2–50 nm
Macropores50–500 nm)
Total Pore Volume Range≥0.0001 cm³/g (no upper limit)
Pressure Ranges0–1000 torr, 0–1 torr, 0–0.1 torr (selectable)
Repeatability≤±1.0%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Product CategoryDomestic
ModelBSD-Chem C200
Instrument TypeChemisorption Analyzer
Measurement PrincipleContinuous Flow Method
Gas Inlet Ports12 channels
Heating Temperature RangeAmbient to 1200 °C
Isothermal Stability±0.1 °C from ambient to 60 °C
Ramp Rate1–100 °C/min
Pressure RangeAtmospheric (standard)
Test Capabilities1. Temperature-Programmed Desorption (TPD), 2. Temperature-Programmed Reduction (TPR), 3. Temperature-Programmed Oxidation (TPO), 4. Temperature-Programmed Surface Reaction (TPSR), 5. Temperature-Programmed Sulfidation (TPS), 6. Pulse Titration, 7. Desorption Activation Energy (E<sub>d</sub>), 8. Pre-exponential Factor for Desorption (A<sub>d</sub>), 9. Desorption Order (n), 10. Adsorption Activation Energy (E<sub>a</sub>), 11. Enthalpy of Adsorption (ΔH), 12. Pre-exponential Factor for Adsorption (A<sub>a</sub>)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
ModelBSD-PAGP
Pricing RangeUSD 70,000 – 140,000 (FOB)
Measurement MethodStatic Volumetric Method
Temperature Range−10 °C to +80 °C (±0.1 °C stability)
Pressure Range0–69 MPa
Ultimate Vacuum1×10⁻² to 1×10⁻⁶ Pa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Volumetric Method (Static Capacity Method)
Analysis Stations3 / 6 / 9 / 12 configurable
Surface Area Range≥0.0005 m²/g
Pore Diameter Range0.35–500 nm
Repeatability±0.01 (RSD)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeishide Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
Instrument TypeSpecific Surface Area and Pore Size Analyzer
ModelBSD-660A6M
Measurement PrincipleStatic Volumetric Method
Number of Analysis Stations3 (micro-pore configuration)
Surface Area Range≥0.0005 m²/g
Pore Diameter Range0.35–500 nm
Vacuum Level≤1×10⁻² Pa (standard), optional turbo-molecular pump for ≤1×10⁻⁸ Pa
Repeatability≤1% RSD
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0