| Brand | Grant Instruments (UK) |
|---|---|
| Origin | United Kingdom |
| Model | OLS26 |
| Instrument Type | Water Bath Orbital-Reciprocating Shaker |
| Timer Range | 1–999 min |
| Oscillation Speed | 20–200 rpm |
| Amplitude Options | 18 / 28 / 36 mm (linear), 9 mm (orbital) |
| Temperature Range | Ambient +5°C to 99°C (0°C with optional CC26 chiller) |
| Temperature Stability & Uniformity | ±0.1°C @ 37°C |
| Bath Capacity | 26 L |
| Heating Technology | HeatMat™ embedded heating film |
| Control System | Digital PID with Set-and-Forget™ algorithm |
| Safety Features | Over-temperature protection, dry-run detection, low-level fluid alarm, programmable safety cutoff |
| Power Supply | 230 V, 1.15–1.5 kW |
| Drain Valve | Quick-connect push-pull type |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | OLS26 |
| Temperature Range | 0–99 °C (with optional refrigeration to 0 °C) |
| Timing Range | 1–999 min |
| Oscillation Speed | 20–200 rpm |
| Orbital Amplitude | 9 mm |
| Reciprocating Stroke | 18/28/36 mm |
| Bath Capacity | 26 L |
| Temperature Uniformity & Stability | ±0.1 °C @ 37 °C |
| Display Resolution | 0.1 °C |
| Heating Method | HeatMat™ polymer heating film |
| Control System | Digital PID with Set-and-Forget™ algorithm |
| Safety Features | Over-temperature protection, dry-run detection, low-level fluid alarm, programmable safety cutoff |
| Power Supply | 230 V, 1.15–1.5 kW |
| Construction | Electropolished stainless steel bath chamber with quick-connect drain valve |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | P12-100 |
| Instrument Type | Accessory Tray for Orbital Shakers |
| Timer Range | Not Applicable (Passive Tray) |
| Oscillation Frequency | Not Applicable |
| Oscillation Amplitude | Not Applicable |
| Temperature Range | Not Applicable |
| Number of Platforms | 1 |
| Brand | Grant Instruments |
|---|---|
| Origin | United Kingdom |
| Model | PCMT |
| Instrument Type | Benchtop Thermo-Mixer with Active Cooling |
| Temperature Range | +4 °C to +100 °C |
| Temperature Uniformity | ±0.1 °C |
| Heating Rate (HC15 module) | 5 °C/min (25 °C → 100 °C) |
| Cooling Rate (HC15 module) | 5 °C/min (100 °C → 25 °C) |
| Oscillation Speed | 250–1400 rpm |
| Speed Resolution | 1 rpm |
| Orbit Diameter | 2 mm |
| Timer Range | 1 min – 96 h (1-min increments, audible alarm, auto-shutdown) |
| Plate Capacity | 1 × standard microplate (96-well, 0.2 mL) or equivalent tube configurations |
| Dimensions (W×D×H) | 250 mm × 230 mm × 130 mm |
| Weight | 4 kg |
| Power Supply | 120 V or 230 V AC, 50/60 Hz |
| Input Current | 4.16 A |
| Brand | Grant |
|---|---|
| Origin | UK |
| Model | PHMP |
| Temperature Range | RT+5 to 60 °C |
| Temp Stability | ±0.1 °C |
| Temp Uniformity | ±0.2 °C |
| Shaking Speed | 250–1200 rpm |
| Speed Resolution | 10 rpm |
| Orbit Diameter | 4 mm (2 mm radius) |
| Timer Range | 1 min – 96 h |
| Timer Resolution | 1 min |
| Display | 2×16-character LCD |
| Heating Time (to 37 °C) | 15–20 min |
| Dimensions (W×D×H) | 265×250×125 mm |
| Ambient Operating Temp | 4–45 °C |
| Input | 12 V DC, 5 A |
| Plate Compatibility | 96-well and 384-well microplates |
| Configurations | PHMP (2-plate capacity), PHMP-4 (4-plate capacity, optional high-temp variant: 5–100 °C) |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | PMR-100 |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Frequency | 1–100 rpm |
| Adjustable Tilt Angle | 0°–10° (1° increments) |
| Operating Temperature Range | +4 °C to +40 °C |
| Power Supply | 12 V DC |
| Max Load per Platform | >5 kg |
| Platform Dimensions | 460 mm × 360 mm |
| Display | 2-line, 16-character LCD |
| Noise Level | Low (motor optimized for quiet operation in controlled environments) |
| Platform Quantity | ≥4 independent platforms |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PMR-100 |
| Price Range | USD 2,700 – 6,800 (est.) |
| Instrument Type | Orbital/Platform Rocker |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Frequency | 1–100 rpm |
| Rocking Angle | 0°–10° (adjustable in 1° increments |
| Temperature Operating Range | +4 °C to +40 °C |
| Number of Platforms | 4 |
| Power Supply | 12 V DC |
| Max Load per Platform | >5 kg |
| Display | 2-line × 16-character LCD |
| Noise Level | Low (<45 dB(A)) |
| Compliance | CE, RoHS, IEC 61010-1 |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PMR-30 |
| Price | Upon Request |
| Speed Range | 7.5–30 rpm |
| Fixed Tilt Angle | 7° |
| Max Load Capacity | 0.5 kg |
| Operating Modes | Timer Mode or Continuous Operation |
| Timer Range | 1 min – 24 h |
| Platform Dimensions | 210 × 210 mm |
| Display | 4-digit LED |
| Operating Temperature | 4–40 °C |
| Power Supply | 12 V DC |
| Current Draw | 0.5 A |
| Compatible Accessories | PTP-26 Microtube Adapter (26 × 11 mm), PDM Non-slip Mat |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | PS-3D |
| Speed Range | 15–30 rpm |
| Tilt Angle | 7° |
| Max Load Capacity | 0.5 kg |
| Platform Dimensions | 200 × 200 mm |
| Operating Temperature | 4–40 °C |
| Power Supply | 12 V DC |
| Current Draw | 0.5 A |
| Noise Level | Low |
| Compliance | CE, RoHS |
| Standard Accessories | Non-slip mat (PDM) |
| Optional Accessories | PTP-26 microtube adapter (26 × 11 mm) |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PS-M3D |
| Price | Upon Request |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | PSU-10i |
| Timer Range | 1 min to 96 h |
| Oscillation Speed | 50–450 rpm |
| Orbit Diameter | 10 mm |
| Maximum Load Capacity | 3.0 kg |
| Platform Type | Single removable platform |
| Operating Temperature Range | 4–40 °C |
| Power Supply | 12 V DC |
| Display | Dual-line 16-character LCD |
| Noise Level | <45 dB(A) |
| Compliance | CE, RoHS, UKCA |
| Platform Compatibility | Standard flat platform (optional platforms: MPP-4 microplate holder, universal bottle tray, flask clamp set, and custom silicone mat) |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | PSU-20 |
| Orbit Diameter | 20 mm |
| Speed Range | 20–250 rpm |
| Max Load Capacity | 8 kg |
| Oscillation Modes | Orbital, Reciprocal, Vibration |
| Reciprocal Angle Range | 0–360° |
| Vibration Tilt Angle | 0–5° |
| Pulse Duration (Vibration Mode) | 0–5 s |
| Timer Range | 1 min–96 h (Auto-Off) |
| Display | Dual-line 16-character LCD |
| Input | 12 V DC, 4.16 A |
| Operating Temperature | 5–40 °C |
| Dimensions (W×D×H) | 520 × 485 × 140 mm |
| Compatible Platforms | PUP-400, PP-20, P30-100, P16-250, P9-500, P6-1000 |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | PSU-20i |
| Timer Range | 1 min to 96 h |
| Oscillation Speed | 20–250 rpm |
| Motion Amplitude | 360° (orbital), 30–360° (reciprocal), 0–5° (vibrational) |
| Platform Type | Single removable platform |
| Max Load Capacity | 8 kg |
| Drive System | Brushless DC motor |
| Display | 2-line × 16-character LCD |
| Power Supply | 12 V DC, 4.1 A |
| Operating Ambient Temperature | 4–40 °C |
| Compliance | CE, RoHS, UKCA |
| Brand | Grant Instruments |
|---|---|
| Origin | United Kingdom |
| Model | PSU-20i |
| Timer Range | 1 min – 96 h (auto-off) |
| Oscillation Frequency | 20–250 rpm |
| Orbital Diameter | 20 mm |
| Maximum Load Capacity | 8 kg |
| Number of Shaking Platforms | 3 |
| Temperature Range | Ambient (5–40 °C) |
| Vibration Mode Pulse Duration | 0–5 s |
| Reciprocating Mode Angle | 0–360° |
| Vibration Mode Tilt Angle | 0–5° |
| Input Voltage | 12 V DC |
| Dimensions (W×D×H) | 520 × 485 × 140 mm |
| Display | Dual-line 16-character LCD |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | PTR-25 |
| Instrument Type | End-Over-End Rotator |
| Timer Range | 1 min – 24 h |
| Oscillation Speed | 5–30 rpm |
| Rotation Angle | 360° |
| Operating Temperature Range | +4 °C to +40 °C |
| Platform Quantity | 1 |
| Maximum Load Capacity | 0.5 kg |
| Tube Compatibility | Up to 22 × Ø15 mm tubes (1.5–15 mL) |
| Power Supply | 12 V DC |
| Current Draw | 0.5 A |
| Display | LED |
| Brand | Grant Instruments |
|---|---|
| Origin | United Kingdom |
| Model | PTR-35 |
| Instrument Type | Inversion Shaker |
| Timer Range | 1 min to 24 h |
| Oscillation Speed | 1–100 rpm |
| Rotation Amplitude | 360° |
| Temperature Control | Ambient Only |
| Platform Quantity | 1 |
| Platform Capacity | 26 × 15 mm microtubes |
| Programmable Modes | Vertical Rotation, Reciprocal Rocking, Pulsed Vibration |
| Speed Resolution | 1 rpm |
| Timer Resolution (Rotational Modes) | 1–250 s |
| Timer Resolution (Vibration Mode) | 1–5 s |
| Pause Duration | 1–5 s |
| Cycle Count | 1–125 |
| Display | 2×16-character LCD |
| Input Voltage | 12 V DC |
| Max Load | 1.0 kg |
| Operating Ambient | 4–40 °C |
| Dimensions (W×D×H) | 215×215×180 mm |
| Weight | 2.8 kg |
| Brand | Grant Instruments |
|---|---|
| Origin | United Kingdom |
| Model | PTR-60 |
| Instrument Type | Tumble/Inversion Shaker |
| Timer Range | 1 min to 24 h |
| Oscillation Speed | 1–100 rpm |
| Rotation Amplitude | 360° continuous vertical rotation |
| Operating Mode Options | Vertical rotation, reciprocating tilt, and pulsed vibration |
| Programmable Cycles | Up to 125 loops per program |
| Vial Capacity | 26 × 15 mm microtubes |
| Platform Dimensions | 215 × 215 mm |
| Max Load | 0.5 kg |
| Input Voltage | 12 V DC |
| Operating Temperature Range | 4–40 °C |
| Display | 2×16-character LCD |
| Brand | Grant Instruments |
|---|---|
| Origin | United Kingdom |
| Model | UVT-S-AR |
| Instrument Type | Class I Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1245 × 585 × 585 mm |
| Internal Dimensions (L×W×H) | 1200 × 520 × 520 mm |
| Filter Efficiency | ≥99% |
| UV Wavelength | 254 nm |
| UV Lamp Power | 30 W (ozone-free) |
| Air Recirculation Rate | 25 m³/h |
| Timer Range | 0–24 h (digital) |
| Illumination | 15 W white LED work surface lighting |
| UV Protective View Window | UV-absorbing coated glass |
| Front Sash | 3-position height adjustment |
| Electrical Supply | 230 V |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | V-32 |
| Instrument Category | Orbital Shaker / Vortex Mixer |
| Timer Range | 1 min (manual or timed mode) |
| Oscillation Speed | 500–3000 rpm |
| Orbit Diameter | 2 mm |
| Maximum Tube Diameter | 16 mm |
| Capacity | 16 × 1.5 mL + 8 × 0.5 mL + 8 × 0.2 mL microcentrifuge tubes |
| Input Voltage | 12 V DC |
| Operating Current | 0.5 A |
| Ambient Operating Temperature | 5–40 °C |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | AS ONE Corporation |
| Product Type | Imported Instrument |
| Model No. | 3-7413-01 |
| Power Supply | AC 220 V, 50/60 Hz, Max. 75 W |
| Dimensions (H×W×D) | 445 × 425 × 420 mm |
| Net Weight | 13.5 kg |
| Microgravity Simulation Range | ≤1 × 10⁻³ G |
| Hypergravity Range | 2–3 G |
| Sample Capacity | Up to twelve T25透气培养瓶 |
| Accelerometer Integration | Yes, real-time g-force monitoring |
| Incubator-Compatible Design | Yes (fits standard CO₂ incubators) |
| Brand | GUOYI |
|---|---|
| Model | WHY-2HS |
| Power Supply | 220 V, 50 Hz |
| Total Power | 1600 W |
| Oscillation Mode | Reciprocating |
| Frequency Range | 0–300 rpm (adjustable) |
| Stroke Amplitude | 20 mm |
| Temperature Range | Ambient to 99 °C |
| Construction | Stainless steel water bath tank, cold-rolled steel housing with powder coating |
| Heating System | Bottom-mounted immersion heater |
| Control | Digital PID temperature controller with setpoint memory and overshoot suppression |
| Speed Control | Digital display with constant-speed feedback circuit |
| Compliance | Designed for GLP-compliant labs |
| Safety Features | Grounded chassis, dry-run protection, spill-resistant control panel |
| Origin | South Korea |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GX Bioreactor |
| Pricing | Upon Request |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | EZ3000 |
| Measurement Principle | Batch-type Direct Ion-Selective Electrode (ISE) Method |
| Compliance | ASTM D4658-15 |
| Detection Range | EZ3017: 1–10 mg/L |
| EZ3018 | 10–100 mg/L |
| Detection Limit | EZ3017: ≤0.5 mg/L |
| EZ3018 | ≤2.5 mg/L |
| Accuracy | ≤2% F.S. (with certified standard solutions) |
| Measurement Interval | 5 minutes (configurable) |
| Calibration | Automated two-point calibration (frequency user-configurable) |
| Validation | Automated, frequency user-configurable |
| Operating Temperature | 5–35°C ±5°C (avoid direct sunlight and rain exposure) |
| Relative Humidity | 5–95% non-condensing |
| Reagent Storage Temp. | 10–30°C |
| Sample Flow Rate | 100–300 mL/min |
| Sample Temperature | 10–30°C |
| Power Supply | 110–240 VAC, 50/60 Hz, max. 120 VA |
| Analog Output | 4–20 mA (standard 1 channel, up to 8 optional) |
| Digital Output Options | RS232, Modbus TCP/IP, Modbus RTU (RS485) |
| Sample Requirements | Max. particle size ≤100 µm |
| Certifications | CE, UL |
| Enclosure Rating | Analyzer housing: IP55 |
| PC panel | IP65 |
| Dimensions (H×W×D) | 690 × 465 × 330 mm |
| Shipping Weight | 30 kg |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | EZ4000 |
| Pricing | Available Upon Request |
| Measurement Principle | Acid–Base Titration with Standardized HCl |
| Detection Method | Photometric Endpoint Detection (610 nm or 620 nm) |
| Measured Parameters | Total Alkalinity, Free Alkalinity, Total Hardness, Calcium Hardness |
| Range (Alkalinity) | 100–5000 mg/L as CaCO₃ |
| Range (Hardness) | 100–1000 mg/L as CaCO₃ (EZ4041/EZ4044) |
| LOD (EZ4043) | ≤0.05 mg/L (via LED Immersion Probe) |
| Other Models | ≤10 mg/L |
| Cycle Time | 10–15 min per analysis |
| Operating Temperature | 5–35 °C ±5 °C (indoor, non-sunlit, non-rain-exposed) |
| Sample Temperature | 10–30 °C |
| Storage Temp (Analyzer) | −20 to +55 °C |
| (Electrodes) | −15 to +55 °C |
| Relative Humidity | 5–95% RH (non-condensing) |
| Power Supply | 110–240 VAC, 4 A, 50/60 Hz |
| Max. Power Consumption | 150 VA |
| Analog Output | 4–20 mA (1 standard channel, up to 8 optional) |
| Pneumatic Supply | Dry, oil-free air compliant with ISA-S7.0.01-1996 |
| Sample Flow Rate | 100–300 mL/min |
| Sample Requirements | Particulate max. 100 µm, suspended solids <0.1 g/L, turbidity <50 NTU |
| Certifications | CE, UL |
| Enclosure Rating | Analyzer Cabinet IP55, Front Panel PC IP65 |
| Dimensions (W×H×D) | 690 × 465 × 330 mm |
| Shipping Weight | 25 kg |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | HMA-TCU |
| Measurement Principle | High-Temperature Acid Digestion + Bathocuproine Spectrophotometry at 470 nm |
| Range | 0.1–10 mg/L Cu |
| Reagent Consumption | ≤1 month per kit |
| Waste Volume | 1.4 L/month |
| Analog Output | 2 × 4–20 mA (≤600 Ω, isolated) |
| Digital Output | RS-485 MODBUS-RTU, RS-232C |
| Relay Outputs | 2 SPDT (AC200 V/3 A, DC24 V/3 A, resistive load) |
| Operating Environment | 10–40 °C, ≤85 % RH (non-condensing) |
| Power Supply | AC 200 V ±10 %, 50 Hz |
| Power Consumption | 380 VA (max), 130 VA (avg) |
| Dimensions (H×D×W) | 900 × 255 × 600 mm |
| Weight | ~50 kg |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | NA9600 sc |
| Detection Limit | 0.01 ppb |
| Measurement Range | 0.01–10,000 ppb (non-cation-bed mode) |
| Accuracy | ±0.1 ppb (0.01–2 ppb, non-cation-bed) |
| Repeatability | <0.02 ppb or 1.5% of reading (whichever is greater) |
| Response Time | T90 ≤ 2 min (1–100 ppb) |
| Sample Temperature Range | 5–45 °C |
| Ambient Operating Temperature | 5–50 °C |
| Sample Pressure | 0.2–6 bar |
| Sample Flow Rate | 100–150 mL/min |
| Sample pH Adjustment | Diisopropylamine (DIPA), 1 L/90 days (non-cation-bed), 1 L/month (cation-bed) |
| Enclosure Rating | NEMA 4 / IP65 (with enclosure) |
| Display | 5.7-inch color LCD |
| Analog Outputs | 6 isolated 4–20 mA (max 600 Ω load) |
| Digital I/O | 6 programmable relay outputs (SPDT, 5 A, 240 VAC), 6 isolated TTL/dry-contact digital inputs |
| Communication Protocols | HART, PROFIBUS DP, Modbus RTU/TCP |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (H×W×D) | 681 × 452 × 335 mm (with enclosure) |
| Weight | 20 kg (with enclosure, no reagents) |
| Maintenance Interval | Electrolyte, activator, and calibration solutions replenished every 90 days |
| Brand | HACH |
|---|---|
| Origin | USA |
| Model | ULR CL17sc |
| Measurement Principle | DPD (N,N-Diethyl-p-phenylenediamine) Colorimetric Method |
| Measurement Range | 0.008–5 mg/L Cl₂ |
| Accuracy | ±5% or ±0.01 mg/L (whichever is greater) for 0–4 mg/L |
| Detection Limit | 0.008 mg/L Cl₂ at 25°C |
| Cycle Time | 2.5 minutes |
| Sample Flow Rate | 60–200 mL/min |
| Inlet Pressure | 0.3–5.2 bar (to Y-strainer) |
| Sample Temperature | 5–40°C |
| Operating Temperature | 5–40°C |
| Operating Humidity | 0–90% RH, non-condensing |
| IP Rating | IP66 |
| Power Supply | 12 VDC, max. 400 mA |
| Dimensions (H×W×D) | 342 × 329 × 177 mm |
| Weight | 4.1 kg |
| Light Source | LED at 510 nm, 1 cm optical path |
| Certifications | CE (EN 61326-1, CISPR 11, EN 50581), ACMA RCM, Korea KC, FCC DoC, IEC/EN 60529, ICES-003 |
| Brand | Haier Biomedical |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CJ-L37 |
| Temperature Control Range | −180 °C to +50 °C |
| Temperature Accuracy | ≤ ±0.5 °C |
| Temperature Uniformity | < ±2 °C |
| Cooling/Heating Rate Adjustment Range | 0.1–12 °C/min |
| Display Resolution | 0.1 °C |
| Liquid Nitrogen Level Monitoring | Real-time with <20% threshold alarm |
| Preloaded Programs | 6 standard protocols |
| Custom Protocol Support | Yes |
| ADRC Control Algorithm | Patented Active Disturbance Rejection Control |
| Brand | Haier Biomedical |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HYY.G002 |
| Instrument Category | Dry-Phase Thawing System |
| Data Interface | USB and RS232 |
| Display | High-Resolution LED Touchscreen |
| Data Export | CSV-formatted thawing logs with timestamp, temperature profile, and cycle ID |
| Brand | Hamilton |
|---|---|
| Origin | USA |
| Model | GFGJ-81000 |
| Capacity | 10–500 µL |
| Needle Gauge Options | 26s (OD 0.47 mm, ID 0.13 mm), 22s, 22 (OD 0.72 mm, ID 0.41 mm), 25 |
| Needle Length | 2 in (51 mm) |
| Volume per Inch (26s) | 0.26 µL/in |
| Volume per Inch (22) | 3.35 µL/in |
| Type | N-type (fixed needle, gas-tight plunger seal) |