| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HZL-X160 |
| Price | USD 2,850 (FOB Jiangsu) |
| Instrument Type | Water-Jacketed Constant-Temperature Orbital Shaker / Incubator Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–300 rpm (adjustable in 1-rpm increments) |
| Orbit Diameter | 26 mm |
| Temperature Range | 5–60 °C (ambient ≤25 °C) |
| Shelf Configuration | Single-tier platform (dual-layer capacity via stackable flask racks) |
| Chamber Volume | 160 L |
| Max Flask Load | 40 × 250 mL Erlenmeyer flasks (standard dual-layer arrangement) |
| Control System | Microprocessor-based PID controller with digital display |
| Drive Mechanism | Brushless DC motor |
| Power Supply | 220 V AC, 50 Hz |
| External Dimensions (W×D×H) | 670 × 620 × 1320 mm |
| Temperature Uniformity | ±0.3 °C across chamber (at 37 °C, steady state) |
| Temperature Stability | ±0.1 °C (setpoint deviation under load) |
| Brand | IBI Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Flow Cell |
| Price | USD 1,000 |
| Temperature Range | 0–50 °C |
| Reaction Volume per Chamber | 0–1 mL |
| Number of Flow Chambers | 3 |
| Material | Acrylic Resin |
| Sterilization Method | Gamma Irradiation |
| Brand | IBI Scientific |
|---|---|
| Origin | USA |
| Model | Low Profile Roller |
| Weight | 10.5 lbs (4.76 kg) |
| Speed Range | 2–38 rpm |
| Roller Capacity | 3 × 850 cm² culture bottles or up to 18 × 15–50 mL tubes (with optional roller kit) |
| Operating Temperature Range | 0–65 °C |
| Standard Rollers | 6 pcs (Ø28 mm × 250 mm) |
| Optional Expansion | +5 rollers for high-density small-vessel loading |
| Brand | IBI Scientific |
|---|---|
| Origin | USA |
| Model | Belly Bath |
| Instrument Type | Water Bath Incubator Shaker |
| Oscillation Speed Range | 0–100 rpm |
| Oscillation Angle Adjustment | 0–8° |
| Temperature Range | 30–75°C |
| Heating Rate | 3°C/min |
| Temperature Stability | ±0.2°C |
| Chamber Dimensions | 26.4 × 26.4 × 8.3 cm |
| Lid Material | Acrylic Transparent Cover |
| Independent Operation | Water Bath and Shaking Functions Separable |
| Shake Plate Quantity | 1 |
| Pricing | USD $5,000 |
| Brand | IBI Scientific |
|---|---|
| Origin | USA |
| Model | Belly Button |
| Instrument Type | Mini Orbital Shaker |
| Speed Range | 0–100 rpm |
| Tilt Angle Adjustment | 0–8° |
| Operating Temperature | 0–40 °C |
| Platform Size | 18 × 18 cm |
| Load Capacity | 2 kg (5 lbs) |
| Platform Material | Chemically Resistant Polymer |
| Noise Level | <45 dB(A) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Certifications | CE, RoHS |
| Compliance | Suitable for ISO 13485-aligned lab workflows, compatible with GLP documentation requirements |
| Brand | IBI Scientific |
|---|---|
| Origin | USA |
| Model | Belly Dancer |
| Instrument Type | Orbital Rocker for Staining/Destaining/Blotting |
| Speed Range | 0–100 rpm |
| Rocking Angle | 0–12° adjustable |
| Operating Temperature | 0–40 °C |
| Platform Count | 2 |
| Platform Size | 30 × 30 cm |
| Load Capacity | 9.1 kg (20 lbs) |
| Construction | Chemically Resistant Materials |
| Noise Level | Low-Noise Operation |
| Compliance | Designed for GLP-compliant lab workflows |
| Accessories | Optional single-layer, double-layer, and finger-grooved non-slip mats |
| Brand | IBI Scientific |
|---|---|
| Origin | USA |
| Model | Hi/Lo Rocker |
| Oscillation Speed Range | 0–22 rpm |
| Tilt Angle Adjustment | 2°–11° |
| Operating Temperature Range | 0–65 °C |
| Platform Dimensions | 35 × 35 cm |
| Load Capacity | 9.07 kg (20 lbs) |
| Unit Weight | 7.26 kg (16 lbs) |
| Number of Platforms | 4 |
| Temperature Control | Ambient only |
| Timer Function | Not included |
| Instrument Type | Reciprocating Rocker Shaker |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Type | Integrated Control Tower Bioreactor System |
| Reactor Volume Range | 0.5–10 L |
| Temperature Range | 0–100 °C |
| Sterilization Method | Autoclavable (121 °C, 20 min) |
| Number of Independent Gas Channels | 4 (Air, O2, N2, CO2) |
| Mass Flow Control Range | 0–2000 cc/min per channel |
| Integrated Peristaltic Pumps | 4 (Watson-Marlow 114DV) |
| Stirring Speed Range | 1–2200 rpm |
| pH Measurement Range | 0–14 pH (±0.02 pH accuracy) |
| Dissolved Oxygen Range | 0–200 %sat (±0.3 %sat accuracy) |
| Conductivity & Turbidity Sensor Interfaces | Yes |
| CO₂ Sensor Interface | Yes |
| Chaotic Mixing Mode | Yes |
| Heating Blanket Power | 250 W |
| Data Storage Capacity | 32 GB internal |
| Compliance Options | FDA 21 CFR Part 11–compliant software version available |
| Connectivity | Ethernet, USB, RS232, Wi-Fi, external pump/thermostat/single-use reactor interfaces |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Type | Integrated Control Tower Fermenter System |
| Vessel Capacity | 0.5–10 L |
| Aeration | Four Independent Mass Flow Controlled Gas Lines (Air, O2, N2, CO₂) |
| pH Control Range | 0–14 pH |
| Accuracy | ±0.02 pH |
| Dissolved Oxygen (DO) Control Range | 0–200 % saturation |
| Accuracy | ±0.3 % sat |
| Temperature Control Range | 0–100 °C |
| Accuracy | ±0.2 °C |
| Stirring | Chaotic Mixing Mode + Standard Profile/Cascade Modes |
| Speed Range | 1–2200 rpm |
| Reversibility | Yes |
| Peristaltic Pumps | 4 × Watson-Marlow 114DV heads (Acid, Base, Antifoam, Feed) |
| Flow Range | 1–270 mL/min |
| Data Management | 32 GB internal storage, Ethernet, USB, RS232, Wi-Fi, FDA 21 CFR Part 11-compliant software option available |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Benchtop Bioreactor with Integrated Control Tower |
| Vessel Capacity | 0.5–10 L |
| Gas Supply | Four independent mass flow-controlled gas lines (Air, O2, N2, CO2) |
| pH Control Range | 0–14 pH |
| Accuracy | ±0.02 pH |
| Dissolved Oxygen (DO) Control Range | 0–200% saturation |
| Accuracy | ±0.3% sat |
| Temperature Control Range | 0–100 °C |
| Accuracy | ±0.2 °C |
| Stirring | Chaotic Mixing mode + conventional profile/Cascade control |
| Speed range | 1–2200 rpm |
| Reversibility | Yes |
| Sensors Supported | pH, DO, temperature, level, foam, CO₂, conductivity, turbidity |
| Peristaltic Pumps | 4 × Watson-Marlow 114DV heads (acid, base, antifoam, feed) |
| Flow range | 1–270 mL/min |
| Software | Touch-enabled tablet interface (10.4″), real-time data logging, calibration management, FDA 21 CFR Part 11-compliant version optional |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Connectivity | Ethernet, USB, RS232, Wi-Fi, external thermostat & pump interfaces |
| Enclosure Rating | IP20 |
| Power | 100–240 V AC, 50/60 Hz |
| Max. input power | 1100 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HABITAT |
| Dimensions (W×H×D) | 224 × 624 × 405 mm |
| Stirring Speed Range | 1–2200 rpm |
| Peristaltic Pump Heads | 4 (acid, base, antifoam, level) |
| Pump Flow Rate | 1–270 mL/min |
| Gas Flow Rate | 0–2 L/min (CELL/CCT) |
| Mass Flow Controllers (MFCs) | 4 (Air, O₂, N₂, CO₂) |
| Controlled Parameters | Agitation, Aeration, Liquid Feed, Off-gas Analysis, Temperature, pH, Dissolved Oxygen (DO), Foam, Level, Conductivity, CO₂, Turbidity, Light |
| Interfaces | USB, RS-232, Ethernet, SU Connection, Chiller Interface, External Pump Control, 4–20 mA Analog I/O |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Model | HABITAT Photo Ferment CCT |
| Vessel Volume | 0.5–10 L |
| Gas Supply | Four independent mass flow-controlled gas lines (N₂, O₂, air, CO₂) |
| pH Control Range | 0–14 pH |
| Accuracy | ±0.02 pH |
| Dissolved Oxygen (DO) Control Range | 0–200% saturation |
| Accuracy | ±0.3% sat |
| Temperature Control Range | 0–100 °C |
| Accuracy | ±0.2 °C |
| Stirring Speed | 1–2200 rpm |
| Speed Deviation | ±2% (≥100 rpm), ±5 rpm (<100 rpm) |
| LED Illumination | Adjustable intensity & timing for circadian simulation |
| Chaotic Mixing Mode | Enabled |
| Integrated Peristaltic Pumps | 4 Watson-Marlow 114DV heads (acid, base, antifoam, feed) |
| Data Storage | 32 GB internal |
| Compliance Options | FDA 21 CFR Part 11–compliant software version available |
| Interfaces | Ethernet, USB, RS232, external pump/thermostat/single-use reactor ports |
| Protection Rating | IP20 |
| Power Input | 100–240 V, 50/60 Hz |
| Max. Power Consumption | 1100 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | HABITAT photo ferment |
| Vessel Volume | 0.5–10 L |
| Aeration System | Integrated 4-channel mass flow controllers (N₂, O₂, air, CO₂) |
| pH Control | Range 0–14, Accuracy ±0.02 |
| Dissolved Oxygen (DO) Control | Range 0–200% saturation, Accuracy ±0.03% |
| Temperature Control | Range 0–100 °C, Accuracy ±0.2 °C |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HS 260 basic |
| Instrument Type | Reciprocal Shaker |
| Timer Range | 5–50 min |
| Oscillation Frequency | 0–300 rpm |
| Stroke Length | 20 mm |
| Temperature Control | None |
| Platform Quantity | 1 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HS 260 basic |
| Timer Range | 5–50 min |
| Oscillation Frequency | 0–300 rpm |
| Stroke Length | 20 mm |
| Platform Quantity | 1 |
| Max Load Capacity (incl. clamp) | 7.5 kg |
| Input Power | 45 W |
| Dimensions (W×H×D) | 360 × 420 × 100 mm |
| Weight | 8.5 kg |
| Ambient Temperature Range | 5–50 °C |
| Relative Humidity Limit | ≤80 % |
| Protection Class | IP21 |
| Voltage | 220–240 V / 100–120 V, 50/60 Hz |
| Motor Output Power | 10 W |
| Minimum Adjustable Speed | 20 rpm |
| Display | LED for speed and timer |
| Operation Modes | Timed or continuous |
| Platform Type | Flat reciprocating platform |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HS 260 control NOL |
| Timer Range | 1–599 min |
| Oscillation Frequency | 10–300 rpm |
| Stroke Diameter | 20 mm |
| Temperature Range | 5–50 °C |
| Max Load Capacity (incl. clamp) | 7.5 kg |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Input Power | 45 W |
| Protection Rating | IP21 |
| Interface | RS232, Analog Output |
| Dimensions (W×H×D) | 360 × 100 × 420 mm |
| Weight | 8.8 kg |
| Ambient Operating Conditions | 5–50 °C, ≤80% RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HS 260 control |
| Instrument Type | Reciprocal Shaker |
| Timer Range | 1–599 min |
| Oscillation Frequency | 10–300 rpm |
| Stroke Length | 20 mm |
| Temperature Control | None |
| Platform Quantity | 1 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HS 260 control |
| Timer Range | 1–599 min |
| Oscillation Frequency | 10–300 rpm |
| Stroke Length | 20 mm |
| Temperature Range | 5–50 °C |
| Platform Quantity | 1 |
| Max Load Capacity | 7.5 kg |
| Display | LCD (speed & timer) |
| Control Interface | RS-232, analog output |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Input Power | 45 W |
| Protection Rating | IP21 |
| Dimensions (W×H×D) | 360 × 100 × 420 mm |
| Weight | 8.8 kg |
| Ambient Operating Conditions | 5–50 °C, ≤80 % RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | HS 260 control |
| Price | Upon Request |
| Motion Type | Reciprocal |
| Orbit Diameter | 20 mm |
| Max Load Capacity (incl. clamp) | 7.5 kg |
| Motor Input Power | 45 W |
| Motor Output Power | 10 W |
| Duty Cycle | 100 % |
| Speed Range | 10–300 rpm |
| Speed Display | LCD |
| Timer | Yes |
| Timer Display | LCD |
| Timer Setting Range | 1–599 min |
| Operation Modes | Timed & Continuous |
| Benchtop Vibration Damping | Yes |
| Dimensions (W×H×D) | 360 × 100 × 420 mm |
| Weight | 8.8 kg |
| Ambient Temperature Range | 5–50 °C |
| Relative Humidity Limit | 80 % |
| Ingress Protection | IP21 (DIN EN 60529) |
| RS232 Interface | Yes |
| Analog Output | Yes |
| Voltage | 220–240 V / 100–120 V |
| Frequency | 50/60 Hz |
| Device Input Power | 45 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HS 501 Digital |
| Drive Type | Reciprocal & Circular Orbital |
| Orbit Diameter | 30 mm |
| Speed Range | 0–300 rpm |
| Speed Display | LED Digital |
| Load Capacity (incl. clamps) | 15 kg |
| Timer Range | 1–56 min |
| Timer Display | Analog Scale |
| Operating Mode | Timed or Continuous |
| Input Power | 74 W |
| Motor Input Power | 70 W |
| Motor Output Power | 19 W |
| Duty Cycle | 100 % continuous operation |
| Ambient Temperature Range | 5–50 °C |
| Relative Humidity Limit | ≤80 % |
| Protection Class | IP21 (DIN EN 60529) |
| Voltage | 230 / 115 / 100 V |
| Frequency | 50/60 Hz |
| Dimensions (W × H × D) | 505 × 120 × 585 mm |
| Weight | 26 kg |
| Clamp Assembly | Not included — ordered separately |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HS 501 digital |
| Instrument Type | Reciprocating Shaker |
| Timer Range | 1–55 min |
| Oscillation Speed | 0–300 rpm |
| Stroke Amplitude | 30 mm |
| Number of Platforms | 1 |
| Max Load Capacity (including clamps) | 15 kg |
| Power Supply | 230 / 115 / 100 V, 50/60 Hz |
| Input Power | 74 W |
| Output Power | 19 W |
| Protection Rating | IP21 |
| Operating Temperature Range | 5–50 °C |
| Relative Humidity Limit | ≤80 % RH |
| Dimensions (W × H × D) | 505 × 120 × 585 mm |
| Weight | 26 kg |
| Interface | RS232, USB |
| Continuous Duty Cycle | 100 % |
| Display | LED, 7-segment digital speed & timer readout |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HS260 |
| Oscillation Mode | Reciprocal (Linear) |
| Stroke Length | 20 mm |
| Platform Quantity | 1 |
| Max Load Capacity | 7.5 kg |
| Speed Range | 20–300 rpm |
| Timer Options | Continuous (∞) or 5–50 min |
| Speed & Time Display | LED |
| Power Input/Output | 45 W / 10 W |
| Dimensions (W×D×H) | 360 × 420 × 98 mm |
| Net Weight | 8.5 kg |
| Operating Ambient Temperature | 5–50 °C |
| Max Relative Humidity | 80 % RH |
| Clamp Fixtures | Not included — ordered separately |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HS260 Basic |
| Timer Range | 5–50 min |
| Oscillation Frequency | 0–300 rpm |
| Stroke Length | 20 mm |
| Platform Quantity | 1 |
| Max Load Capacity (incl. clamp) | 7.5 kg |
| Motor Input Power | 45 W |
| Operating Temperature Range | 5–50 °C |
| Relative Humidity Limit | 80 % |
| Protection Class | IP21 |
| Voltage | 220–240 V / 100–120 V |
| Frequency | 50/60 Hz |
| Dimensions (W×H×D) | 360 × 100 × 420 mm |
| Weight | 8.5 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Hula Dancer basic |
| Instrument Type | Orbital Mixer/Shaker |
| Speed Range | Fixed at 2800 rpm |
| Orbit Diameter | 4.5 mm |
| Max Load Capacity (incl. clamp) | 0.1 kg |
| Input Power | 9.5 W |
| Output Power | 5 W |
| Continuous Operation | 100% duty cycle |
| Momentary Activation (Touch-Start) | Yes |
| Dimensions (W × H × D) | 123 × 42 × 123 mm |
| Weight | 0.7 kg |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % RH |
| Ingress Protection | IP42 per DIN EN 60529 |
| Voltage | 100–240 V AC |
| Frequency | 50/60 Hz |
| Standby Power Consumption | 0.7 W |
| Timer | None |
| Heating/Cooling Function | None |
| Platform Quantity | Single fixed platform |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | Hula Dancer basic |
| Instrument Type | Orbital Shaker |
| Oscillation Mode | Circular |
| Orbit Diameter | 4.5 mm |
| Speed Range | Fixed at 2800 rpm |
| Max Load Capacity (including clamps) | 0.1 kg |
| Operating Temperature Range | 5–40 °C |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % |
| Protection Rating | IP42 (per DIN EN 60529) |
| Input Voltage | 100–240 V AC |
| Frequency | 50/60 Hz |
| Motor Input Power | 9.5 W |
| Motor Output Power | 5 W |
| Standby Power Consumption | 0.7 W |
| Dimensions (W × H × D) | 123 × 42 × 123 mm |
| Weight | 0.7 kg |
| Continuous Operation | 100 % duty cycle |
| Momentary Start Function | Yes |
| Timer Display | None |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Model | Hula Dancer digital |
| Instrument Type | Orbital Shaker for Sample Mixing |
| Speed Range | 1200–2800 rpm |
| Orbit Diameter | 4.5 mm |
| Max Load Capacity (incl. clamp) | 0.1 kg |
| Input Power | 9.5 W |
| Output Power | 5 W |
| Continuous Operation | 100% duty cycle |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80% RH |
| Protection Class | IP42 (DIN EN 60529) |
| Voltage | 100–240 V AC |
| Frequency | 50/60 Hz |
| Standby Power Consumption | 0.8 W |
| Dimensions (W × H × D) | 123 × 42 × 123 mm |
| Weight | 0.7 kg |
| Momentary Activation Function | Yes |
| Timer | Not integrated |
| Speed Display | Not equipped |
| Heating/Cooling | None |
| Platform Configuration | Single fixed orbital platform |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | Hula Dancer digital |
| Instrument Type | Orbital Shaker |
| Oscillation Mode | Circular |
| Orbit Diameter | 4.5 mm |
| Speed Range | 1200–2800 rpm |
| Speed Resolution | Fixed or Adjustable (No Digital Display) |
| Load Capacity (incl. Clamp) | 0.1 kg |
| Temperature Operating Range | 5–40 °C |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % RH |
| Protection Class | IP42 (per DIN EN 60529) |
| Input Voltage | 100–240 V AC |
| Frequency | 50/60 Hz |
| Motor Input Power | 9.5 W |
| Motor Output Power | 5 W |
| Standby Power Consumption | 0.8 W |
| Continuous Operation Rated | 100 % |
| Dimensions (W × H × D) | 123 × 42 × 123 mm |
| Weight | 0.7 kg |
| Momentary Start Function | Yes |
| Timer | Not integrated |
| Speed Display | None |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Model | KS 130 basic |
| Timer Range | 5–50 min |
| Oscillation Speed | 0–800 rpm |
| Orbit Diameter | 4 mm |
| Maximum Load Capacity (incl. clamp) | 2.0 kg |
| Power Input | 45 W |
| Motor Output | 10 W |
| Operating Mode | Timed or Continuous |
| Display | LED for speed and time |
| Protection Rating | IP21 |
| Dimensions (W × H × D) | 270 × 98 × 316 mm |
| Weight | 8.8 kg |
| Ambient Temperature Range | 5–50 °C |
| Relative Humidity Limit | ≤80 % |
| Voltage | 220–240 V / 100–120 V |
| Frequency | 50/60 Hz |
| Compliance | DIN EN 60529 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Model | KS 130 control |
| Timing Range | 1–599 min |
| Oscillation Speed | 0–800 rpm |
| Orbit Diameter | 4 mm |
| Max Load Capacity (incl. clamp) | 2.0 kg |
| Display | LCD for speed and timer |
| Operation Modes | Timer mode / Continuous mode |
| Interface | RS-232, Analog Output |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Input Power | 45 W |
| Protection Rating | IP21 |
| Dimensions (W×H×D) | 270 × 98 × 316 mm |
| Weight | 9.8 kg |
| Ambient Operating Conditions | 5–50 °C, ≤80% RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | KS 260 basic |
| Instrument Type | Orbital Shaker |
| Timer Range | 5–50 min |
| Oscillation Speed | 0–500 rpm |
| Orbit Diameter | 10 mm |
| Number of Platforms | 1 |
| Max Load Capacity (incl. clamp) | 7.5 kg |
| Input Power | 45 W |
| Operating Temperature Range | 5–50 °C |
| Relative Humidity Limit | ≤80 % |
| Protection Class | IP21 |
| Voltage | 220–240 V / 100–120 V |
| Frequency | 50/60 Hz |
| Analog Output | Yes |
| Continuous Operation | Supported |
| Dimensions (W×H×D) | 360 × 98 × 420 mm |
| Weight | 8.5 kg |