| Brand | ATS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | AE-o |
| Pricing | Upon Request |
| Carrier Type | Lipid Nanoparticle (LNP) |
| Brand | ATS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AE001 |
| Price Range | USD 4,200 – 11,200 (FOB) |
| Vesicle Type | Liposomes |
| Sample Volume | 2–800 mL |
| Operating Pressure | 0–1000 psi |
| Final Particle Size | 50–1000 nm |
| Filter Diameter Options | 25 mm / 47 mm / 90 mm |
| Temperature Control Range | 5–80 °C |
| Wetted Materials | 316L Stainless Steel, FDA-Certified Elastomers (O-rings, gaskets), Electropolished Surfaces (Ra ≤ 1.5 µm) |
| Compliance | GMP-Compatible Design, Cleanroom-Ready (ISO Class 5–7) |
| Brand | ATS |
|---|---|
| Origin | Canada |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AH-1500 |
| Instrument Type | High-Pressure Cell Disruptor |
| Max Operating Pressure | 1500 bar (22,500 psi) |
| Optional Overpressure Capability | 1800 bar (27,000 psi) |
| Flow Rate | 15 L/h |
| Minimum Sample Volume | 25 mL |
| In-Line Cooling System | Integrated, maintains sample temperature < 20 °C |
| Contact Wetted Materials | ASTM A240 316L stainless steel |
| Motor Power | 2.2 kW, 380 V / 50 Hz |
| Weight | 110 kg |
| Compliance | CE-marked, GMP-compliant design |
| Particle Size Output | < 100 nm (after single-pass homogenization) |
| Disruption Efficiency | >95% for *E. coli*, >90% for yeast |
| Brand | ATS |
|---|---|
| Origin | Canada |
| Model | AH-1500 |
| Instrument Type | High-Pressure Cell Disruptor |
| Operating Pressure | 1500 bar (22,500 psi), up to 1800 bar (27,000 psi) |
| Motor Power | 2.2 kW, 380 V / 50 Hz |
| Throughput | 15 L/h |
| Minimum Sample Volume | 25 mL |
| In-Line Cooling System | Integrated, maintains sample temperature < 20 °C |
| Wetted Materials | 316L stainless steel |
| Compliance | CE-certified, GMP-compliant design |
| Particle Size Reduction | < 100 nm |
| Cell Disruption Efficiency | >95% for E. coli, >90% for yeast |
| Weight | 110 kg |
| Brand | ATS |
|---|---|
| Origin | Canada |
| Manufacturer | ATS (Producer) |
| Product Type | Imported |
| Model | NF-1 |
| Sample Volume | 0.1–1 mL |
| Membrane Pore Sizes Available | 50, 100, 200, 400, 800, 1000 nm |
| Included Components | 2 × 1000 µL glass syringes, 1 extrusion module, 20 membranes (200 nm & 400 nm standard) |
| Temperature Compatibility | Water-bath compatible (ambient to 60 °C) |
| Residual Volume | ≤1 µL per cycle |
| Weight | <2 kg |
| Optional Upgrades | Mechanical stabilization base, nitrogen-driven pressure control system with adjustable pressure (0.1–6 bar), programmable cycle count and dwell time |
| Brand | ATS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | LF-1 Pneumatic Stand |
| Carrier Type | Liposomes |
| Construction Material | Anodized Aluminum Alloy |
| Actuation Method | Pneumatically Driven Linear Force Application |
| Compatibility | Designed exclusively for ATS LF-1 Liposome Extrusion Devices |
| Brand | ATS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NANOJ EX5 |
| Price Range | USD 7,000 – 140,000 (FOB) |
| Compatible Vesicle Type | Liposomes |
| Standard Filter Pore Size | 100 nm |
| Optional Pore Sizes | 50, 200, 400, 800 nm |
| Brand | ATS |
|---|---|
| Origin | Canada |
| Manufacturer | ATS (Original Equipment Manufacturer) |
| Product Type | Imported |
| Model | H10 |
| Instrument Category | High-Shear Cell Disruptor |
| Motor | German-sourced, industrial-grade |
| Bearing | SKF |
| Power | 0.5 kW |
| Voltage | 220 V, 50 Hz |
| Speed Range | 10,000–28,000 rpm (7-step infinitely variable control) |
| Tip Linear Velocity | up to 28.5 m/s |
| Net Weight | 9 kg |
| Batch Volume | 100–5,000 mL (tested in water |
| Protection Rating | IP55 |
| Insulation Class | F |
| Explosion-Proof | No |
| Rotor/Stator Material | Stainless Steel SUS304 or optional SUS316L |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | AutoChem B861 |
| Price Range | USD 150–15,000,000 (FOB) |
| Detection Principle | Post-Dispensing Spectrophotometry with 16-Wavelength Optical System |
| Sample Throughput | Up to 800 tests/hour (typical configuration) |
| HbA1c Capability | Whole Blood Direct Measurement |
| Mechanical Durability | >5,000,000 cycles validated under continuous-load fatigue testing |
| Key Components | Imported precision optical modules, high-accuracy peristaltic pumps, and temperature-stabilized reaction cuvettes |
| Brand | Autoscience |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SRJ-20A |
| Input Signal Range | 10 mV / 100 mV / 1 V |
| Valve Delay Time | 10–90 s |
| Maximum Flow Rate | 50 mL/min (through 1/16" tubing) |
| Display | Dual-color (red/green) LCD |
| Zero Adjustment | Auto-zero tracking baseline drift |
| Power Supply | 13.5 V / 500 mA |
| Dimensions (L×W×H) | 14.2 × 18.5 × 6.28 cm |
| Weight | 1.0 kg |
| Brand | Autosense |
|---|---|
| Membrane Materials | Mixed Cellulose Ester (MCE) & Polyvinylidene Fluoride (PVDF) |
| Available Diameters | 13 mm, 25 mm, 50 mm |
| Pore Sizes | 0.18 µm, 0.22 µm, 0.45 µm, 0.8 µm, 1.2 µm |
| Pack Size | 100 units per pack |
| Compliance | ISO 9001-manufactured |
| Brand | Autosense |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FB-04T |
| Capacity | 30 mL |
| Filter Diameter | 25 mm |
| Components | Filter Funnel (30 mL), Central Filter Holder, Vacuum Filtration Flask, Aluminum Clamp Set |
| Price Range | USD 140 – 1,400 |
| Brand | Autosience |
|---|---|
| Model | AL-01 |
| Construction | Borosilicate glass filtration assembly (FB-10T, 1000 mL capacity) with sintered glass frit (porosity: 10–16 µm) |
| Vacuum source | AP-01P oil-free diaphragm vacuum pump (ultimate vacuum: ≤70 mbar, flow rate: 25 L/min) |
| Optional upgrade | FB-20T 2000 mL filtration kit |
| Filtration volume per cycle | 300 mL (funnel capacity) |
| Compatibility | Standard 29/32 and 45/50 joint sizes for interchangeability with major international brands (e.g., Whatman, Millipore, Thermo Fisher) |
| Regulatory alignment | Designed for GLP-compliant lab environments |
| Brand | AVESTIN |
|---|---|
| Origin | Canada |
| Manufacturer | Avestin Inc., Ottawa, Canada |
| Model | EmulsiFlex-C50 |
| Max Operating Pressure | 30,000 psi (207 MPa) |
| Flow Rate | 15–50 L/h |
| Minimum Sample Volume | 25 mL |
| Drive Type | Pneumatic Dual-Piston |
| Safety | Auto-circuit cutoff with 20% transient overpressure tolerance |
| Construction Material | ASTM-certified 316L stainless steel |
| Sterilization | Direct steam-in-place (SIP), O-ring-free fluid path |
| Compliance | FDA 21 CFR Part 11-ready architecture, GMP-compliant design |
| Optional Accessories | Extrusion filter, heat exchanger |
| Instrument Category | High-Pressure Cell Disruptor |
| Brand | Avestin |
|---|---|
| Origin | Canada |
| Manufacturer | Avestin Inc., Ottawa, Canada |
| Model | EmulsiFlex-C55 |
| Pressure Range | 0–30,000 psi (0–207 MPa) |
| Flow Rate | 15–50 L/h |
| Minimum Sample Volume | 7 mL |
| Drive Type | Pneumatic Dual-Piston |
| Compliance | GMP, FDA 21 CFR Part 11–ready architecture, ASME BPE–compatible materials |
| Construction Material | Electropolished 316L stainless steel |
| Sterilization | SIP/CIP-capable, O-ring–free fluid path |
| Safety | Auto-cutoff circuit protection, transient overpressure tolerance up to 20% |
| Brand | Avestin |
|---|---|
| Origin | Canada |
| Manufacturer | Avestin Inc., Ottawa, ON |
| Model | EmulsiFlex-D20 |
| Operating Pressure | 35,000 psi (2,413 bar) / Max Continuous: 30,000 psi (2,070 bar) |
| Flow Rate | 20 L/h |
| Minimum Sample Volume | 50 mL |
| Sample Hold-up Volume | <1 mL |
| Drive Type | Electric Single-Plunger Pump |
| Dimensions (W×D×H) | 730 × 600 × 640 mm |
| Weight | 120 kg |
| Power Supply | 3-phase, 50/60 Hz, 230/400 V |
| Construction Material | ASTM A240 316L stainless steel + ceramic wear components |
| Sterilization | Direct steam-in-place (SIP) compatible |
| Compliance | GMP-compliant design, FDA 21 CFR Part 11–ready software architecture, USP <1043> and ISO 22442-1 applicable for bioprocess equipment qualification |
| Brand | AVESTIN |
|---|---|
| Origin | Canada |
| Model | LF-50 |
| Maximum Sample Volume | 50 mL per run |
| Operating Pressure | Up to 600 psi (41 bar) |
| Membrane Stack Configuration | Up to 3 polycarbonate membranes with support liners |
| Temperature Control | Jacketed stainless steel sample chamber compatible with external thermostatic circulators |
| Compliance | Designed for GMP-compliant processing and cleanability |
| Brand | AVESTIN |
|---|---|
| Origin | Canada |
| Model | LF1 |
| Sample Volume | 0.1–1 mL |
| Membrane Pore Sizes | 50, 100, 200, 400, 800, 1000 nm |
| Operating Principle | Manual pressure-driven extrusion through polycarbonate track-etched membranes |
| Weight | <2 kg |
| Temperature Compatibility | Compatible with water bath (ambient to 60 °C) |
| Includes | Two 1 mL glass syringes, one extrusion module, fifty 100 nm membranes |
| Optional Accessories | Stabilizing base clamp, nitrogen-driven automated extrusion system |
| Brand | Azenta (formerly Brooks Life Sciences) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Biobanking Infrastructure Systems |
| Temperature Ranges | RT to –20°C, –80°C, –150°C (Vario), –196°C (Cryo) |
| Automation Level | Fully Automated Sample Storage & Retrieval |
| Compliance | Designed for GLP/GMP-aligned biorepository operations, 21 CFR Part 11–ready software architecture |
| Dimensions (BioStore II –80°C, Quad-height) | 12.77 m × 2.78 m × 3.04 m |
| Dimensions (BioStore III Cryo –196°C, Ultra-high capacity) | 18.17 m × 4.78 m × 3.24 m |
| LN₂ Consumption (BioStore III Cryo, static) | ~9.5–12.5 L/day |
| Temperature Hold Time (fail-safe) | ≥21 days at –190°C after power loss |
| Brand | Azenta Brooks FluidX |
|---|---|
| Origin | Japan |
| Model | 66-62325-Y6 |
| Volume Options | 0.3 mL, 0.5 mL, 0.7 mL, 0.9 mL (internal/external thread), 2.2 mL (external thread) |
| Format | 96-well SBS-compliant or 24-well for tissue tubes |
| Material | Virgin polypropylene (PP) |
| Max Operating Temperature | −196 °C (liquid nitrogen vapor phase only) |
| Cap Types | Automation-friendly screw caps with silicone O-rings or TPE septa |
| Tube Base | Permanently laser-etched 2D QR code + human-readable numeric ID |
| Rack Compatibility | LowBase/HighBase SBS racks, TwistLock/TubeLock/LidLock-enabled PC cryo-racks (14×14, 7×7) |
| Compliance | ASTM F2668, ISO 20365, USP <665>, GLP/GMP traceability ready |
| Brand | Azenta Brooks FluidX |
|---|---|
| Origin | Japan |
| Model | 66-9302 |
| Capacity | 7.6 mL (24-well format), 1.9 mL / 1.5 mL / 1.0 mL / 0.5 mL / 0.26 mL (48/96-well formats) |
| Material | Virgin polypropylene (PP) |
| Sterilization | Gamma-irradiated (optional) |
| Temperature Range | -196 °C to +121 °C |
| Thread Type | External thread |
| Max. Centrifugation | 20,000 × g |
| Compliance | ISO 15189, ISO/IEC 17025, FDA 21 CFR Part 11 (software-integrated workflows), GLP/GMP-ready |
| Brand | AZENTA |
|---|---|
| Country of Origin | Germany |
| Model | Barkey Plasmatherm |
| Power Supply | 230 V / 50 Hz |
| Temperature Range | 25–45 °C (standard mode) |
| Dimensions (L×W×H) | 60 × 34 × 32 cm |
| Net Weight | 18 kg |
| Max. Chamber Volume | 9 L |
| Certifications | CE 0120, China NMPA Import Registration No. 20162451979, ISO 9001, ISO 13485 |
| Compliance | FDA 21 CFR Part 606.122 (Blood & Blood Components), GLP/GMP-ready |
| Interface Options | RS232, Ethernet (for TCP Logging Tool), Barcode Reader, Log Printer |
| Safety Features | Dual independent thermal fuses, liquid leakage sensor, audible/visual end-of-cycle alert, self-test at power-on |
| Heating Technology | Dry-contact conductive heating (no water bath, no direct fluid contact) |
| Brand | Barkey |
|---|---|
| Origin | United Kingdom |
| Model | Barkey Plasmatherm |
| Instrument Type | Dry-phase (non-contact, closed-loop thermal transfer) thawing system |
| Regulatory Classification | Class II medical device per MDR 2017/745 (EU), compliant with ISO 23500-1:2023 for blood component warming |
| Software Compliance | Audit-trail enabled, 21 CFR Part 11–ready data logging |
| Certification | CE-marked, UKCA-certified, GMP-aligned design |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | BioLector XT |
| Vessel Dimensions | 95 × 514 × 541 mm |
| Aeration System | Innovative Gassing Lid with Precise Gas Mixing |
| pH Control Range | ~4.0–6.0 or ~5.0–7.5 (calibration-dependent) |
| Dissolved Oxygen (DO) Control Range | 0–100% air saturation (via O₂/N₂/CO₂ blending) |
| Temperature Control Range | −8 °C to +50 °C |
| Working Volume per Well | 800–2400 µL |
| Plate Format | ANSI/SLAS-compliant 48-well microtiter plate (MTP) |
| Sensor Technology | Non-invasive optical measurement (scattered light, fluorescence, absorbance, pH & DO via immobilized optodes) |
| Optional Modules | Microfluidic Feeding Module, Humidification Unit, Multi-gas Blending Controller |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Vi-CELL MetaFLEX |
| Pricing | Available Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DZD-16 |
| Instrument Type | Inversion Shaker |
| Timer Range | 1 s – 99 h 99 min |
| Oscillation Frequency | Up to 300 cycles/min |
| Inversion Angle | 360° continuous rotation |
| Temperature Control | Ambient only |
| Tray Capacity | 16 sample positions |
| Sample Volumes | 250 mL × 8 or 500 mL × 8 |
| Rotation Direction | Bidirectional (forward/reverse) |
| Speed Control | 0–200 rpm adjustable |
| Extraction Efficiency | >95% |
| Safety Design | Sealed extraction vessels, fume containment, ventilator-compatible footprint |
| Brand | Beifen Sanpu |
|---|---|
| Model | SK-1 |
| Type | Vortex Mixer |
| Power Supply | 220 V ±10%, 50 Hz |
| Power Consumption | 40 W |
| Operating Mode | Orbital (Circular) Motion |
| Oscillation Frequency | 3000 rpm |
| Amplitude | 5 mm |
| Timer Range | 5–120 s |
| Tray Configuration | Single Platform |
| Sample Holder Compatibility | Test Tubes, Colorimetric Tubes, Small Erlenmeyer Flasks (≤100 mL) |
| Origin | Hebei, China |
| Manufacturer Status | Direct Manufacturer |
| Regulatory Classification | Domestic Instrument for Academic & General Laboratory Use |
| Price Range | USD 140–700 (FOB) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Orbital Water Bath Incubator Shaker |
| Timer Range | 5–120 min |
| Oscillation Frequency | 0–300 rpm |
| Oscillation Amplitude | 20 mm |
| Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±0.5 °C |
| Heating Power | 1880 W |
| Tray Dimensions | 39 × 29 cm |
| Overall Dimensions | 700 × 550 × 480 mm |
| Power Supply | AC 220 V, 50 Hz |
| Chamber Material | Stainless Steel (304) |
| Drive Mechanism | Belt-driven orbital motion with mechanical speed regulation |
| Timer Function | Mechanical dial timer with “continuous” position |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Water Bath Incubator Shaker |
| Model | THZ-82(A) |
| Timing Range | 0–120 min |
| Oscillation Frequency | Adjustable, 0–300 rpm |
| Oscillation Amplitude | 20 mm |
| Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±0.5 °C |
| Oscillation Mode | Orbital (standard for THZ-82 series) |
| Tray Quantity | 1 |
| Power Supply | 220 V, 50 Hz |
| Heating Power | 1800 W |
| Water Bath Chamber Dimensions | 490 × 390 × 170 mm (L×W×H) |
| Overall Dimensions | 700 × 550 × 490 mm (L×W×H) |
| Construction | Stainless Steel Interior |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TY-80A/TS-80 |
| Instrument Type | Orbital Shaker |
| Timer Range | 0–120 min |
| Oscillation Frequency | 0–80 rpm (infinitely adjustable) |
| Oscillation Amplitude | 10 mm |
| Platform Dimensions | 280 × 220 mm |
| Operating Mode | Continuous |
| Power Consumption | 20 W |
| Voltage/Frequency | 220 V, 50 Hz |
| Platform Quantity | 1 |