- All
- Favorite
- Popular
- Most rated
| Brand | Boante |
|---|---|
| Model | BAT260/360/500/650/850/1050/1600/2500-GZ |
| Temperature Range | 5–50 °C |
| Temperature Uniformity | ±1 °C (at same shelf level) |
| Humidity Range | Not applicable (GZ series is humidity-free) |
| 光照 Intensity | 0–600 μmol/m²/s (0–100% continuously adjustable, measured at 100 mm from LED source) |
| Light Source | Top-mounted horizontal LED array with independent per-shelf dimming control |
| Capacity | 260–2500 L |
| Control System | BAT200PG intelligent controller with 7-inch color touchscreen, 24-segment programmable cycle (real-time Beijing time), adaptive three-stage fuzzy logic PID algorithm |
| Data Logging | Internal storage for ≥5 years of timestamped temperature and operational data |
| Safety Protections | Compressor overheat, fan overheat, overtemperature, high-pressure cutoff, overload protection, independent mechanical overtemperature limiter |
| Certifications & Compliance | Designed to support GLP-compliant workflows |
| Brand | Boante |
|---|---|
| Model | BAT600-ZDSS |
| Origin | Hubei, China |
| Type | Custom-Size Artificial Climate Incubator for Plant Phenotyping and Gene Function Studies |
| Temperature Range | 5–45 °C (Control Accuracy ≤ ±0.2 °C |
| Humidity Range | 30–95 % RH (Control Accuracy ≤ ±5 % RH) |
| Lighting | Top-mounted LED array with full-spectrum white (350–800 nm), 660 nm red, 470 nm blue, and 720 nm far-red |
| spectral ratio configurable (e.g., R | B:W:FR = 5:2:2:1) |
| Control System | 15.6″ industrial touchscreen + PLC-based logic controller with embedded Chinese OS |
| Environmental Exchange | Programmable fresh-air intake via energy-recovery heat exchanger |
| Safety & Compliance | Over-temperature cut-off, compressor suction pressure regulation (0–480 psig), PTC auxiliary heating, IoT-enabled remote monitoring and control (edge-computed, no client software required), real-time curve logging (365-day history), GLP-ready audit trail capability (timestamped parameter changes, user logins, alarm events) |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Custom-Engineered (Non-Standard) |
| Quotation | Upon Request |
| Temperature Range | 10–45°C (with lighting), 0–45°C (without lighting) |
| Temperature Uniformity | ±1.0°C (standard), ±2.0°C (extended range) |
| Humidity Range | 40–80% RH (with lighting), 40–85% RH (without lighting) |
| Humidity Uniformity | ±3–5% RH |
| Photosynthetic Photon Flux Density (PPFD) Options | 0–200, 0–600, 0–800, or 0–1200 µmol/m²/s (measured at 150 mm from source) |
| Fresh Air Exchange | ≥300 m³/h, ≥10 air changes/h |
| Chamber Volume & Dimensions | Fully Customizable |
| Insulation | Polyurethane sandwich panels (50/75/100 mm thick), A1-class fire-rated core, steel facing ≥0.426 mm, density ≥120 kg/m³ |
| Lighting Spectrum | Continuous 380–780 nm (including far-red), PAR-optimized LED array |
| Control Interface | Color TFT touchscreen PLC (5″–15.6″ options), embedded Boante-developed firmware on MOXA/Kunlun Tongtai platform |
| Data Logging | ≥5 years local storage, GLP-compliant timestamped records |
| Remote Access | 4G/Wi-Fi enabled IoT gateway with role-based user management (1 admin + ≥20 users), SMS/WeChat alerting |
| Safety Systems | Dual-stage temperature safety cutoff, high/low pressure compressor protection, earth leakage detection, overcurrent/overheat coil monitoring, UV sterilization lamp (≥90 µW/cm², timer-controlled) |
| Air Quality | ISO Class 7 (10,000-grade) cleanroom performance (static): ≤350,000 particles/m³ @ 0.5 µm |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT80SH-2 / BAT150SH-2 / BAT250SH-2 / BAT520SH-2 |
| Air Circulation | Forced convection |
| Temperature Range | 4°C to 60°C |
| Temperature Accuracy | ±0.1°C |
| Temperature Uniformity | ±0.8°C (within same shelf plane) |
| Temperature Fluctuation | ±0.5°C |
| Capacity Options | 80 L / 150 L / 250 L / 520 L (modular multi-zone configuration) |
| External Dimensions | 895×590×1590 mm (BAT80SH-2) to 1150×870×1650 mm (BAT520SH-2) |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZSQ-1000HPG |
| Instrument Type | Semi-Automatic |
| Temperature Range | −10°C to 10°C (dark), 10°C to 45°C (light-on) |
| Temperature Uniformity | ±1.5°C |
| Humidity Range | 40–80% RH (light-on), 50–90% RH (light-off), within 15–45°C operational range |
| Humidity Uniformity | ±5% RH |
| Photosynthetic Photon Flux Density (PPFD) | 200–1500 μmol/m²/s (customizable, 0–100% stepless dimming) |
| Chamber Capacity | Customizable |
| External Dimensions | Customizable |
| Brand | Boante |
|---|---|
| Model | IBS-830A |
| Type | Temperature-Controlled Shaking Incubator |
| Drive | DC Motor |
| Amplitude | φ26 mm, φ50 mm |
| Temperature Range | 4–60 °C |
| Temperature Fluctuation | ±0.1 °C |
| Temperature Uniformity | ±1 °C |
| External Dimensions (3-Layer) | 970 mm × 720 mm × 1800 mm |
| Shelf Dimensions (per layer) | 530 mm × 500 mm |
| Internal Chamber Dimensions (per layer) | 580 mm × 550 mm × 360 mm |
| Capacity (per layer) | 250 mL × 30, 500 mL × 20, 1000 mL × 12, or 2000 mL × 6 |
| Speed Range | 0–300 rpm |
| Speed Accuracy | ±1 rpm |
| Display | OLED Touchscreen |
| Control System | PID Microprocessor-Based Intelligent Control |
| Air Circulation | Forced Convection |
| Timer Range | 0–999.9 h |
| Programming | 5 Preset Programs, up to 30 Segments per Program |
| Data Logging | 1-min Interval, 90-Day Storage, USB Export |
| Power Supply | AC 220 V, 50–60 Hz |
| Power Consumption | 1300 W |
| Net Weight (3-Layer) | 495 kg |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | IBS-830C |
| Instrument Type | Temperature-Controlled Shaking Incubator |
| Drive Mechanism | DC Motor Drive |
| Amplitude | φ3 mm |
| Temperature Range | 4–60 °C |
| Temperature Fluctuation | ±0.6 °C |
| Temperature Uniformity | ±1 °C |
| External Dimensions (3-Layer) | 970 mm × 720 mm × 1800 mm |
| Shaking Frequency | 0–1200 rpm |
| Frequency Accuracy | ±1 rpm |
| Internal Chamber Dimensions (per layer) | 580 mm × 550 mm × 360 mm |
| Shelf Plate Size (per layer) | 530 mm × 500 mm |
| Max Capacity (per layer) | 20 × 96-well plates |
| Power Supply | AC 220 V, 50–60 Hz |
| Power Consumption | 1300 W |
| Weight (3-layer) | 495 kg |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT70/150/250/360/460/600-SH |
| Air Circulation | Forced Convection |
| Temperature Range | 4°C to 60°C |
| Temperature Accuracy | ±0.1°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Uniformity | ±1.0°C (within same shelf plane) |
| Capacity | 70 L / 150 L / 250 L / 360 L / 460 L / 600 L |
| External Dimensions | 600×570×1220 mm (BAT70-SH) |
| Internal Dimensions | 400×350×500 mm (BAT70-SH) |
| Shelf Count | 2–4 adjustable stainless-steel shelves |
| Controller | Full-color LCD with PID algorithm, real-time parameter display, timer range 0–9999 min or 0–999 h |
| Safety Features | Compressor overheat protection, fan overheat protection, overtemperature cutoff, high-pressure shutdown, motor overload protection |
| Optional | UV germicidal lamp (for inner door or shelf), RS485/USB interface, thermal printer output, remote monitoring capability |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | IBS-620LS |
| Instrument Type | Temperature-Controlled Shaking Incubator |
| Oscillation Amplitude | φ26 mm |
| Temperature Range | 4–60 °C |
| Temperature Fluctuation | ±0.1 °C |
| Temperature Uniformity | ±1 °C |
| External Dimensions | 720 mm × 800 mm × 1300 mm |
| Oscillation Speed Range | 0–300 rpm |
| Speed Accuracy | ±1 rpm |
| Shelf Size | 485 mm × 485 mm |
| Max Capacity (per shelf) | 250 mL × 25 |
| Timer Range | 0–999.9 h |
| Power Supply | AC 220 V, 50–60 Hz |
| Power Consumption | 1000 W |
| Net Weight | 185 kg |
| Brand | Brookfield |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BAT50-JDH / BAT100-JDH / BAT150-JDH / BAT250-JDH |
| Air Circulation | Forced Horizontal Convection |
| Control Method | Digital PID Controller |
| Temperature Range | RT+5°C to 65°C |
| Temperature Control Accuracy | ±0.1°C |
| Temperature Uniformity | ±0.5°C (at 37°C) |
| Temperature Fluctuation | ±0.2°C |
| Capacity | 50 L / 100 L / 150 L / 250 L |
| External Dimensions (W×D×H) | 650×580×920 mm (BAT100-JDH reference) |
| Internal Chamber Material | Mirror-Finish Stainless Steel |
| Door Design | Double-Layer Insulated Glass with Sealed Gasket |
| Safety Features | Independent Over-Temperature Alarm (Audible & Visual) |
| Optional Interfaces | RS485 or USB for Data Logging & Remote Monitoring |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | IBS-930B |
| Instrument Type | Temperature-Controlled Shaking Incubator |
| Drive System | DC Motor Drive |
| Orbit Diameter | φ50 mm (optional φ26 mm) |
| Temperature Range | 4–60 °C |
| Temperature Fluctuation | ±0.1 °C |
| Temperature Uniformity | ±1 °C |
| External Dimensions (3-Layer) | 1450 mm × 950 mm × 1800 mm |
| Shaking Frequency | 0–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Temperature Resolution | 0.1 °C |
| Timer Range | 0–999.9 h |
| CO₂ Range | 0–20% |
| CO₂ Accuracy | ±0.1% |
| Max Capacity per Layer | 250 mL × 60 |
| Shelf Dimensions | 925 mm × 530 mm |
| Internal Dimensions per Layer | 1000 mm × 680 mm × 350 mm |
| Power Supply | AC 220 V, 50–60 Hz |
| Power Consumption | 1500 W |
| Weight (3-Layer) | 680 kg |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT360/600/800/1000ZW-4 |
| Temperature Range | 5–45 °C |
| Temp. Uniformity | ±0.5 °C (within chamber plane) |
| Temp. Stability | ±0.2 °C |
| Humidity Range | 40–80 %RH (with lights on) |
| Humidity Stability | ±5 %RH |
| Light Intensity | 0–800 lx (also specified as 0–1000 μmol·m⁻²·s⁻¹ at 100 mm distance) |
| Spectral Channels | 4 independent LED bands — 450 nm (blue), 660 nm (red), 730 nm (far-red), and 6500 K white light |
| Light Control | 0–100 % continuous dimming per channel |
| Illumination Mode | Top-mounted horizontal LED array with adjustable light-layer shelves |
| Chamber Volume | 600 L / 800 L / 1000 L |
| External Dimensions | 850×805×1900 mm (BAT600ZW-4) |
| Compliance | Designed for GLP-compliant plant phenotyping, photobiology, and controlled-environment research |
| Brand | Boante |
|---|---|
| Model | IBS-1020LSS |
| Drive Type | DC motor drive |
| Speed Range | 0–300 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | 4–60 °C |
| Temperature Fluctuation | ±0.1 °C |
| Temperature Uniformity | ±1 °C |
| External Dimensions | 1020 × 760 × 1400 mm |
| Internal Dimensions | 880 × 585 × 990 mm |
| Shelf Plate Size | 786 × 484 mm |
| Max Capacity (per shelf) | 250 mL × 40, 500 mL × 24, 1000 mL × 15, or 2000 mL × 11 |
| Power Supply | AC 220 V, 50–60 Hz |
| Power Consumption | 1500 W |
| Net Weight | 260 kg |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BAT70-GSH |
| Cooling Method | Compressor-based cooling |
| Temperature Range | 4–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Fluctuation | ±0.2 °C |
| Temperature Uniformity | ±0.5 °C (within same shelf plane) |
| Capacity Options | 70 L / 150 L / 250 L / 360 L / 600 L |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | IBS-320TS |
| Instrument Type | Temperature-Controlled Shaking Incubator |
| Drive Mechanism | DC Motor Drive |
| Orbital Amplitude | φ26 mm |
| Temperature Range | 4–60 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±0.1 °C |
| External Dimensions | 595 × 620 × 620 mm (W × D × H) |
| Internal Chamber Dimensions | 265 × 410 × 509 mm (W × D × H) |
| Shelf Plate Size | 440 × 320 mm |
| Max Capacity | 12 × 250 mL flasks, 8 × 500 mL flasks, or 6 × 1000 mL flasks |
| Oscillation Speed Range | 0–300 rpm |
| Speed Accuracy | ±1 rpm |
| Temperature Control Resolution | 0.1 °C |
| Timer Range | 0–999.9 h |
| Air Circulation | Forced Convection |
| Display | OLED Touchscreen |
| Control System | PID Microcomputer-Based Intelligent Control |
| Multi-Stage Programming | Yes |
| Data Logging | Continuous recording at 1-min intervals |
| Data Export | USB interface |
| Power Supply | AC 220 V, 50–60 Hz |
| Power Consumption | 1000 W |
| Net Weight | 92 kg |
| Brand | Boante |
|---|---|
| Model | BAT360-GZ |
| Temperature Range | 5–50 °C |
| Illumination Intensity | 0–600 μmol/m²/s (0–100% stepless dimming) |
| Uniformity | ±1 °C (within same shelf level) |
| Temperature Accuracy | ±0.1 °C |
| Control System | BAT200PG OS with 7-inch color touchscreen |
| Programmability | 24-segment time-temperature-light-humidity profile |
| Cooling Method | Hot-gas bypass refrigeration |
| Light Source Mounting | Top-mounted, horizontal, per-shelf independent control |
| Shelf Configuration | Adjustable spacing and quantity |
| Safety | Dual-limit temperature protection, compressor/fan overheat, overpressure, overload, and short-circuit safeguards |
| Data Logging | Internal storage ≥5 years |
| Compliance | Supports GLP-compliant audit trails (via optional USB/R485 data export), meets ISO 17025 environmental monitoring prerequisites for plant physiology labs |
| Brand | Boante |
|---|---|
| Model | BAT70/150/250/360/600-MGSH |
| Origin | Hubei, China |
| Control Method | Digital Touchscreen Interface |
| Air Circulation | Forced Convection |
| Temperature Range | 4°C to 60°C |
| Temperature Fluctuation | ±0.2°C |
| Temperature Uniformity | ±0.8°C (within same horizontal plane) |
| Capacity | 70 L / 150 L / 250 L / 360 L / 600 L |
| External Dimensions (W×D×H) | 570×600×1220 mm (BAT70) to 960×970×1790 mm (BAT600) |
| Internal Dimensions (W×D×H) | 400×350×500 mm (BAT70) to 800×680×1100 mm (BAT600) |
| Shelving | Adjustable Stainless Steel, 2–4 Levels |
| Safety Protections | Compressor Overheat, Fan Overheat, Overtemperature, High-Pressure Cut-off, Overload Protection |
| Optional Features | UV Germicidal Lamp (internal), RS485/USB Data Interface, Thermal Printer Output, Remote Monitoring via WeChat Mini-Program |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Temperature-Controlled Shaking Incubator |
| Drive System | DC Motor Drive |
| Speed Range | 0–300 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | φ26 mm |
| Temperature Range | 4–60 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±0.1 °C |
| External Dimensions | 1235 mm × 855 mm × 1400 mm |
| Power Supply | AC 220 V, 50–60 Hz |
| Rated Power | 1500 W |
| Net Weight | 300 kg |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Constant-Temperature Shaking Incubator |
| Drive System | DC Motor Drive |
| Orbit Diameter | φ26 mm |
| Temperature Range | 4–60 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±0.1 °C |
| External Dimensions | 1350 mm × 800 mm × 850 mm |
| Shaking Frequency Range | 0–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Temperature Control Resolution | 0.1 °C |
| Timer Range | 0–999.9 h |
| Air Circulation | Forced Convection |
| Display | OLED Touchscreen |
| Control Algorithm | PID Microcomputer Control |
| Platform Size | 1100 mm × 540 mm |
| Max Load Capacity | 250 mL × 60 |
| Power Supply | AC 220 V, 50–60 Hz |
| Rated Power | 1300 W |
| Net Weight | 240 kg |
| Brand | Boante |
|---|---|
| Model | IBS-830B |
| Type | CO₂ Shaking Incubator |
| Drive | DC Motor |
| Amplitude | φ50 mm (optional φ26 mm) |
| Temperature Range | 4–60 °C |
| Temperature Fluctuation | ±0.1 °C |
| Temperature Uniformity | ±1 °C |
| External Dimensions (3-layer) | 970 mm × 720 mm × 1800 mm |
| Shaking Frequency | 0–300 rpm |
| Frequency Accuracy | ±1 rpm |
| CO₂ Range | 0–20 % |
| CO₂ Accuracy | ±0.1 % |
| Internal Chamber Volume (per layer) | 580 mm × 550 mm × 360 mm |
| Shelf Plate Size (per layer) | 530 mm × 500 mm |
| Max Capacity (per layer) | 250 mL × 30 |
| Power Supply | AC 220 V, 50–60 Hz |
| Power Consumption | 1300 W |
| Weight (3-layer) | 490 kg |
| Brand | Boante |
|---|---|
| Model | BAT180/280/360/460/600GZ-4M & BAT180/280/360/460/600QH-4M |
| Temperature Range | 5–50 °C (10–50 °C with illumination) |
| Temperature Uniformity | ±1.0 °C (at same shelf level) |
| Humidity Range | 40–80 %RH (with lights ON) |
| Humidity Control Accuracy | ±1 %RH |
| Illuminance Range | 0–20,000 lx (7-step programmable intensity, measured at 100 mm from LED source) |
| Light Spectrum | 4000 K white LED, mounted on three inner door surfaces |
| Chamber Volume | 180 / 280 / 360 / 460 / 600 L |
| Control System | BAT200PG embedded OS with 5-inch color touchscreen interface |
| Programming | 24-segment time-based profile (real-time clock synchronized) for simultaneous independent control of temperature, humidity, and light intensity |
| Cooling Method | Thermal bypass refrigeration system |
| Safety Protections | Compressor overheat, fan overheat, overtemperature, high-pressure cut-off, overload protection |
| Construction | Double-glazed inner observation door |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT1080-WPG / BAT1600-WPG / BAT3200-WPG |
| Temperature Range | 5–45 °C (dark), 10–45 °C (light-on) |
| Temperature Uniformity | ±0.5 °C (within horizontal plane) |
| Temperature Stability | ±0.2 °C |
| Humidity Range | 40–80 %RH (light-on), 50–90 %RH (light-off), within 15–45 °C operating range |
| Humidity Control Accuracy | ±1 %RH |
| Light Intensity | 0–1200 µmol·m⁻²·s⁻¹ (measured at 100 mm from LED panel), 0–100 % infinitely adjustable |
| Light Source | High-efficiency white LED array, visible spectrum (400–700 nm) |
| Illumination Configuration | Top-mounted horizontal LED panels with modular, evenly distributed layout |
| Chamber Volume | 1080 L / 1600 L / 3200 L |
| External Dimensions (W×D×H) | 1800×770×1950 mm (BAT1080), 1850×900×2050 mm (BAT1600), 2980×1020×2050 mm (BAT3200) |
| Internal Dimensions (W×D×H) | 1200×600×1500 mm (BAT1080), 1250×800×1600 mm (BAT1600), 2350×850×1600 mm (BAT3200) |
| Max Plant Height Capacity | 1250 mm (BAT1080), 1350 mm (BAT1600 & BAT3200) |
| Total Cultivation Area | 0.63 m² (BAT1080), 1.03 m² (BAT1600), 1.82 m² (BAT3200) |
| Control System | BAT200PG embedded OS, 7-inch color touchscreen interface, 24-segment programmable cycle with real-time clock synchronization |
| Control Algorithm | Adaptive three-stage fuzzy logic APID (Adaptive Proportional-Integral-Derivative) for simultaneous temperature and humidity regulation |
| Data Logging | Internal storage for ≥5 years of timestamped environmental data (temperature, humidity, light intensity, operational status) |
| Safety Protections | Compressor overheat, fan overheat, overtemperature, high-pressure cutout, motor overload, door-open alarm |
| Defrost Method | Electromagnetic valve–controlled hot-gas bypass defrost |
| Optional Modules | CO₂ concentration control (0–2000 ppm), multi-spectral LED lighting (blue/red/far-red tunable), closed-loop dimming system, Ethernet/WiFi remote monitoring and control |
| Brand | Boante |
|---|---|
| Model | BAT600/800/1000/1250/1500/2000-SHM |
| Origin | Hubei, China |
| Temperature Range | 5–45 °C (10–45 °C under illumination) |
| Temperature Uniformity | ±0.5 °C (within same shelf plane) |
| Temperature Stability | ±0.2 °C |
| Humidity Range | 50–95 %RH (operable within 15–45 °C ambient) |
| Humidity Control Accuracy | ±1 %RH |
| Humidity Fluctuation | ±3 %RH (within same shelf plane) |
| Light Intensity Range | 0–600 µmol·m⁻²·s⁻¹ (0–100 % stepless dimming) |
| Light Source | LED, visible spectrum only |
| Illumination Configuration | Top-mounted horizontal lighting with per-shelf independent control |
| Chamber Volumes | 600 / 800 / 1000 / 1250 / 1500 / 2000 L |
| External Dimensions (W×D×H) | 850×805×1900 mm (BAT600-SHM) to 1980×920×2080 mm (BAT2000-SHM) |
| Internal Dimensions (W×D×H) | 740×585×1350 mm (BAT600-SHM) to 1874×728×1500 mm (BAT2000-SHM) |
| Shelving | 2-tier standard configuration |
| Cooling Method | Hot-gas bypass refrigeration with electromagnetic defrost |
| Control System | BAT200PG OS, 7-inch color touchscreen, 24-segment programmable timeline with real-time Beijing time synchronization |
| Security | Four-level password management (Factory Admin / User Admin / Operator / Engineer) |
| Data Logging | ≥5 years internal storage with timestamped audit trail |
| Safety Protections | Compressor overheat, fan overheat, over-temperature, high-pressure cut-off, overload protection |
| Brand | Brookfield |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BAT70-MSH / BAT150-MSH / BAT250-MSH / BAT360-MSH / BAT460-MSH / BAT600-MSH |
| Control Method | Mechanical Button Interface |
| Air Circulation | Forced Convection |
| Temperature Range | 4–60 °C |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ±1 °C (within same shelf plane) |
| Capacity | 70 L / 150 L / 250 L / 360 L / 460 L / 600 L |
| External Dimensions (W×D×H) | 600×570×1220 mm (BAT70-MSH) to 970×970×1790 mm (BAT600-MSH) |
| Internal Dimensions (W×D×H) | 400×350×500 mm (BAT70-MSH) to 800×680×1100 mm (BAT600-MSH) |
| Shelving | Adjustable Stainless Steel Racks (2–4 shelves depending on model) |
Show next