Empowering Scientific Discovery

Boant Instrumentation Technology (Wuhan) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBoante
OriginImported
Manufacturer TypeAuthorized Distributor
CO₂ Control Range (M-type)Ambient +100 ppm to 2000 ppm
CO₂ Control Range (MD-type)180 ppm to 2000 ppm (customizable)
CO₂ Detection Accuracy±1 ppm
CO₂ Control Accuracy±3% of setpoint
CO₂ Sensor TechnologyNDIR with Vaisala CARBOCAP® module
Response Time (0→2000 ppm)≤5 s
Concentration Step Response Time (100 ppm step)15 s
CO₂ Output Channels2 or 3
Air Output Channels2 or 3
Gas Flow Range (CO₂)0.16–1.6 L/min (optional high-flow: 0.4–6 L/min)
Pump TypeOil-free DC diaphragm pump
Flow Stability±0.3% FS
Noise Level≤42 dB(A)
Chamber MaterialStainless steel with corrosion-resistant coating
Calibration Interval12 months
Power SupplyAC 220 V ±10%, 50 Hz
Operating Temperature10–30 °C
Compatible MediaFreshwater, synthetic seawater, low-salinity and high-salinity seawater (≤45‰)
Control Interface7-inch capacitive touchscreen
Control AlgorithmAdaptive PID + fuzzy logic
Data LoggingReal-time timestamped gradient tracking with power-loss recovery
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBoante
Model RangeSC801M, SC802M, SC803M, SC804M, SC806M, SC801MD, SC802MD, SC803MD, SC804MD, SC806MD
Control Interface7-inch TFT touch screen
CO₂ Concentration Range (M)Ambient +100 ppm to 2000 ppm
CO₂ Concentration Range (MD)180 ppm to 2000 ppm (customizable)
Detection Accuracy±1 ppm
Control Accuracy±3% of setpoint
Sensor TypeNDIR infrared with Vaisala CARBOCAP® module
Response Time (Detection)≤5 s (0→2000 ppm step)
Concentration Adjustment Response Time15 s (100 ppm step)
CO₂ Flow Rate Range0.16–1.6 L/min (standard)
optional high-flow0.4–6 L/min
Air Flow RegulationYes
Number of CO₂ Output Channels1, 2, 3, 4, or 6
Air Output Channels1
Pump TypeOil-free DC diaphragm pump
Flow Stability±0.3% FS
Noise Level≤42 dB(A)
Enclosure MaterialStainless steel with corrosion-resistant white coating
Operating Temperature10–30 °C
Power SupplyAC 220 V ±10%, 50 Hz
Power Consumption100–220 W (model-dependent)
Calibration Interval12 months
Water CompatibilityFreshwater, synthetic media, low-salinity seawater, high-salinity seawater (≤45‰)
Control AlgorithmAdaptive PID + fuzzy logic
ComplianceDesigned for GLP-aligned environmental simulation workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBoante
OriginHubei, China
ModelBAT600-AR / BAT800-AR / BAT1000-AR / BAT1250-AR / BAT1700-AR / BAT2000-AR
Temperature Range5–45°C (dark), 10–45°C (with lighting)
Humidity Range40–80% RH (light on), 50–90% RH (light off) @ 15–45°C
Temp. Uniformity±0.5°C (per shelf level)
Temp. Control Accuracy±0.1°C
Humidity Control Accuracy±1% RH
Humidity Fluctuation±3% RH
Photosynthetic Photon Flux Density (PPFD)0–400 µmol/m²/s (0–100% dimmable, measured at 100 mm from lamp)
Air Exchange Rateup to 0.57 m³/min
Programmable Stages24-segment time-based scheduling with real-time Beijing time sync
Control SystemBAT200PG OS, 7-inch color touchscreen interface
Cooling MethodHot-gas bypass refrigeration
Defrost ModeSolenoid-valve controlled automatic defrost
Safety ProtectionsCompressor overheat, fan overheat, overtemperature, high-pressure cutout, overload protection
Data LoggingInternal storage for ≥5 years of operational records
User Access LevelsFour-tier password management (Factory Admin, User Admin, Operator Template, Engineer Template)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBoante
OriginHubei, China
ModelBAT600-PG / BAT800-PG / BAT1000-PG / BAT1250-PG / BAT1700-PG / BAT2000-PG
Temperature Range5–45°C (dark), 10–45°C (with lighting)
Humidity Range40–80% RH (light on), 50–90% RH (light off) @ 15–45°C
Temp Uniformity±0.5°C (per shelf)
Temp Accuracy±0.1°C
Humidity Accuracy±1% RH
Humidity Fluctuation±3% RH (per shelf)
Photosynthetic Photon Flux Density (PPFD)0–600 µmol/m²/s (0–100% dimmable, measured at 100 mm from lamp)
Optional UpgradesCO₂ control module, multi-spectral LED lighting (up to 800 µmol/m²/s), closed-loop dimming system, remote monitoring interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBoante
Model SeriesBAT700-FS, BAT800-FS, BAT1000-FS, BAT1100-FS, BAT1200-FS
Construction Material0.6–1.0 mm stainless steel (AISI 304 equivalent)
Layer Count7–12
Dimensions (W×D×H)140 × 145 × 400 mm to 140 × 145 × 700 mm
Compatible Storage Box Size133 × 133 × 54 mm (standard)
Capacity per Layer7–12 boxes (81-well paper or 100-well plastic cryoboxes)
Surface FinishSmooth deburred edges, electropolished weld zones
ComplianceDesigned for long-term operation at –80 °C and –196 °C (liquid nitrogen vapor phase)
Warranty12-month limited warranty covering material and workmanship defects under normal cryogenic use
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBoante
OriginImported
Manufacturer TypeAuthorized Distributor
PriceUpon Request
Photosynthetic Photon Flux Density (PPFD) at 150 cm500 μmol/m²/s
Spectral Range400–780 nm (continuous)
LED Channel Ratio (RedBlue:White:Far-Red): 4:2:2:2
Spectral Stability≤ ±5% fluctuation per channel
Rated LED Lifetime≥ 50,000 hours
Thermal ManagementAutomatic active cooling system