- All
- Favorite
- Popular
- Most rated
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | DCP 3000 + VSP 3000 |
| Measurement Principle | Thermal Conductivity (Pirani) |
| Measurement Range | 1×10³ mbar to 1×10⁻³ mbar |
| Accuracy | ±15% of reading (0.01–10 mbar) |
| Interface | KF DN 16 flange & DN 6/10 mm hose nipple |
| Dimensions (L×W×H) | 144 × 124 × 114 mm |
| Weight | 0.44 kg |
| Sensor Cable Length | 2 m |
| Bus Protocol | VACUU·BUS® digital bus |
| Max Connected Sensors | 8 (4×VSK 3000 + 4×VSP 3000) |
| Data Logging Capacity | 32,000 values |
| Housing Material | Chemically resistant PBT/PUR plastics & alumina ceramic |
| IP Rating | Splash-resistant (IEC 60529 IPX4 equivalent) |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | VACUU·VIEW® extended |
| Measurement Range | 1000 mbar to 1 × 10⁻³ mbar |
| Sensor Technology | Integrated ceramic diaphragm (capacitance manometer) + ceramic-encapsulated Pirani sensor |
| Chemical Resistance | Full compatibility with aggressive vapors and corrosive process gases |
| Display | Backlit LCD, menu-driven interface |
| Output | Analog (0–10 V) and digital (RS485/Modbus RTU) |
| Enclosure Rating | IP65 |
| Operating Temperature | 0–50 °C |
| Accuracy | ±2% of reading (full scale) in specified range |
| Long-term Stability | <0.5% drift/year |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | CVC 3000 Rough Vacuum Kit |
| Control Range | 1080–1 mbar |
| Control Method | Two-Point (On/Off) |
| Includes | CVC 3000 Controller, VV-B 6C Solenoid Valve, Plastic T-Fitting |
| Ordering Code | 683169 |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | CVC 3000 detect |
| Configuration | Desktop or Wall-Mountable |
| Sensor Type | Integrated Ceramic Capacitance Manometer |
| Control Principle | Two-Point Pressure Regulation with Vapor Pressure Detection (detect™) |
| Valve Type | Chemically Resistant Solenoid Vacuum Valve with Built-in Check Valve |
| Interface | Standard Laboratory Hose Fittings (e.g., DN 10, ISO-KF 10) |
| Functionality | Programmable Setpoint Control, Auto-Detection of Solvent Boiling Point via Dynamic Pressure Profile Analysis |
| Compliance | Designed for GLP/GMP-Compliant Laboratories |
| Software Integration | Optional PC Connectivity via RS232/USB (CVC Control Software v4.x) |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | DVR 2pro |
| Measurement Principle | Capacitive sensing via alumina ceramic diaphragm deflection under pressure differential |
| Range | 1–1060 mbar |
| Vacuum Interface | KF DN 16 flange and DN 6/10 mm hose nipple |
| Power Supply | 9 V Lithium battery (Ultralife U9VL, 1.2 Ah) |
| Display | Dual analog bar graph + digital numeric readout |
| Pressure Units | Selectable (mbar, hPa, Torr) |
| Accuracy | ±1 mbar / hPa / Torr (calibrated, isothermal conditions) |
| Sensor Material | Al₂O₃ ceramic membrane |
| EMC Performance | High immunity to electromagnetic interference (IEC 61326-1 compliant) |
| Dimensions (L×W×H) | ≈115 × 115 × 66 mm |
| Weight | ≈0.375 kg |
| Order No. | 20682906 |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | DCP 3000 + VSK 3000 |
| Measurement Range | 0.1 mbar to 1080 mbar |
| Sensor Type | Alumina ceramic diaphragm, capacitive absolute pressure |
| Accuracy | ±1 mbar (hPa/torr) at constant temperature |
| Interface | KF DN 16 flange, PTFE 10/8 mm, soft hose nozzles DN 6/10 mm |
| Dimensions | 144 × 124 × 114 mm |
| Weight | 0.44 kg |
| Max Cable Length | 2 m (sensor), up to 30 m (via VACUU·BUS®) |
| Data Logging Capacity | 32,000 values |
| Bus Protocol | VACUU·BUS® digital bus |
| Sensor Compatibility | up to 4 × VSK 3000 (0.1–1080 mbar) + 4 × VSP 3000 (10⁻³–1080 mbar) |
| Relative Pressure Option | Yes (with VSK 3000 as reference) |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CVC 3000 |
| Pricing | Upon Request |
| Vacuum Sensor | Integrated ceramic capacitive sensor |
| Control Range | 1080 mbar to 0.1 mbar |
| Measurement Uncertainty | ±1 mbar (hPa/torr) under calibrated, isothermal conditions |
| Vacuum Interface | 10/8 mm PTFE fitting, DN 6/10 mm hose nozzle (KF DN 16 flange optional) |
| Vent Valve Interface | Integrated, DN 4–5 hose nozzle |
| Dimensions (L×W×H) | 144 × 124 × 115 mm |
| Weight | 0.44 kg |
| Ordering Code | 683160 |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | VACUU·VIEW® |
| Measurement Range (Standard) | 1000 to 0.1 mbar |
| Measurement Range (Extended) | 1000 to 1×10⁻³ mbar |
| Sensor Type | Chemically Resistant Ceramic Capacitance Manometer |
| Accuracy | High repeatability and long-term stability across full range |
| Display | Backlit LCD, menu-driven interface |
| Units | mbar, hPa, Torr, psi (user-selectable) |
| Construction | All-in-one compact housing with integrated sensor |
| Compliance | Designed for laboratory and industrial vacuum process monitoring under ISO/IEC 17025-aligned operation |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | DVR 3pro |
| Measurement Principle | Alumina ceramic diaphragm, capacitive, gas-independent |
| Range | 1 – 1060 mbar |
| Vacuum Port Options | KF DN 16, PTFE 10/8 mm, or Bayonet DN 6/10 mm |
| ATEX Certification | II 2G Ex ib IIC T4 Gb |
| Power Supply | 9 V alkaline battery (non-rechargeable) |
| Typical Battery Life | 4,000 h (operational), 30,000 h (standby) |
| Housing Material | Chemically resistant rigid plastic |
| IP Rating | IP40 |
| Operating Temperature | 10–40 °C |
| Storage Temperature | −10–60 °C |
| Auto-Off | User-selectable (1–600 min or continuous) |
| Measurement Cycle | Auto, 3 s, 1 s, or 0.33 s |
| Accuracy | ±1 mbar/hPa/torr (calibrated, isothermal) |
| Temperature Coefficient | < 0.15 mbar/hPa/K |
| Max. Steam Temp. | 40 °C (continuous), 80 °C (short-term) |
Show next