Anton Paar
Filter
Showing 61–90 of 92 results
| Brand | Anton Paar |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Anton Paar (Shanghai) Co., Ltd. |
| Product Type | Domestic Manufacturing |
| Model | Multiwave 5001 CN |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 96 samples per batch |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300 °C |
| Temperature Measurement Accuracy | ±0.1 °C |
| Temperature Control Stability | ±1 °C |
| Temperature Uniformity | ±1 °C |
| Max Pressure | 100 bar |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Multiwave 5001CN |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 96 samples |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 100 bar |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Multiwave 7101 / 7301 / 7501 |
| Cavity Class | Industrial-Grade |
| Sample Capacity | Up to 41 positions (configurable) |
| Microwave Source | Single 2000 W Magnetron |
| Max Temperature | 300 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±0.3 °C |
| Temp Uniformity | Full-cavity uniformity (no spatial gradient) |
| Max Pressure | 199 bar |
| Brand | Anton Paar |
|---|---|
| Country of Origin | Austria |
| Model | Multiwave GO Plus |
| Cavity Class | Industrial-grade |
| Sample Capacity | 12 samples per run |
| Microwave Source | Industrial Magnetron |
| Max Temperature | 260 °C / 300 °C (depending on vessel type) |
| Max Pressure | 2200 psi |
| Cooling Time (12-position rotor, 180 °C → 70 °C) | ≤8 min (EPA-compliant) |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NHT³ |
| Instrument Type | Nanoindentation Tester |
| Maximum Indentation Depth | 200 µm |
| Effective Load Range | 0.1 mN to 500 mN |
| Load Resolution | 20 nN |
| Load Noise (RMS) | ≤0.5 µN |
| Depth Resolution | 0.01 nm |
| Depth Noise (RMS) | ≤0.15 nm |
| Loading Rate | up to 10,000 mN/min |
| Data Acquisition Rate | 192 kHz |
| Environmental Options | Liquid Testing Compatible |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | NST³ |
| Instrument Category | Nanoindentation and Scratch Tester |
| Maximum Indentation Depth | 1 µm |
| Load Resolution | 0.01 µN |
| Displacement Range | 600 µm |
| Maximum Friction Force | 1 N |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Oxy 5100 |
| Price | Upon Request |
| Resolution | 0.4 ppb |
| Measurement Range | 0–2000 ppb or 0–24 ppm |
| Repeatability | ≤0.5 ppb or ≤1 % of reading |
| Long-term Stability | ≤0.8 ppb per 24 h |
| Temperature Compensation Range | –5 °C to +40 °C |
| Communication Interfaces | Analog Output (AO), Analog Input (AI), Digital Input (DI), Digital Output (DO), CAN bus |
| Dimensions (H × W × D) | 174 mm × 174 mm × 230 mm |
| Operating Ambient Temperature | –5 °C to +50 °C |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | OxyQC Wide Range |
| Price | Upon Request |
| Measurement Range (O₂) | 0.015 ppm to 45 ppm |
| Temperature Range | −3 °C to 40 °C (±0.2 °C accuracy) |
| Pressure Range | 0 to 10 bar absolute (±0.01 bar accuracy) |
| Repeatability | ±2 ppb (<200 ppb), ±20 ppb (<5 ppm) |
| Resolution | 0.1 ppb (<100 ppb), 1 ppb |
| Sample Volume | >100 mL (standard), >150 mL (with optional flow cell) |
| Measurement Time | ≤50 s |
| Data Storage | 500 measurement datasets |
| Display | High-contrast color LED touchscreen |
| Protection Rating | IP67 |
| Battery Life | Up to 11 hours (portable operation) |
| Interfaces | 1× RS-232, 1× USB |
| Dimensions (L×W×H) | 262 × 209 × 176 mm |
| Weight | 1.7 kg |
| Units Supported | ppm, ppb, mg/L, µg/L, hPa, % Air-sat., % O₂-sat. |
| Built-in Features | O₂ data logger, threshold alarms, system self-check |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Perfume and Flavor Measurement System |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Class | Benchtop Laboratory |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.01 g/cm³ |
| Display | 10.1″ TFT WXGA (1280 × 800 px) PCAP Touchscreen |
| Temperature Control Range | 0–100 °C |
| Minimum Sample Volume | 2 mL |
| Integrated Parameters | Density, Refractive Index, Optical Rotation, Colorimetry, Turbidity |
| Automation | Fully Automated Sample Handling with Recovery (Xsample 5200/530), Integrated Cleaning & Drying |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | PNR 12 |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PoreMaster |
| Price | Upon Request |
| Pore Size Range | 30 nm – 600 µm |
| Pressure Range | 0.01 – 50 MPa |
| Measurement Accuracy | ≤ 0.5% |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PTD 100 Cone-Plate, Order Code 253764 |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Model | iSorb HP |
| Measurement Method | Static Volumetric Method |
| Temperature Range | 75 K to 773 K (-198 °C to 500 °C) |
| Pressure Range | 0.0005 bar to 200 bar (absolute) |
| Ultimate Vacuum | 1×10⁻⁹ mbar |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Nova 600BET / 800BET / 600 / 800 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 4 |
| Specific Surface Area Range | ≥ 0.01 m²/g (no upper limit) |
| Pressure Range | 1×10⁻⁴ to 0.999 P/P₀ |
| Supported Theoretical Models | BET, Langmuir, t-plot, DFT (NLDFT/QSDFT), BJH, DH, DR, HK, SF |
| Repeatability | < 2% |
| Operating Temperature | 15–35 °C |
| Absolute Pressure Resolution | 1.2×10⁻⁴ Torr |
| Relative Pressure Resolution | 1.5×10⁻⁷ P/P₀ |
| Pore Diameter Range | 0.35–500 nm (0.35–1.1 nm with CO₂ at 273 K) |
| Minimum Detectable Pore Volume | 1.2×10⁻⁸ cm³ |
| Integrated Degassing Stations | 4 (programmable, up to 425 °C) |
| Dewar Capacity | 2 L (up to 40 h operation) |
| Dimensions (D×W×H) | 44 × 63 × 84 cm |
| Weight | 63 kg |
| Power Supply | AC 100–240 V, 50/60 Hz, max. 345 VA |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Ultrapyc Series |
| Instrument Type | True Density Analyzer |
| Instrument Class | Benchtop Laboratory |
| Sample Type | Solids (bulk & granular), Powders, Pastes, Slurries, Foams |
| Density Accuracy | ≤0.015% |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Temperature Range | 3–60 °C |
| Minimum Sample Volume | 0.1 cm³ |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | RapidOxy 100 |
| Pricing | Available upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | RheolabQC |
| Instrument Type | Rotational Rheometer |
| Sample State | Liquid |
| Minimum Speed | 0.01 rpm |
| Maximum Speed | 1200 rpm |
| Torque Range | 0.20 mN·m to 75 mN·m |
| Shear Stress Range | 0.5–3×10⁴ Pa |
| Shear Rate Range | 10⁻²–4000 s⁻¹ |
| Viscosity Range | 1–10⁹ mPa·s (dependent on geometry) |
| Temperature Range | −20 °C to +180 °C |
| Angular Displacement Resolution | 2 µrad |
| Compliance | FDA 21 CFR Part 11, ISO 16520, ASTM D2196, D445, D1093 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | SAXSpace |
| Instrument Type | Small-Angle and Wide-Angle X-ray Scattering (SAXS/WAXS) System |
| q-Range | 0.03–49 nm⁻¹ |
| Real-Space Resolution Range | 0.13–200 nm |
| Maximum 2θ | 74° |
| X-ray Source | Sealed-tube (line or point focus) |
| Beam Size | 20 × 0.3 mm² (line), 0.3 × 0.3 mm² (point) |
| Operating Voltage | 40 kV |
| Operating Current | 50 mA |
| Minimum Sample Volume | 7 µL (liquid), few mg (solid) |
| Temperature Control Range | −150 to 300 °C (±0.1 °C stability) |
| Measurement Time | 1–60 min |
| Automation | Motorized optical alignment, in situ heating/cooling, liquid handling compatibility |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SAXSpoint 500 |
| Instrument Type | Small-Angle X-ray Scattering (SAXS) System |
| q-Range | 0.02 nm⁻¹ to 43 nm⁻¹ |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | SmartPave |
| Instrument Type | Rotational Rheometer |
| Sample Viscosity Range | High-Viscosity |
| Sample State | Liquid |
| Bearing Type | Air Bearing |
| Temperature Range | −160 °C to +1000 °C |
| Minimum Rotational Speed | 0 rpm |
| Frequency Range | 10⁻⁷ to 1256 rad/s |
| Maximum Rotational Speed | 3000 rpm |
| Maximum Torque | 215 mNm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | SmartPave |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 0 rpm |
| Frequency Range | 10⁻⁷ – 628 rad/s |
| Maximum Rotational Speed | 3000 rpm |
| Maximum Torque | 200 mNm |
| Torque Resolution | < 0.1 nNm |
| Normal Force Range | 0.01 – 50 N |
| Normal Force Resolution | 1 mN |
| Temperature Range | −40 °C to +120 °C |
| Compliance Standards | AASHTO T315, T316, TP70, TP101, ASTM D7175, D4402, D7405, DIN EN 13302, DIN EN 14770 |
| Toolmaster™ | Yes |
| TruGap™ | Yes |
| T-Ready™ | Yes |
| Automatic Gap Control (AGC) | Yes |
| Peltier-based Dry Heating | Yes |
| Ethernet Interface | Yes |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | STEP x01 |
| Instrument Category | Nanoindentation and Scratch Tester |
| Indenter Tip Material | Diamond |
| Base Platform | Modular Mechanical Surface Testing System |
| Maximum Load Capacity | Not specified in input |
| Compliance | GLP/GMP-ready architecture, ASTM E2546, ISO 14577, ISO 20502, USP <1089> compatible (inferred from platform class) |
| Vibration Isolation | Optional active damping table & acoustic enclosure |
| Microscopy | Dual-view optical microscope (20×–10,000× continuous zoom) |
| Positioning Accuracy | <1 µm over extended scan range |
| Automation Interface | Integrated for factory-floor QC integration |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | SurPASS 3 |
| Measurement Principle | Streaming Potential Method |
| pH Range | pH 2 – pH 12 |
| Temperature Range | 20 °C to 40 °C |
| Temperature Control | Integrated Peltier-based thermostating |
| Sample Compatibility | Flat solids (min. 20 mm × 10 mm, ≤2 mm thick |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SVM Series |
| Instrument Category | Kinematic Viscometer |
| Instrument Form Factor | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Kinematic Viscosity Range | 0.2 to 30,000 mm²/s |
| Temperature Control Range | 15 °C to 100 °C (standard) |
| Compliance | ASTM D7042, ASTM D445 (with bias correction), ISO 23581, EN 16896, ASTM D4052, ISO 12185, ASTM D2386, ASTM D2500, ASTM D396, D975, D1655, D3699, D6158, D6823, D7467 |
| Patents | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1), AT516302 (B1), CN105628550 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | SVM™ 2001 / SVM™ 3001 / SVM™ 4001 |
| Viscosity Range | 0.2 to 30,000 mm²/s |
| Temperature Range | +15 °C to +100 °C (SVM™ 2001 & 4001) |
| Density Range | 0.6 to 3.0 g/cm³ |
| Sample Volume | 1.5–6 mL |
| Compliance | ASTM D7042, ISO 12185, EN 16896, ASTM D4052, ISO 2909, ASTM D2270, ISO 91, ASTM D1250, ASTM D2161 |
| Cooling | Integrated Peltier (down to –20 °C) |
| Power | AC 100–240 V, 50–60 Hz, max. 250 VA |
| Dimensions (W × D × H) | 33 × 51 × 23.1 cm |
| Net Weight | 15.9–17.8 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | TAG 300/500 |
| Detection Method | Closed-Cup (TAG) |
| Operation Mode | Fully Automatic |
| Sample Temperature Range | −35 °C to +130 °C |
| Ignition Source | Ceramic-Coated Electric Igniter |
| Compliant Standards | ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer | Anton Paar GmbH |
| Type | High-Temperature Tribological Tester |
| Model | THT |
| Maximum Friction Force | 20 N |
| Friction Force Resolution | 0.03 mN |
| Maximum Operating Temperature | 1000 °C |
| Rotational Speed Range | 0.3–500 rpm (optional up to 1500 rpm) |
| Maximum Torque | 450 N·mm |
| Compliance Standards | DIN 50324, ASTM G99, ASTM G133 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TPO 5000 |
| Instrument Type | Beer-Specific Analyzer |
| Application Mode | Online & Laboratory |
| Measurement Time | 4 min |
| Dimensions (L × W × H) | 515 × 590 × 1120 mm |
| Weight | 70 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer | Anton Paar GmbH |
| Type | Multifunctional Tribological Tester |
| Model | TRB³ |
| Maximum Normal Force | 60 N |
| Normal Force Resolution (net weight) | Not specified |
| Maximum Friction Force | 20 N (optional 5 N) |
| Friction Force Resolution | 0.015 mN (optional 0.06 mN) |
| Rotational Speed Range | 0.2–2000 rpm (optional up to 600 rpm) |
| Linear Reciprocating Stroke | up to 60 mm |
| Linear Reciprocating Speed | up to 370 mm/s |
| Linear Frequency Range | 0.01–10 Hz |
| Oscillatory Rotational Speed | 0.2–2000 rpm |
| Oscillatory Frequency Range | 0.01–7 Hz |
| Angular Amplitude Range | ±5° to ±150° |
| Angular Resolution | 0.1° |
| Heating Capability | up to 450 °C (dry), up to 150 °C (liquid) |
| Vacuum Level | down to 10⁻⁷ mbar |
| Relative Humidity Control | 15–95% RH |
| Contact Resistance Measurement | up to 1000 Ω |
| Online Wear Depth Measurement (optional) | −2 to +2 mm |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer | Anton Paar GmbH |
| Type | Nanoindentation and Scratch Tester |
| Model | UNHT³ |
| Indentation Depth Range | 0–100 µm |
| Load Range | 10 µN – 100 mN |
| Load Resolution | 3 nN |
| Displacement Resolution | 0.003 nm |
| Thermal Drift | <3 nm/min |
| Frame Stiffness | >10⁸ N/m |
| Compliance with Standards | ISO 14577, ASTM E2546 |