Cimel
Filter
Showing all 7 results
| Brand | Cimel |
|---|---|
| Origin | France |
| Model | CE312 |
| Instrument Type | Portable Radiometric Sensor |
| Application Domain | Environmental Monitoring, Atmospheric Science, Remote Sensing Calibration |
| Spectral Configuration | CE312-1 (4-band) or CE312-2 (6-band) |
| Temperature Range | −80 °C to +60 °C |
| Temperature Resolution | 0.01 °C |
| Response Time | 1 s |
| Field of View | 10° |
| Operating Ambient Temperature | −20 °C to +50 °C |
| Power Supply | Integrated Rechargeable Battery (12 V), Optional Solar Panel |
| Data Storage | Internal Memory via Control Box |
| Measurement Modes | Manual Sampling, Programmable Timed Acquisition |
| Spectral Bands | CE312-1: 8–13 µm, 8.2–9.2 µm, 10.3–11.3 µm, 11.5–12.5 µm |
| CE312-2 | 8–13 µm, 8.1–8.5 µm, 8.5–8.9 µm, 8.9–9.3 µm, 10.3–11.0 µm, 11.0–11.7 µm |
| Brand | Cimel |
|---|---|
| Origin | France |
| Model | CE318 |
| Instrument Type | Aerosol Optical Depth (AOD) & Sky Radiance Spectroradiometer |
| Standard Spectral Channels | 340, 380, 440, 500, 675, 870, 936, 1020, 1640 nm (FWHM ≤ 10 nm) |
| Field of View | 1.3° (full width at half maximum) |
| Detector Configuration | Enhanced silicon photodiode (direct sun), silicon photodiode (sky radiance) |
| Solar Tracking Accuracy | < 0.1° (dual-axis stepper motor + quadrant detector fine adjustment) |
| Operating Temperature Range | −30 °C to +60 °C |
| Power Supply | Internal battery (optical head), external battery (motor drive) |
| Data Interfaces | RS-232 serial, USB, optional Wi-Fi/3G/Geostationary Satellite (Meteosat/GOES/GMS) telemetry |
| Environmental Protection | Automatic rain shutdown via integrated hygrometer |
| Brand | Cimel |
|---|---|
| Origin | France |
| Model | CE332 |
| Instrument Type | Spectroradiometer |
| Spectral Channels | 3 thermal infrared bands |
| Central Wavelengths | 8.7 µm (1.0 µm FWHM), 10.8 µm (1.0 µm FWHM), 13.0 µm (1.0 µm FWHM) |
| Measurement Frequency | 6.25 Hz (EU) / 7.5 Hz (US) |
| NEDT | ≤0.03 °C at 20 °C |
| Temperature Range | –30 °C to +50 °C |
| Field of View | 3° |
| Temperature Resolution | 0.001 °C |
| Temperature Accuracy | ±0.01 °C |
| Integration Time | 10 ms |
| Bandwidth | ~2 Hz |
| GPS Synchronization | Yes |
| Calibration | In-flight manual rapid recalibration supported |
| Housing | Dual-layer insulated, hermetically sealed for airborne operation |
| Communication | RS-232 interface (max. cable length: 150 m) |
| Power Supply | 12 V DC |
| Weight | 2.4 kg |
| Dimensions | 13 cm (W) × 20 cm (H) × 13 cm (D) |
| Software | Airborne Radiometer v1.0 (Windows 95/98/ME/NT4/2000 compatible) |
| Data Output | Real-time 1- or 3-channel radiance & brightness temperature |
| Brand | Cimel |
|---|---|
| Origin | France |
| Model | CE350 |
| Instrument Type | Portable Radiometer |
| Measurement Domain | Atmospheric and Submersible Radiance Distribution |
| Spectral Channels (nm) | 406, 438, 494, 510, 560, 628 |
| Radiance Range | 5×10⁻⁵ – 1 W·m⁻²·nm⁻¹·sr⁻¹ |
| Field of View | ±92° |
| Sensor | Anti-blooming CMOS |
| Dynamic Range | 5 decades |
| Physical Dimensions | Ø96 mm × 260 mm |
| Remote Operation Distance | Up to 200 m (fiber-optic or shielded cable) |
| Integrated Auxiliary Sensors | Digital compass, tilt sensor, pressure (depth), temperature, humidity |
| Optical Design | Patented telecentric hemispherical lens with motorized filter wheel |
| Brand | CIMEL |
|---|---|
| Origin | France |
| Model | CE370-2 |
| Eye-Safe Laser Pulse Energy | 8–12 µJ |
| Laser Wavelength | 532 nm |
| Pulse Repetition Rate | 5 kHz |
| Pulse Width | <12 ns |
| Telescope Type | Galilean |
| Aperture Diameter | 200 mm |
| Effective Focal Length | 900 mm |
| Field Stop | Double |
| Total Field of View (FOV) | 55 µrad (standard fiber) / 55/110 µrad (enhanced fiber) |
| Detector | Si APD with 55% Quantum Efficiency |
| Filter Bandwidth | 0.2 nm |
| Spatial Resolution | 15 m |
| Maximum Detection Range | Up to 30 km (atmosphere-dependent) |
| Range Gates | 2048 |
| Data Acquisition Mode | Photon Counting |
| Maximum Counting Rate | 20 Mc/s |
| Operating Temperature | –10 °C to +40 °C |
| Power Supply | 100/115/230 VAC, ≤500 W |
| Weight | 35 kg |
| Enclosure | 6U Rack-mounted Electronics + Telescope (Ø220 mm × 500 mm) |
| Fiber Interconnect | 10 m optical fiber |
| Optional Dual-Axis Scanner | Azimuth –180° to +180°, Zenith 0° to 90°, Positional Accuracy ±3′ |
| Brand | Cimel |
|---|---|
| Origin | France |
| Model | ENERCO 400 |
| Type | Portable Weather Station |
| Certification | Compliant with WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No. 8) |
| Power Supply | Integrated solar panel + rechargeable battery (5 V, <1 mA standby current) |
| Data Interface | RS-232 serial output |
| Environmental Rating | IP65 enclosure (ventilated, waterproof, humidity-resistant) |
| Operating Altitude | Up to 5,000 m ASL |
| Operating Temperature Range | −40 °C to +60 °C |
| Sensor Mounting | Modular hollow-arm assembly with plug-in, electrically isolated sensor interfaces |
| Data Logging Interval | Configurable from 5 s (temperature, wind) to 60 s (barometric pressure, water level) |
| Battery Autonomy | ≥30 days without solar charging |
| Compliance | Designed for GLP-aligned environmental monitoring |
| Brand | Cimel |
|---|---|
| Origin | France |
| Model | CE376 |
| Laser Sources | Frequency-doubled Nd:YAG (532 nm), Pulsed Laser Diode (<850 nm) |
| Detectors | APD with QE 55% / 70% |
| Operating Wavelengths | 532 nm (green) and <850 nm (NIR) |
| Maximum Detection Altitude | 13 km |
| Pulse Repetition Rate | 5000 Hz |