CMC (Himsi)
Filter
Showing all 8 results
| Brand | CMC (Himsi) |
|---|---|
| Origin | Germany |
| Model | iTMA-202-P |
| Instrument Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature | +5 to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10, 0–100, 0–1000, 0–2500 ppm H₂O (auto/manual range switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with optional Chinese language support |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | High/Low alarm (user-definable thresholds) |
| Power Supply | Internal rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Dimensions | 363 × 115 × 377 mm (W × H × D) |
| Weight | ~6 kg |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Brand | CMC (HimSi) |
|---|---|
| Origin | Germany |
| Model | TMA-202 |
| Application | Online dew point measurement in corrosive and combustible gases |
| Principle | Phosphorus pentoxide (P₂O₅) electrolytic sensor |
| Operating Temperature | -10 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–2500 ppm (auto/manual range switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| Environmental Operating Range | 5–65 °C |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Display | Touchscreen with optional Chinese language interface |
| Enclosure Options | 19" rack-mount (482 × 133 × 350 mm), wall-mount (300 × 260 × 280 mm), benchtop (257 × 160 × 316 mm), and ATEX-certified variants (TMA-202-Ex series) |
| Brand | CMC (HimSi) |
|---|---|
| Origin | Germany |
| Model | TMA-202-W |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -10 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range Options | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–2,500 ppm (auto/manual switching) |
| Sensitivity | 0.1% of full scale |
| Analog Output | 4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| T₅₀ Response Time | <8 s |
| Ambient Temperature Range | 5–65 °C |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Dimensions | 300 mm (W) × 260 mm (H) × 280 mm (D) |
| Brand | CMC (HimSi) |
|---|---|
| Origin | Germany |
| Model | TMA-204 |
| Product Type | Online Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | +5 to +50 °C |
| Accuracy | ±1% of Full Scale |
| Repeatability | ±0.1% of Full Scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (Auto- or Manual-Range Selection) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with Multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 Relay Outputs |
| Enclosure Options | 19" Rack-Mount (482 × 133 × 350 mm), Wall-Mount (300 × 260 × 280 mm), Benchtop (257 × 160 × 316 mm), ATEX/IECEx Certified Variants Available |
| Cable Length | Standard 3 m, Optional up to 300 m |
| Brand | CMC (Himsi) |
|---|---|
| Origin | Germany |
| Model | TMA-204-P-Ex |
| Type | Portable Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5–50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range | 0–10 / 100 / 1,000 / 2,500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual support (including Chinese) |
| Output | 0/4–20 mA (configurable) |
| Alarms | High/Low limit (user-definable) |
| Intrinsic Safety | Integrated Zener barrier (Ex ia IIC T4 Ga) |
| Power | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Dimensions | 363 × 115 × 377 mm |
| Weight | ~6 kg |
| Brand | CMC (HimSi) |
|---|---|
| Origin | Germany |
| Model | TMA-210-P |
| Instrument Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature Range | +5 °C to +150 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–2,500 ppm (auto/manual range switching) |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Alarm Outputs | Configurable high/low limit relays |
| Analog Output | 4–20 mA (user-configurable) |
| Power Supply | Internal rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Environmental Operating Temp. | −10 °C to +50 °C |
| Enclosure Rating | IP20 |
| Dimensions | 363 mm (W) × 115 mm (H) × 377 mm (D) |
| Weight | ~6 kg |
| Brand | CMC (HimSi) |
|---|---|
| Origin | Germany |
| Model | TMA-404 |
| Type | In-line Dew Point / Moisture Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5–50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Range | 0–1 / 10 / 100 / 1000 ppmᵥ (auto/manual range switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Power Supply | 80–230 VAC, 50–60 Hz |
| Enclosure Options | Rack-mount (482 × 133 × 350 mm), Wall-mount (300 × 260 × 280 mm), Bench-top (257 × 160 × 316 mm) |
| Weight | ~6 kg |
| Brand | CMC (Himsi) |
|---|---|
| Origin | Germany |
| Model | ZA2000T |
| Maximum Flow Rate | 2000 mL/min |
| Outlet Hydrocarbon Concentration | <0.05 ppm CH₄ |
| Inlet Hydrocarbon Limit | ≤100 ppm CH₄ |
| Startup Time | 10 min |
| Power Supply | 230 VAC, 50 Hz |
| Power Consumption | <30 W/h |
| Startup Power | 420 W |
| Dimensions (H×W×D) | 270 × 340 × 460 mm |
| Weight | 13 kg |
| Noise Level | Silent Operation |
| Compliance | Designed for GC-FID zero air supply per ASTM D6216, ISO 8573-1 Class 1, and USP <641> gas purity requirements |