CUBIC INSTRUMENTS
Filter
Showing 1–30 of 244 results
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Model | Gasboard 3500 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Gases | O₂, CO, CO₂, H₂S, CH₄ |
| Accuracy | ±0.5–2% F.S. (gas- and range-dependent) |
| Resolution | 0.01% vol to 1 ppm |
| Response Time | <40 s |
| Sample Flow Rate | 0.7–1.2 L/min |
| Explosion Protection | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Output Interfaces | RS-485, RS-232, 4–20 mA |
| Power Supply | AC 220 V, 50 Hz |
| Display | LCD |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard 3500 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Gases | O₂, CO, CO₂, H₂S, CH₄ |
| Explosion Protection Rating | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Response Time | <40 s |
| Sample Flow Rate | 0.7–1.2 L/min |
| Output Signals | RS-485 / RS-232 / 4–20 mA |
| Display | LCD |
| Power Supply | AC 220 V, 50 Hz |
| Auto-Zero Function | Integrated air pump for in-situ zero calibration |
| Diagnostic Capability | Real-time sensor health monitoring |
| Preconditioning | Integrated front-end sample conditioning for wet, dusty, and oily gas streams |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000GHG |
| Measurement Principle | Micro-flow NDIR (CO₂/CH₄/N₂O/CO), Dual-beam NDIR (CO₂ high-range & CO mid-high range), Electrochemical (O₂) |
| Accuracy | ±1% F.S. (micro-flow NDIR), ±2% F.S. (dual-beam NDIR & ECD) |
| Measured Gases | CO₂, CH₄, N₂O, CO, O₂ |
| Response Time | T₉₀ < 25 s |
| Repeatability | ≤ ±1% |
| Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Sample Requirements | Dew-free (no condensation), particulate filtration (<1 µm) |
| Output | RS-485/RS-232, (4–20) mA |
| Power | 100–240 VAC, max 300 W (heating), stable 100 W |
| Diagnostic Function | Real-time sensor health monitoring |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000GHG |
| Detection Principle | Micro-flow NDIR (CO₂/CH₄/N₂O/CO) |
| Accuracy | ±1% F.S. (micro-flow NDIR), ±2% F.S. (dual-beam NDIR & ECD) |
| Measured Gases | CO₂, CH₄, N₂O, CO, O₂ |
| Response Time | T₉₀ < 25 s |
| Repeatability | ≤ ±1% |
| Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Sample Requirements | Dew-free (no condensation), particulate filtration (<1 µm) |
| Output | RS-485/RS-232, 4–20 mA |
| Power | 100–240 VAC, 300 W (max heating), 100 W (steady-state) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000GHG |
| Detection Principle | Micro-flow NDIR (CO₂/CH₄/N₂O/CO) |
| Accuracy | ±1% F.S. (micro-flow NDIR), ±2% F.S. (dual-beam NDIR & ECD) |
| Measured Gases | CO₂, CH₄, N₂O, CO, O₂ |
| Response Time | T₉₀ < 25 s |
| Repeatability | ≤ ±1% |
| Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Output | RS-485/RS-232, 4–20 mA |
| Power | 100–240 VAC, max 300 W (heating), stable 100 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000GHG |
| Detection Principle | Micro-flow NDIR (CO₂/CH₄/N₂O/CO), Dual-beam NDIR (CO₂ high-range & CO mid-high range), Electrochemical (O₂) |
| Accuracy | ±1% F.S. (micro-flow NDIR), ±2% F.S. (dual-beam NDIR & ECD) |
| Measured Gases | CO₂, CH₄, N₂O, CO, O₂ |
| Response Time | T₉₀ < 25 s |
| Repeatability | ≤ ±1% |
| Flow Rate | 0.7–1.2 L/min |
| Sample Pressure | 2–50 kPa |
| Output | RS-485/RS-232, 4–20 mA |
| Power | 100–240 VAC, max 300 W (heating), stable 100 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000UV |
| Measurement Principle | UV-Differential Optical Absorption Spectroscopy (UV-DOAS) for SO₂/NO/NO₂ |
| Measurement Range | SO₂/NO/NO₂: 0–100 mg/m³ |
| O₂ | 0–25% (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤2% |
| Response Time (T90) | ≤30 s |
| Stability | ≤±2% F.S./24 h |
| Linearity Error | ≤±2% F.S. |
| Sample Requirements | Condensate-free, particulate filtration <1 µm |
| Operating Humidity | 5–85% RH |
| Ambient Pressure | 86–108 kPa |
| Communication | Dual RS-232/RS-485 ports, Modbus RTU protocol (customizable) |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | 200 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Model | Gasboard-3000UV |
| Measurement Principle | UV-Differential Optical Absorption Spectroscopy (UV-DOAS) for SO₂, NO, NO₂ |
| Measurement Range | SO₂/NO/NO₂: 0–100 mg/m³ |
| O₂ | 0–25% (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤2% |
| Response Time (T₉₀) | ≤30 s |
| Stability | ≤±2% F.S./24 h |
| Linearity Error | ≤±2% F.S. |
| Sample Requirements | Liquid-free, particulate filtered (<1 µm) |
| Operating Humidity | 5–85% RH |
| Ambient Pressure | 86–108 kPa |
| Communication | Dual RS-232/RS-485, Modbus RTU protocol (customizable) |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | 200 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3002 |
| Principle | Micro-flow NDIR (Non-Dispersive Infrared) Absorption |
| Type | Portable |
| Response Time | <60 s |
| Repeatability | ±2% F.S. |
| SF₆ Purity Range | 0–100% vol |
| Resolution | 0.01% SF₆ |
| Accuracy | ±2% F.S. |
| Zero/End Point Drift | ±2% F.S. / 4 h |
| Warm-up Time | 800 s |
| Operating Temperature | 5–40 °C |
| Power Supply | Rechargeable Li-ion Battery (≥4 h runtime) |
| Communication Interface | RS-232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100P |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Response Time | T90 < 15 s (NDIR channels) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100) % vol |
| O₂ | (0–25) % vol |
| C₂H₂/C₂H₄/CnHm | (0–10) % vol (optional) |
| Calorific Value | displayed in kcal/m³ and MJ/m³ |
| Resolution | 0.01 % vol |
| Linearity Error | ±1 % FS (NDIR gases), ±2 % FS (O₂, H₂) |
| Repeatability | ≤1 % |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Dimensions (L×W×H) | 412 × 152 × 294 mm |
| Weight | 9 kg |
| Power | Rechargeable Li-ion battery, external 12.6 V charger |
| Display | LCD |
| Communication | RS-232 |
| Data Storage | Internal logging with query/delete functions |
| Self-Diagnostic Capability | Real-time sensor status monitoring |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Response Time | T₉₀ < 15 s (NDIR) |
| Measurement Ranges | CO/CO₂/CH₄/H₂: (0–100)%, O₂: (0–25)%, C₂H₂/C₂H₄/CnHm*: (0–10)% (optional) |
| Resolution | 0.01% |
| Repeatability | ≤1% FS |
| Linearity Error | ±1% FS (NDIR gases), ±2% FS (O₂, H₂) |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Dimensions (L×W×H) | 412 × 152 × 294 mm |
| Weight | 9 kg |
| Power | Rechargeable Li-ion battery, external 12.6 V charger |
| Communication | RS-232 |
| Thermal Value Units | kcal/m³ & MJ/m³ (switchable) |
| Self-Diagnostic Function | Yes |
| Sample Requirements | Dust-free, moisture-free, oil-free |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100P |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Response Time | T₉₀ < 15 s (NDIR channels) |
| Measurement Ranges | CO/CO₂/CH₄/H₂: (0–100)%, O₂: (0–25)%, C₂H₂/C₂H₄/CnHm*: (0–10)% (optional) |
| Resolution | 0.01% |
| Thermal Value Output | kcal/m³ and MJ/m³ (user-selectable) |
| Flow Rate | (0.7–1.2) L/min |
| Inlet Pressure | (2–50) kPa |
| Dimensions (L×W×H) | 412 × 152 × 294 mm |
| Weight | 9 kg |
| Power | Rechargeable Li-ion battery, external 12.6 V charger |
| Interface | RS-232 |
| Display | LCD |
| Auto-diagnostic capability | Yes |
| Sample Requirements | Dust-free, dry, oil-free gas |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100P |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Response Time | T₉₀ < 15 s (NDIR channels) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100) % vol |
| O₂ | (0–25) % vol |
| C₂H₂/C₂H₄/CnHm | (0–10) % vol (optional) |
| Calorific Value | displayed in kcal/m³ or MJ/m³ |
| Resolution | 0.01 % vol |
| Linearity Error | ±1 % FS (NDIR gases), ±2 % FS (O₂, H₂) |
| Repeatability | ≤1 % FS |
| Optimal Sample Flow | (0.7–1.2) L/min |
| Inlet Pressure | (2–50) kPa |
| Dimensions (L×W×H) | 412 × 152 × 294 mm |
| Weight | 9 kg |
| Power | Internal rechargeable Li-ion battery |
| Display | LCD |
| Communication | RS-232 |
| Sample Requirements | Dust-free, moisture-free, oil-free |
| Self-diagnostic capability | Yes |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100P |
| Response Time | T90 < 15 s (NDIR) |
| Measurement Ranges | CO/CO₂/CH₄/H₂: (0–100) % vol |
| O₂ | (0–25) % vol |
| C₂H₂/C₂H₄/CnHm | (0–10) % vol (optional) |
| Resolution | 0.01 % vol |
| Detection Principles | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm) |
| Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Dimensions | 412 × 152 × 294 mm |
| Weight | 9 kg |
| Power | Rechargeable Li-ion battery, 12.6 V external charger |
| Communication | RS-232 |
| Calorific Value Units | kcal/m³ and MJ/m³ (switchable) |
| Self-Diagnostic Function | Yes |
| Sample Requirements | Dust-free, moisture-free, oil-free |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3200Plus |
| Measurement Principle | CH₄/CO₂ via NDIR |
| Range | CH₄ (0–100)% vol |
| Accuracy | CH₄/CO₂ ±2% FS |
| Power | Rechargeable 18650 Li-ion battery |
| Interface | USB, Bluetooth 4.0 |
| Display | Color LCD |
| Data Storage | Internal logging with query/delete function |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3200Plus |
| Measurement Principle | CH₄/CO₂ via NDIR |
| Range | CH₄ (0–100)% vol |
| Accuracy | CH₄/CO₂ ±2% FS |
| Power | Rechargeable 18650 Li-ion battery (replaceable) |
| Interface | USB, Bluetooth 4.0 |
| Display | Color LCD |
| Data Storage | Internal auto-log with query/delete functions |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3500 |
| Detection Principle | NDIR & Electrochemical (ECD) |
| Configuration | Fixed-mount online analyzer |
| Response Time | T90 < 15 s (NDIR channels) |
| Measured Gases | CO, CO₂, CH₄, C₃H₈, O₂, H₂S |
| Explosion Protection Rating | Ex d IIC T6 / Ex tb IIIC T80°C Db |
| Measurement Ranges | CO/CO₂/CH₄/C₃H₈: 0–100% vol |
| O₂ | 0–25% vol |
| H₂S | 0–9999 ppm |
| Accuracy | ±1% FS (NDIR gases), ±2% FS (O₂ & H₂S) |
| Repeatability | ≤2% |
| Resolution | 0.01% vol (low-range: 1 ppm for H₂S) |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Output Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Power Supply | AC 220 V, 50 Hz |
| Display | Backlit LCD |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3500 |
| Measurement Principle | NDIR & Electrochemical Detection |
| Configuration | Fixed Online Analyzer |
| Response Time | T90 < 15 s (NDIR) |
| Repeatability | ≤2% FS |
| Accuracy | ±1% FS (CO/CO₂/CH₄/C₃H₈), ±2% FS (O₂/H₂S) |
| Resolution | 0.01% vol (low-range: 1 ppm) |
| Measured Gases | CO, CO₂, CH₄, C₃H₈, O₂, H₂S |
| Flow Rate | 0.7–1.2 L/min |
| Sample Pressure | 2–50 kPa |
| Explosion Protection | Ex d II CT6 / Ex tb IIIC T80°C Db |
| Output Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Power Supply | AC 220 V, 50 Hz |
| Display | LCD |
| Preconditioning | Integrated sample conditioning system (particulate filtration, moisture removal, oil exclusion) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3500 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) & Electrochemical Detection (ECD) |
| Configuration | Fixed Online Analyzer |
| Response Time | T90 < 15 s (NDIR) |
| Repeatability | ≤2% FS |
| Measured Gases | CO, CO₂, CH₄, C₃H₈, O₂, H₂S |
| Explosion Protection Rating | Ex d IIC T6 / Ex tb IIIC T80°C Db |
| Output Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Power Supply | AC 220 V, 50 Hz |
| Sample Flow Rate | 0.7–1.2 L/min |
| Sample Pressure | 2–50 kPa |
| Display | LCD |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3500 |
| Measurement Principle | NDIR & Electrochemical Detection |
| Configuration | Fixed Online Analyzer |
| Response Time | T90 < 15 s (NDIR) |
| Repeatability | ≤2% FS |
| Accuracy | CO/CO₂/CH₄/C₃H₈: ±1% FS |
| O₂/H₂S | ±2% FS |
| Resolution | 0.01% (low-range: 1 ppm) |
| Measured Gases | CO, CO₂, CH₄, C₃H₈, O₂, H₂S |
| Measurement Ranges | CO/CO₂/CH₄/C₃H₈: (0–100)% |
| O₂ | (0–25)% |
| H₂S | (0–9999) ppm |
| Sample Flow Rate | (0.7–1.2) L/min |
| Inlet Pressure | (2–50) kPa |
| Sample Requirements | Dust-free, moisture-free, oil-free |
| Output Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Power Supply | AC 220 V, 50 Hz |
| Display | LCD |
| Explosion Protection Rating | Ex d II CT6 / Ex tb IIIC T80°C Db |
| Materials in Contact with Sample Gas | 316L stainless steel, PTFE |
| Built-in Zero Calibration | Air auto-zero pump |
| Diagnostics | Real-time sensor health monitoring |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Model | Gasboard-3500 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Gases | O₂, CO, CO₂, H₂S, CH₄ |
| Detection Ranges | O₂ (0–100% vol, down to 1 ppm), CO (0–100% vol, down to 0.1 ppm), CO₂ (0–100% vol, down to 0.1 ppm), H₂S (0–1% vol, down to 0.1 ppm), CH₄ (0–100% vol, down to 0.1 ppm) |
| Accuracy | ±0.5–2% F.S. depending on gas and range |
| Response Time | <40 s (at 2 L/min) |
| Sample Flow Rate | 0.7–1.2 L/min (optimal), up to 2 L/min |
| Explosion Protection | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Output Interfaces | RS-485, RS-232, 4–20 mA analog |
| Power Supply | AC 220 V, 50 Hz |
| Display | Integrated LCD |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9031EX |
| Measurement Principle | NDIR + Electrochemical + Thermal Conductivity (TCD/ECD) |
| Response Time | 15 s (NDIR) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100)% |
| O₂ | (0–25)% |
| C₂H₂/C₂H₄/CnHm | (0–10)% (optional) |
| Resolution | CO/CO₂/CH₄/CnHm: ±1% FS |
| H₂/O₂ | ±2% FS |
| Explosion Protection Rating | Ex d IIC T4 Gb |
| Communication Interfaces | RS-232, RS-485, (4–20) mA, Ethernet |
| Display | LCD |
| Diagnostic Features | Real-time sensor health monitoring, automatic air zeroing via built-in zero-air pump |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9031EX |
| Measurement Principle | NDIR + Electrochemical + Thermal Conductivity (TCD) |
| Response Time | 15 s (NDIR channels) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100) % vol |
| O₂ | (0–25) % vol |
| C₂H₂/C₂H₄/CnHm (non-methane hydrocarbons) | (0–10) % vol (optional) |
| Resolution | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1 % FS |
| H₂/O₂ | ±2 % FS |
| Explosion Protection | Ex d IIC T4 Gb |
| Output Interfaces | RS-232, RS-485, (4–20) mA, Ethernet |
| Auto-calibration | Built-in zero-air pump with automatic air zeroing |
| Diagnostics | Real-time sensor health monitoring and system self-diagnosis |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9031EX |
| Measurement Principle | NDIR + Electrochemical + Thermal Conductivity (TCD) |
| Response Time | 15 s (NDIR channels) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100) % vol |
| O₂ | (0–25) % vol |
| C₂H₂/C₂H₄/CnHm (hydrocarbons) | (0–10) % vol (optional) |
| Resolution | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1 % FS |
| H₂/O₂ | ±2 % FS |
| Explosion Protection | Ex d IIC T4 Gb |
| Output Interfaces | RS-232 / RS-485 / (4–20) mA / Ethernet |
| Display | LCD |
| Auto-calibration | Built-in zero-air pump with automatic air zeroing |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9050GHG |
| Instrument Type | Online CEMS |
| Measured Gases | CH₄, CO₂, CO, N₂O, O₂ |
| Detection Principle | NDIR (CH₄/CO₂/CO/N₂O), Electrochemical (O₂) |
| Range | CH₄/CO/N₂O: 0–1000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | CH₄/CO₂/CO/N₂O ≤ ±1% FS |
| Repeatability | ≤ ±1% FS |
| Resolution | CH₄/CO/N₂O: 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Response Time (T₉₀) | < 25 s |
| Linearity Error | CH₄/CO₂/CO/N₂O ≤ ±1% FS |
| Flue Gas Temp. Limit | 0–300 °C |
| Sample Line & Probe Heating | 120–180 °C |
| Enclosure Rating | IP54 |
| Dimensions (L×W×H) | 800 × 760 × 1800 mm |
| Ambient Temp. | −20 to +50 °C |
| Ambient Humidity | < 95% RH (non-condensing) |
| Power Supply | 220 V AC ±10%, >3000 W |
| Compressed Air Requirement | 0.4–0.8 MPa, oil-free, dust-free, dry |
| Max. Air Consumption | 2.2 m³/h |
| Avg. | 0.45 m³/h |
| Max. Sample Flow | 2 L/min |
| Avg. | 1.5 L/min |
| Communication Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Built-in Zero Calibration | Air auto-zero via integrated zero-air pump |
| Self-Diagnostic Capability | Real-time sensor health monitoring |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | AM4209 |
| Weight | <400 g |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
| IP Rating | IP54 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Sensitivity | 1 g/year (static), 3 g/year (dynamic) |
| Response Time | <1 s (typical) |
| Recovery Time | <5 s (typical) |
| Battery | 3.7 V DC, 2550 mAh Li-ion |
| Charging Time | 6 h |
| Standby Time | 10 h (backlight off) |
| Auto-Shutdown | 10 min |
| Compliance | EN 14624 |
| Gas Compatibility | R32, R290, R410A, R134a, R454A, R454B, R1234yf, HFO-1234yf and other A2L refrigerants |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM4210 |
| Pricing | Available Upon Request |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Gas | CH₄ |
| Measurement Range | 0–1000 ppm |
| Detection Limit | 1 ppm |
| Alarm Accuracy | ±(5 ppm + 2% of reading) |
| Resolution | 1 ppm |
| Response Time (T90) | <10 s |
| Measurement Cycle | 30 s |
| Data Upload Interval | 2 min |
| Communication | LoRaWAN / NB-IoT |
| IP Rating | IP66 |
| Operating Temperature | −20 °C to +60 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Operating Pressure | 86–106 kPa |
| Power Supply | Rechargeable Li-ion battery + optional solar panel |
| Max. Power Consumption | 2 W |
| Dimensions (L×W×H) | 186 mm × 144 mm × 417 mm |
| Weight | 6.5 kg |
| Service Life | ≥10 years |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Analyte | CH₄ |
| Measurement Range | 0–1000 ppm |
| Detection Limit | 1 ppm |
| Alarm Accuracy | ±(5 ppm + 2% of reading) |
| Resolution | 1 ppm |
| Response Time (T90) | <10 s |
| Measurement Cycle | 30 s |
| Data Upload Interval | 2 min |
| Communication | LoRaWAN / NB-IoT |
| IP Rating | IP66 |
| Operating Temperature | −20 °C to +60 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Operating Pressure | 86–106 kPa |
| Power Supply | Rechargeable Li-ion battery + optional solar panel |
| Max. Power Consumption | 2 W |
| Dimensions (L×W×H) | 186 mm × 144 mm × 417 mm |
| Weight | 6.5 kg |
| Service Life | ≥10 years |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Basic Edition |
| Instrument Type | Portable |
| Measurement Principle | Optical Transmission (Nephelometric Absorption) |
| Maximum Permissible Error | ±2.0% |
| Measuring Range | Opacity N: 0–99.99% |
| Absorption Coefficient K | 0–16 m⁻¹ |
| Resolution | N: 0.1% |
| K | 0.01 m⁻¹ |
| Power Supply | Integrated Li-ion Battery (11.1 V / 35 Ah), ≥8 h continuous operation |
| Communication | Wi-Fi & Bluetooth |
| Data Output | Digital via USB/Bluetooth/Wi-Fi |
| Optional Accessories | HD Video Recording Module, Engine RPM & Oil Temperature Sensor Inputs |