CUBIC INSTRUMENTS
Filter
Showing 211–240 of 244 results
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Online Analyzer |
| Measurement Principle | Zirconia Limiting-Current Electrochemistry + Thick-Film Catalytic Oxidation |
| Detection Range | O₂: 0–25% vol |
| COe | 0–10,000 ppm |
| Response Time | O₂: T₉₀ ≤ 10 s |
| COe | T₉₀ ≤ 20 s |
| Accuracy | O₂: ±1% FS or ±0.2% vol |
| COe | ±5% FS or ±25 ppm |
| Resolution | O₂: 0.01% vol |
| COe | 1 ppm |
| Communication | RS-485 / MODBUS RTU |
| Analog Outputs | 2 × 4–20 mA |
| Alarm Outputs | 3 configurable relay outputs |
| Environmental Operating Range | Control Unit: −40°C to +65°C |
| Sensor Unit | −40°C to +120°C |
| IP Rating | IP66 |
| Probe Materials | S316L stainless steel, Alloy 600, Alumina (Al₂O₃) |
| Flange Mounting | DN50 (customizable) |
| Probe Length | Customizable |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LMS-1000 |
| Pricing | Upon Request |
| Measurement Principle | TDLAS |
| Measurand | H₂O vapor |
| Range | 0–50 ppm to 0–6000 ppm (customizable) |
| Accuracy | ±2% FS |
| Resolution | 0.1 ppm |
| Repeatability | ≤1.5% FS |
| Explosion Protection | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Ingress Protection | IP66 |
| Ambient Temperature | −10°C to +50°C |
| Relative Humidity | 0–98% RH (non-condensing) |
| Sample Pressure | Inlet: 140–310 kPa |
| Measurement Cell | 800–1200 mbar(a) |
| Power Supply | 24 VDC ±20% or 100–240 VAC ±10%, 50/60 Hz, 10 W |
| Output Interfaces | 4–20 mA, RS-485, Modbus RTU/TCP, Ethernet |
| Display Options | Volume ratio (ppm(v)) and dew point temperature (°C/°F) |
| Dimensions (L×W×H) | 400 × 400 × 250 mm |
| Weight | 36 kg |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | LRGA-3100 |
| Price Range | USD 140,000 – 280,000 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Repeatability | ≤1% |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | LRGA-3100 |
| Spectrometer Type | Grating-Based Raman Spectrometer |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 0.01% |
| Spatial Resolution | 1 µm (lateral), 2 µm (axial) |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Repeatability | ≤1% |
| Measurement Accuracy | ≤±1% F.S. |
| Response Time | ≤10 s |
| Operating Temperature | 10–35 °C |
| Power Supply | AC 220 V / 50 Hz, <70 W |
| Dimensions (L×W×H) | 605 × 483 × 220 mm |
| Interface Options | USB, RS-232, RS-485, Ethernet |
| Measured Gases | H₂, N₂, O₂, CO, CO₂, CH₄, C₂H₂, C₂H₄, C₂H₆, C₃H₆, C₃H₈, H₂S |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LRGA-3100 |
| Price Range | USD 140,000 – 280,000 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Repeatability | ≤1% |
| Measurement Principle | Laser Raman Scattering |
| Response Time | ≤10 s |
| Accuracy | ≤±1% F.S. |
| Detection Range | 0–100% (full-scale, configurable) |
| Operating Temperature | 10–35 °C |
| Power Supply | AC 220 V / 50 Hz, <70 W |
| Interfaces | USB, RS-232, RS-485, Ethernet |
| Dimensions (L×W×H) | 605 × 483 × 220 mm |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LRGA-3100 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Repeatability | ≤1% |
| Measurement Range | 0–100% (full-scale) |
| Accuracy | ≤±1% F.S. |
| Response Time | ≤10 s |
| Operating Temperature | 10–35 °C |
| Power Supply | AC 220 V / 50 Hz, <70 W |
| Interfaces | USB, RS-232, RS-485, Ethernet |
| Dimensions (L×W×H) | 605 × 483 × 220 mm |
| Detectable Gases | H₂, N₂, O₂, CO, CO₂, CH₄, C₂H₂, C₂H₄, C₂H₆, C₃H₆, C₃H₈, H₂S |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LRGA-3100 |
| Price Range | USD 140,000–280,000 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Repeatability | ≤1% |
| Measurement Accuracy | ≤±1% F.S. |
| Response Time | ≤10 s |
| Operating Temperature | 10–35 °C |
| Power Supply | AC 220 V / 50 Hz, <70 W |
| Dimensions (L×W×H) | 605 × 483 × 220 mm |
| Communication Interfaces | USB, RS-232, RS-485, Ethernet |
| Gas Measurement Range | 0–100% (full-scale, configurable per application) |
| Detectable Gases | H₂, N₂, O₂, CO, CO₂, CH₄, C₂H₂, C₂H₄, C₂H₆, C₃H₆, C₃H₈, H₂S |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | LRGA-3200 |
| Instrument Type | Portable Raman Spectrometer |
| Spectral Repeatability | ≤1% F.S. |
| Measurement Range | 0–100% (selectable by application) |
| Accuracy | ≤±1% F.S. |
| Response Time | ≤30 s |
| Operating Temperature (Analyzer) | 10–35 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Input Voltage | 100–240 VAC, 50–60 Hz |
| Communication Interfaces | RS-232 / RS-485 / TCP/IP / USB |
| Display | Color Touchscreen |
| Probe Quantity | 1 Raman Fiber Probe |
| Probe Temp. Range | 0–200 °C |
| Probe Pressure Range | 80–4000 kPa |
| Measured Gases | H₂, N₂, O₂, CO, CO₂, CH₄, C₂H₂, C₂H₄, C₃H₆ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LRGA-3200 |
| Price Range | USD 140,000–280,000 |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Repeatability | ≤1% F.S. |
| Measurement Components | H₂, N₂, O₂, CO, CO₂, CH₄, C₂H₂, C₂H₄, C₃H₆ |
| Concentration Range | 0–100% (configurable) |
| Accuracy | ≤±1% F.S. |
| Response Time | ≤30 s |
| Input Voltage | 100–240 VAC, 50–60 Hz |
| Communication Interfaces | RS-232, RS-485, TCP/IP Ethernet, USB |
| Display | Color Touchscreen Interface |
| Probe Quantity | 1 Raman Fiber Optic Probe |
| Probe Operating Temperature | 0–200 °C |
| Probe Pressure Rating | 80–4000 kPa |
| Analyzer Ambient Operating Temperature | 10–35 °C |
| Humidity Limit | 95% RH, non-condensing |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LRGA-3200 |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Repeatability | ≤1% F.S. |
| Measurement Accuracy | ≤±1% F.S. |
| Response Time | ≤30 s |
| Operating Temperature (Analyzer) | 10–35 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Input Voltage | 100–240 VAC, 50–60 Hz |
| Communication Interfaces | RS-232 / RS-485 / TCP/IP / USB |
| Display | Color Touchscreen |
| Probe Quantity | 1 Fiber-Optic Probe |
| Probe Temperature Range | 0–200 °C |
| Probe Pressure Range | 80–4000 kPa |
| Measured Gases | H₂, N₂, O₂, CO, CO₂, CH₄, C₂H₂, C₂H₄, C₃H₆ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | LRGA-3200EX |
| Spectral Range | 0–100% (v/v) |
| Spectral Repeatability | ±1% F.S. |
| Measurement Accuracy | ±1% F.S. |
| Response Time | <1 s |
| Operating Pressure | up to 4 MPa |
| Probe Quantity | 4 |
| Fiber Optic Cable Length | 5 m (standard, customizable) |
| Enclosure Rating | IP65 |
| Explosion Protection | Ex d II C T4 Gb |
| Ambient Operating Temperature (Analyzer) | 10–35 °C |
| Probe Operating Temperature | –20 to +200 °C |
| Humidity | 0–95% RH (non-condensing) |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Max. Power Consumption | <200 W |
| Communication Interfaces | RS-232, RS-485, TCP/IP Ethernet, USB, 4–20 mA analog output |
| Dimensions (L×W×H) | 540 × 300 × 900 mm |
| Weight | 75 kg |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | LRGA-3200EX |
| Spectral Range | 0–100% (relative intensity) |
| Spectral Repeatability | ±1% F.S. |
| Measurement Accuracy | ±1% F.S. |
| Response Time | <1 s |
| Operating Pressure (probe) | up to 4 MPa |
| Probe Operating Temperature | −20 to 200 °C |
| Analyzer Operating Temperature | 10–35 °C |
| Humidity | 0–95% RH (non-condensing) |
| Power Input | 100–240 VAC, 50–60 Hz |
| Max. Power Consumption | <200 W |
| Enclosure Rating | IP65 |
| Explosion Protection | Ex d II C T4 Gb |
| Probe Quantity | 4 |
| Standard Fiber Length | 5 m (customizable) |
| Dimensions (L×W×H) | 540 × 300 × 900 mm |
| Weight | 75 kg |
| Communication Interfaces | RS-232, RS-485, TCP/IP Ethernet, USB, 4–20 mA analog outputs |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | LRGA-3200EX |
| Type | Online Raman Spectrometer |
| Spectral Range | 0–100% (v/v) |
| Spectral Repeatability | 1% F.S. |
| Accuracy | ±1% F.S. |
| Response Time | <1 s |
| Operating Pressure | up to 4 MPa |
| Probe Quantity | 4 |
| Fiber Optic Cable Length | 5 m (standard, customizable) |
| Enclosure Rating | IP65 |
| Explosion Protection | Ex d II C T4 Gb |
| Ambient Operating Temperature (Analyzer) | 10–35 °C |
| Probe Operating Temperature | –20–200 °C |
| Humidity | 0–95% RH (non-condensing) |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Max. Power Consumption | <200 W |
| Communication Interfaces | RS-232, RS-485, TCP/IP Ethernet, USB, 4–20 mA analog output |
| Dimensions (L×W×H) | 540 × 300 × 900 mm |
| Weight | 75 kg |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | LRGA-3200EX |
| Type | Online Raman Spectrometer |
| Spectral Range | 0–100% (v/v) |
| Spectral Repeatability | 1% F.S. |
| Measurement Accuracy | ±1% F.S. |
| Response Time | <1 s |
| Operating Pressure (Probe) | Up to 4 MPa |
| Probe Temperature Range | –20 °C to +200 °C |
| Analyzer Ambient Temp. | 10–35 °C |
| Humidity | 0–95% RH, non-condensing |
| Power Input | 100–240 VAC, 50–60 Hz |
| Max. Power Consumption | <200 W |
| Communication Interfaces | RS-232 / RS-485 / TCP/IP / USB / 4–20 mA analog output |
| Enclosure Rating | IP65 |
| Explosion Protection | Ex d II C T4 Gb |
| Dimensions (L×W×H) | 540 × 300 × 900 mm |
| Weight | 75 kg |
| Standard Fiber Optic Cable Length | 5 m |
| Number of Probes | 4 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | LRGA-3200EX |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 0.01% |
| Spatial Resolution | 1 µm (lateral), 2 µm (axial) |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Repeatability | 1% F.S. |
| Measurement Accuracy | ±1% F.S. |
| Operating Pressure | up to 4 MPa |
| Explosion Protection | Ex d II C T4 Gb |
| IP Rating | IP65 |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Max Power Consumption | <200 W |
| Communication Interfaces | RS-232, RS-485, TCP/IP, USB, 4–20 mA analog output |
| Probe Quantity | 4 |
| Standard Fiber Length | 5 m (customizable) |
| Dimensions (L×W×H) | 540 × 300 × 900 mm |
| Weight | 75 kg |
| Ambient Operating Temperature (Analyzer) | 10–35 °C |
| Probe/Process Temperature | −20 to +200 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LRGA-6000 |
| Price Range | USD 140,000–280,000 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 0.01% |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Repeatability | Not Specified |
| Spatial Resolution | Not Applicable |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LRGA-6000 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 0.01% |
| Spatial Resolution | 1 µm (lateral), 2 µm (axial) |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Reproducibility | ≤1% (dependent on configured measurement range) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | LRGA-6000 |
| Spectrometer Type | Grating-Based Raman Spectrometer |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 0.01% |
| Spatial Resolution | 1 µm (lateral), 2 µm (axial) |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Repeatability | ≤1% (dependent on configured measurement range) |
| Measurement Range | 0–10% to 0–100% (gas concentration, full-scale) |
| Linearity Error | ≤±1% F.S. |
| Response Time | ≤30 s |
| Dimensions | 1000 × 800 × 1780 mm |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LRGA-6000 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 0.01% |
| Spatial Resolution | 1 µm (lateral), 2 µm (axial) |
| Minimum Wavenumber Shift | 10 cm⁻¹ |
| Spectral Repeatability | ≤1% (dependent on configured concentration range) |
| Measurement Range | 0–10% to 0–100% (gas volume %) |
| Linearity Error | ≤±1% FS |
| Response Time | ≤30 s |
| Dimensions | 1000 × 800 × 1780 mm |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | LRGA-6000 |
| Spectrometer Type | Grating-based Raman Spectrometer |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 0.01% |
| Spatial Resolution | 1 µm (lateral), 2 µm (axial) |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Repeatability | ≤1% (dependent on configured measurement range) |
| Measurement Range | 0–10% to 0–100% (gas concentration, full-scale) |
| Linearity Error | ≤±1% F.S. |
| Response Time | ≤30 s |
| Dimensions | 1000 × 800 × 1780 mm |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | LRGA-6000 |
| Spectrometer Type | Grating-based Raman Spectrometer |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 0.01% |
| Spatial Resolution | Lateral 1 µm, Axial 2 µm |
| Minimum Wavenumber Shift | 10 cm⁻¹ |
| Spectral Repeatability | ≤1% (dependent on configured measurement range) |
| Measurement Range | 0–10% to 0–100% (user-selectable per gas) |
| Linearity Error | ≤±1% FS |
| Response Time | ≤30 s |
| Dimensions | 1000 × 800 × 1780 mm |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | CUBIC-EMX-4N |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Detection Principle | Integrated TDLAS + UV-DOAS + GFC Infrared Spectroscopy |
| Measured Components | NH₃, NO, NO₂, N₂O |
| Measurement Range (NH₃) | 0–100 ppm (low), 0–5000 ppm (high) |
| Measurement Range (NO) | 0–200 ppm (low), 0–5000 ppm (high) |
| Measurement Range (NO₂) | 0–200 ppm (low), 0–3000 ppm (high) |
| Measurement Range (N₂O) | 0–200 ppm (low), 0–5000 ppm (high) |
| Sample Gas Line Temperature | 113 °C ± 6 °C |
| Sample Flow Rate | 8.0 L/min ± 1.0 L/min |
| Operating Ambient Temperature | 5–40 °C |
| Operating Relative Humidity | ≤80 % RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Not Applicable |
| Price | Upon Request |
| Linearity Error | ±2% F.S. |
| Repeatability | ±2% F.S. |
| Response Time (T90) | <10 s |
| Measurement Ranges | CO₂: 0–5,000 ppm |
| CO | 0–30% vol |
| CH₄ | 0–10% vol |
| Resolution | CO₂: 0.1 ppm |
| CO | 0.01% vol |
| CH₄ | 0.01% vol |
| Accuracy | ±2% F.S. for all gases |
| Stability | ≤±2% per month |
| Response Time (T90) | ≤30 s |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Portable Engine Emission Analyzer |
| Instrument Type | Portable |
| Detection Principle | UV-DOAS / NDUV / NDIR |
| Max. Permissible Error | NO/NO₂: ±2% rel. or ±25 ppm abs. |
| CO₂ (0–16%) | ±3% rel. or ±0.3% abs., (16–18%): ±5% rel. |
| Opacity (K) | ±2.0% rel. |
| Measurement Range | NO: 0–4000 ppm |
| NO₂ | 0–1000 ppm |
| CO₂ | 0–18% vol |
| K | 0–16 m⁻¹ |
| Resolution | NO/NO₂: 1 ppm |
| CO₂ | 0.1% vol |
| K | 0.01 m⁻¹ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Species | CH₄ |
| Methane Concentration Range | 0.01%–100% vol |
| Emission Flux Range | 0.01–13 kg/h |
| Measurement Accuracy | ±5% of reading |
| Sampling Flow Rate | up to 400 L/min |
| Battery Runtime | >8 h |
| Charging Time | 10 h |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Standalone Version |
| Instrument Type | Portable |
| Measurement Principle | Optical Transmission (Nephelometric Absorption) |
| Maximum Permissible Error | ±2.0% |
| Display | Integrated LCD Monitor |
| Sampling Probe | Fixed-length, heat-resistant stainless steel probe |
| Optional | Built-in thermal printer |
| Compliance | GB 3847–2018, GB 36886–2018 |
| Electrical Interface | RS-232 / RS-485 digital output & print port |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Measurement Range | Opacity N: 0–99.99% |
| Absorption Coefficient K | 0–16 m⁻¹ |
| Resolution | N: 0.1% |
| K | 0.01 m⁻¹ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Standard Edition |
| Instrument Type | Portable |
| Measurement Principle | Optical Transmission (Filter-Based Nephelometry) |
| Max. Permissible Error | ±2.0% for Opacity (N) and Absorption Coefficient (K) |
| Opacity Range | 0–99.99% (Resolution: 0.1%) |
| K-Value Range | 0–16 m⁻¹ (Resolution: 0.01 m⁻¹) |
| Engine Speed | 400–6000 rpm (Resolution: 1 rpm |
| Accuracy | ±10 rpm or ±1%) |
| Ambient Temperature | −20–60 °C (Resolution: 0.1 °C |
| Accuracy | ±4% rel. or ±0.5 °C abs.) |
| Relative Humidity | 5–99% RH (Resolution: 0.1% RH |
| Accuracy | ±5% rel. or ±3% RH abs.) |
| Atmospheric Pressure | 70–106 kPa (Resolution: 0.01 kPa |
| Accuracy | ±5% rel. or ±2 kPa abs.) |
| Oil Temperature (optional) | 0–200 °C (Resolution: 1 °C |
| Accuracy | ±5 °C abs.) |
| Key | Brand: CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Explosion Protection Rating | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Gases | O₂, CO, CO₂, H₂S, CH₄ |
| Response Time | <40 s (at 2 L/min) |
| Sample Flow Rate | 0.7–1.2 L/min (optimal), up to 2 L/min |
| Output Interfaces | RS-485, RS-232, 4–20 mA |
| Power Supply | AC 220 V, 50 Hz |
| Display | Integrated LCD |
| Built-in Zeroing | Air auto-zero pump |
| Diagnostic Capability | Real-time sensor self-diagnosis |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Instrument Type | Online Fixed-Position Analyzer |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Maximum Permissible Error | ≤±2.0% of Reading Span (RS) or ≤±0.3% of Full Scale (FS) |
| Measured Gases | NH₃, N₂O |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Minimum Range | 0–50 ppm (NH₃), 0–100 ppm (N₂O) |
| Maximum Range | 0–2000 ppm (both) |
| Response Time (T₁₀–₉₀) | <2.5 s |
| Linearity | R² ≥ 0.998 |
| Operating Environment | 5–40 °C, ≤80% RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Type | Online Dew Point Analyzer |
| Accuracy | ±2% F.S. |
| Repeatability | ≤1.5% F.S. |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measurement Range | 0–6000 ppmv H₂O |
| Resolution | 0.1 ppmv |
| Explosion Protection | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Ingress Protection | IP66 |
| Operating Temperature | −10°C to +50°C |
| Operating Humidity | 0–98% RH (non-condensing) |
| Sample Pressure | Inlet: 140–310 kPa |
| Measurement Cell | 800–1200 mbara |
| Power Supply | 24 VDC ±20% or 100–240 VAC ±10%, 50/60 Hz, 10 W |
| Communication Interfaces | RS-485, 4–20 mA, Modbus RTU/TCP, Ethernet |
| Dimensions (L×W×H) | 400 × 400 × 250 mm |
| Weight | 36 kg |