Cytiva
Filter
Showing 31–60 of 86 results
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA™ start |
| Purification Principle | Affinity Chromatography (AC) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.5–5 mL/min |
| Flow Accuracy | ±15% at ≤1 mL/min |
| Flow Precision | ±15% at ≤1 mL/min |
| Detection | UV Monitor (280 nm single-wavelength), Conductivity Monitor |
| Pressure Range | 0–0.5 MPa |
| Conductivity Range | 0–300 mS/cm |
| Solvent Compatibility | Compatible with in-place cleaning using 1 mol/L NaOH and 2 mol/L NaCl for ≥3 hours per day |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ÄKTA™ start |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Pack of 12 SU Allegro Needles – 0.8 mm Luer |
| Sterilization | Gamma Irradiation (≤50 kGy) or Steam Autoclaving (130°C, 75 min) |
| Material | PEEK shaft with stainless steel reinforcement, polypropylene hub, silicone O-ring |
| Fluid Path | USP Class VI compliant |
| Cleanroom Manufacturing | ISO Class 8 |
| Quality System | ISO 9001 certified |
| Regulatory Compliance | USP <788>, <85>, <661.1>, <1031>, FDA 21 CFR Part 11–ready documentation support |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham ImageQuant 800 |
| Imaging Type | Chemiluminescence Gel Imager |
| CCD Resolution | 8.3 MP |
| Lens | Fujinon F0.74 |
| LED Channels | RGB, NIR-short, NIR-long, UV, Side-reflected white light, Transmitted white light |
| GxP Compliance Module | Optional FDA 21 CFR Part 11 / EU GMP Annex 11 Ready |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham ImageQuant 500 |
| Imaging Type | Chemiluminescence |
| CCD Resolution | 8.3 MP |
| Dynamic Range | 4.8 decades |
| Lens Aperture | f/0.14 (Fujifilm) |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon IP |
| Dynamic Range | >5 decades |
| Scan Area | 40 × 46 cm |
| Imaging Modes | Phosphor Imaging, Fluorescence (RGB), Near-Infrared (NIR), Optical Density (OD) |
| Detector Type | High-Sensitivity PMT-based Scanning System |
| Lens | Fujifilm Precision Optics |
| Compliance | Supports IQ/OQ Documentation, GLP/GMP-Ready Data Acquisition |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon NIR / NIR+ |
| Instrument Type | Multicolor Fluorescent Gel Imaging System |
| Detection Principle | Confocal Laser Scanning with Dual-NIR Fluorescence Excitation and Emission Filtering |
| Laser Wavelengths | 685 nm, 785 nm |
| Emission Filters | IRshort 720BP20, IRlong 825BP30 |
| Scan Modes | Automatic, Semi-Automatic, Manual |
| Sample Formats | SDS-PAGE gels, agarose gels, nitrocellulose/PVDF membranes, microplates, Petri dishes, glass slides, tissue sections |
| Detector | Enhanced Photomultiplier Tube (PMT) optimized for NIR spectral range |
| Dynamic Range | >4 orders of magnitude (log-linear response) |
| Spatial Resolution | ≤50 µm (pixel size adjustable) |
| Software Platform | ImageQuant TL with GLP-compliant audit trail and 21 CFR Part 11 optional modules |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon RGB |
| Imaging Modes | Multicolor Fluorescence (RGB), Dual-Channel Near-Infrared (NIR), Phosphor Imaging, Optical Density (OD) |
| Pixel Resolution | Down to 10 µm |
| Scan Area | Up to 40 × 46 cm (Typhoon 5/RGB) |
| Dynamic Range | >5 orders of magnitude |
| Detection Sensitivity | As low as 3 pg protein (fluorescently labeled) |
| Laser Configuration | 5-laser platform (Typhoon 5) |
| Detector Type | High-gain Photomultiplier Tubes (PMTs) |
| Upgrade Path | Field-upgradable across models |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | AxiChrom 50/300 |
| Column Internal Diameter | 50 mm |
| Column Height (Max. Packing Height) | 300 mm |
| Construction Material | USP Class VI–compliant polymers, animal-free origin, FDA 21 CFR 177 compliant |
| Regulatory Support | IQ/OQ documentation packages available |
| Sterilization | Steam-in-place (SIP) compatible |
| Column Operation | Low-pressure preparative chromatography (≤ 5 bar typical) |
| Packing Method | Automated slurry packing via ÄKTA systems and UNICORN software |
| Scale-up Platform | Process development to GMP manufacturing (50–200 mm i.d. range) |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Biacore 1K SPR System |
| Configuration | Single-injection needle, six-flow-cell platform |
| Regulatory Readiness | Optional GxP-compliant software package (21 CFR Part 11 audit trail enabled) |
| Software | Biacore Insight™ v3.x |
| Service Support | OptiRun™ lifecycle service program |
| Upgrade Path | Compatible with Biacore 1K+ expansion module for enhanced ligand multiplexing and sample throughput |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Biacore 1K+ SPR System |
| Channel Configuration | Single-needle, 6-flow cell architecture |
| Sample Capacity | Dual 96-well microplate support + dual reagent racks |
| Buffer Selection | Integrated automated buffer selector |
| Temperature Control | Precise thermostatic sample compartment |
| Software Platform | Biacore Insight™ with FDA 21 CFR Part 11-compliant audit trail and GLP/GMP-ready data management |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Biacore 1S+ SPR System |
| Instrument Type | Surface Plasmon Resonance (SPR) |
| Flow Cell Configuration | Six parallel flow cells |
| Detection Range | fM to mM |
| Sample Capacity | Up to two 96-well or 384-well microplates plus 21–43 additional sample positions |
| Analysis Time per Cycle | 2–15 minutes |
| Temperature Control Range | 4–37°C |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Biacore 8K+ SPR System |
| Instrument Type | Surface Plasmon Resonance (SPR) |
| Channel Configuration | Multi-channel (8 sample needles, 16 simultaneous interaction channels) |
| Detection Range | fM to mM |
| Sample Capacity | Up to 4,608 samples (12 × 384-well plates or 24 × 96-well plates) |
| Analysis Time per Cycle | 2–15 minutes |
| Temperature Control Range | 4°C to 40°C |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Biacore S200 |
| Instrument Type | Label-Free Molecular Interaction Analyzer |
| Application Focus | Fragment-Based Drug Discovery (FBDD), Kinetic & Affinity Analysis, Epitope Mapping, Competitive Binding Assays |
| Regulatory Context | Designed for GLP-compliant workflows |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Biacore X100 |
| Instrument Type | Surface Plasmon Resonance (SPR) |
| Channel Configuration | Multi-channel |
| Detection Range | pM–mM |
| Sample Capacity | 15 samples per run |
| Analysis Time | 2–15 minutes per interaction cycle |
| Temperature Control Range | 4–40 °C |
| Brand | Cytiva |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | BioProcess IC 1.5-inch |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | BioProcess pcc 1/2" |
| Control Software | UNICORN™ or DeltaV™ |
| Column Configuration | 3-column (3C) or 4-column (4C) |
| Application | Continuous downstream purification of therapeutic proteins |
| Compliance Framework | Supports FDA 21 CFR Part 11, GMP, and GLP audit trails via software configuration |
| Service Support | OptiRun™ lifecycle service packages available |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioProcess Resin Mixer |
| Pricing | Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | EPS |
| Application | Dedicated Power Supply for Electrophoresis Systems |
| Output Modes | Constant Voltage, Constant Current, Constant Power |
| Compliance | CE, UL 61010-1, IEC 61010-2-040 |
| Safety Features | Overload Protection, Short-Circuit Protection, Auto-Restart After Power Interruption |
| Power Range | EPS 301 (1–80 W) |
| Voltage Range | EPS 301 (5–300 V DC) |
| Current Range | EPS 301 (10–400 mA) |
| Time Programming | EPS 301 (00.01–23.59 h or OFF) |
| EPS 3501XL (00 | 01–500 h) |
| Resolution | Voltage (1 V), Current (EPS 301: 1 mA |
| EPS 3501XL | 1 µA to 1 mA depending on range), Time (1 min) |
| Accuracy | Voltage (±4% ±2 V for EPS 301 |
| Timer Accuracy | ±0.1% ±1 min (EPS 301) |
| ±0.1% ±1 min (≤99 | 59 h) / ±0.1% ±10 min (100–500 h) for EPS 3501XL |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Ettan 2D DIGE |
| Instrument Type | Two-Dimensional Fluorescent Differential Gel Electrophoresis System |
| Core Components | Ettan IPGphor 3 Isoelectric Focusing Unit, Amersham DIGE Unit LF24 Vertical SDS-PAGE Electrophoresis System, Typhoon Laser Scanner with Multi-Channel Fluorescence Detection, CyDye DIGE Fluorophores (Cy2/Cy3/Cy5), Melanie 9 Image Analysis Software |
| Sample Capacity | Up to 3 samples co-separated per 2D gel |
| Sensitivity | Quantitative detection of ≤10% protein abundance change with ≥95% statistical confidence |
| Minimum Sample Requirement | As low as 5 µg total protein per sample |
| Compliance | Designed for GLP-compliant proteomics workflows |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Ettan IPGphor 3 |
| Instrument Type | Isoelectric Focusing (IEF) Electrophoresis System |
| Gel Format Compatibility | IPG strips (7 cm, 11 cm, 13 cm, 18 cm, 24 cm) |
| Sample Capacity | Up to 12 IPG strips per run (with standard manifold) or single IPG strip with Ettan IPGphor Manifold |
| Voltage Range | 0–10,000 V (programmable ramping and stepwise control) |
| Current Limit | 0–100 µA–100 mA (auto-adjusting) |
| Temperature Control Range | 15–30 °C (±0.1 °C stability) |
| Dimensions (W×D×H) | 278 × 160 × 471 mm |
| On-device Method Storage | 10 methods (9 steps each) |
| PC Software Control | Ettan IPGphor 3 Control Software (supports up to 4 instruments simultaneously) |
| Data Logging | Real-time voltage, current, and kV·h monitoring with graphical export |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FineLINE Pilot 35 |
| Price | Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | iCELLis™ Nano Bioreactor System |
| Temperature Range | Double-jacketed with TCU – 20–40 °C |
| Surface Area Range (iCELLis™ 500+) | 60–500 m² |
| Surface Area Range (iCELLis™ Nano) | 0.53–4 m² |
| Configuration | Single-use, integrated fixed-bed bioreactor |
| Operating Modes | Batch and perfusion |
| Compliance | Designed to support GMP-compliant manufacturing |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | NanoAssemblr™ Ignite™ Instrument |
| Flow Rate Range | 20–200 mL/min |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Instrument Type | High-Throughput |
| Synthesis Scale Range | 10–1800 µmol |
| Explosion-Proof Design | Yes |
| Industrial-Grade Components | Yes |
| Regulatory Compliance | GMP-Ready, Supports FDA 21 CFR Part 11 & EU Annex 11 |
| Software Platform | UNICORN® v7.x or later |
| Scalability | Linear lab-to-commercial scale-up |
| Annual Production Capacity | Up to hundreds of kilograms (kg/yr), extendable to metric tons under continuous operation |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | OligoProcess™ |
| Synthesis Scale | 10–1800 mmol per run |
| Regulatory Compliance | FDA 21 CFR Part 11, GMP-ready architecture |
| Software Platform | UNICORN 7.x or later |
| Column Technology | Flow-through synthesis columns (compatible with ÄKTA oligopilot plus and OligoPilot 400) |
| Construction | Industrial-grade, explosion-proof certified components |
| Application Scope | Clinical-phase development through commercial-scale cGMP manufacturing |
| Brand | Cytiva |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | RTP XL 100 L, Polypropylene Construction |
| Capacity Options | 100 L, 200 L, 500 L, 1000 L |
| Wheel Configuration | Full-rotation locking casters |
| Bag Integration | Compatible with ReadyCircuit single-use bag assemblies |
| Drain Plate | Removable, accommodates capsule filters up to 72.6 cm (30 in) |
| Ergonomic Features | Hinged access door (500/1000 L models), low-profile fill/drain ports, integrated volume scale indicators |
| Material Compliance | USP Class VI polypropylene, ISO 10993-compliant contact surfaces |
| Sterility Assurance | Designed for gamma-irradiated single-use bag integration under aseptic conditions |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | ReadyToProcess WAVE 25 |
| Maximum Working Volume | 25 L |
| Drive Mechanism | Motorized Rocking Platform with Adjustable Speed, Angle, and Motion Profile |
| Temperature Control | Integrated Heated Tray with Dual Independent PID Loops (Dual-Mode Operation) |
| Weight Measurement | Built-in Load Cells with Auto-Calibration Capability |
| Gas Transfer | Passive O₂/CO₂ Exchange via Sterile Vent Filters (Heated Exhaust Filter Included) |
| Data Storage | Dual Mirrored SSDs + UNICORN Database Integration |
| Communication Protocol | OPC UA Compliant |
| Compliance | Designed for GMP Environment |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | WAVE 20/50 |
| Maximum Working Volume | 25 L |
| Tray Sizes | 5 L / 10 L / 25 L |
| Brand | Cytiva |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | GE ReadyToProcess WAVE 25 Bioreactor |
| Temperature Range | 6–60 °C |
| Working Volume Range | 10–2000 L |
| Number of Vessels | 1 |
| Construction Material | Stainless Steel |
| Sterilization Method | Single-Use Bioreactor System |