Cytiva
Filter
Showing 1–30 of 95 results
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA oligosynt™ |
| Type | Fully Automated Solid-Phase Oligonucleotide Synthesizer |
| Synthesis Scale Range | 40 nmol to 1 µmol |
| Reagent Delivery Precision | ≤2% RSD |
| System Footprint | 600 × 650 × 700 mm (W × D × H) |
| Integrated Sensor Suite | Pressure, Mass Flow, Temperature, UV Absorbance, Conductivity |
| Compliance | Designed for GLP/GMP-aligned process development environments |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | AKTA pcc |
| Purification Principle | Affinity Chromatography (AC) |
| Detector Type | Xenon Lamp UV-Vis Detector |
| Detection Capabilities | UV Absorbance (280 nm, 254 nm), Conductivity, pH, Temperature, Pressure |
| Column Positions | 3 or 4 |
| Post-Loading Wash (PLW) Functionality | Yes |
| Regulatory Compliance Support | FDA 21 CFR Part 11, EU Annex 11, GLP/GMP-ready software architecture |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | 28-9062-61 |
| Configuration | Pre-sterilized, disposable flow path system |
| Flow Rate Range | 50 mL/min to 510 L/hr |
| Column Diameter Compatibility | 70 mm – 450 mm |
| Regulatory Compliance | USP Class VI biocompatible materials |
| Manufacturing Environment | ISO 8 cleanroom packaging |
| Documentation | Full traceability, batch-specific validation dossiers, GMP-aligned support files |
| Brand | Cytiva |
|---|---|
| Origin | United Kingdom |
| Model | Amersham DIGE Unit LF24 |
| Gel Dimensions | 255 × 186 × 1 mm |
| External Dimensions | 277 × 217 × 7 mm |
| Max. Simultaneous Gels (Electrophoresis) | 2 |
| Max. Simultaneous Gels (Transfer) | 2 |
| Max. Voltage | 800 V |
| Max. Current | 400 mA |
| Max. Power | 100 W |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | Amersham Imager 600 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 5.8 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| CCD Sensor Size | 15.6 × 23.4 mm |
| Detection Sensitivity | ≥0.02 ng protein, ≥0.02 ng DNA |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens Focal Length | 8–48 mm |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | Amersham Typhoon NIR |
| Excitation Wavelengths | 685 nm & 785 nm (integrated diode lasers) |
| Detection | Dual PMT detectors |
| Dynamic Range | 5 decades |
| Image Depth | 16-bit |
| Scan Area | 40 × 46 cm |
| Pixel Resolution Options | 10, 25, 50, 100, 200 µm (standard) |
| Standard Filters | IRshort 720BP20, IRlong 825BP30 |
| Optional Filters | Cy2 LPB515, Cy3 LPG550, Cy5 LPR660, IP 390BP, Cy2 525BP20, Cy3 570BP20, Cy5 670BP30 |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | AxiChrom Master |
| Instrument Type | Dynamic Axial Compression System |
| Regulatory Compliance | 21 CFR Part 11 compliant software |
| Column Diameter Range | 300–2000 mm |
| Operation Mode | Automated column packing with preloaded and user-editable packing methods |
| Brand | Cytiva |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Membrane Area Compatibility | 0.1–2.5 m² (cassette & hollow-fiber modules) |
| Predefined Process Programs | UF Production, Normalized Water Permeability (NWP), Clean-in-Place (CIP), Water Rinse, Alkaline Hold |
| Regulatory Alignment | Designed to support GMP, FDA 21 CFR Part 11, and EU Annex 11 compliance requirements |
| Software Architecture | Embedded control with audit trail, user access levels, and electronic signature capability |
| System Flexibility | Modular configuration for lab-scale development, pilot-scale process validation, and small-batch cGMP manufacturing |
| Brand | Cytiva |
|---|---|
| Origin | Manufactured in China under Cytiva’s global quality system |
| Manufacturer Type | Authorized Distributor |
| Model | Agile flux TFF Systems |
| Pricing | Available upon request |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | 28-9308-42 |
| Application | Preparative Chromatography for Protein Purification |
| Flow Rate Range | Up to 25 mL/min |
| Max System Pressure | 20 MPa (200 bar) |
| UV Detection Range | –6 to +6 AU |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| pH Measurement Range | 0–14, Accuracy ±0.1 pH (pH 2–12) |
| Temperature Monitoring Range | 0–99 °C, Accuracy ±1.5 °C (4–45 °C) |
| Fraction Collection Volume | 0.1–50 mL |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Operating Temperature | 4–35 °C |
| Relative Humidity | 20–95%, non-condensing |
| Power Consumption | 1100 W |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | AKTA avant |
| Purification Principle | Affinity Chromatography (AC) |
| Detector Type | Xenon Lamp UV-Vis Detector |
| Detection Range | UV 190–700 nm |
| System Pressure Rating | Up to 20 MPa |
| Flow Rate Range | 0.001–20 mL/min (AKTA avant 25) |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| UV Absorbance Range | –6 to +6 AU |
| pH Measurement Range | 0–14 pH units (±0.1 pH accuracy, pH 2–12) |
| Temperature Control Range | 4–35 °C |
| Column Pressure Differential Monitoring | Dual integrated pressure sensors (pre- and post-column) |
| Buffer Preparation | Integrated BufferPro with quaternary valve, 26 preconfigured buffer recipes, real-time composition display |
| Software Platform | UNICORN 6 with FDA 21 CFR Part 11 compliance, audit trail, electronic signatures, role-based access control |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | AKTA avant |
| Flow Rate Options | 25 mL/min (AKTA avant 25) or 150 mL/min (AKTA avant 150) |
| Pressure Rating | Up to 20 MPa (200 bar) |
| Software | UNICORN 7.x or later |
| Column Tracking | RFID-enabled column recognition |
| Fraction Collector | Integrated Peltier-cooled (4–15 °C) |
| Buffer Preparation | BufferPro™ automated in-line mixing |
| Compliance | Supports 21 CFR Part 11-compliant configurations with audit trail, electronic signatures, and user access control |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | AKTA crossflow |
| Application Range | 25 mL – 50 L |
| Pump Flow Rate (Feed) | Up to 600 mL/min |
| Pump Flow Rate (Permeate/Retentate) | Up to 200 mL/min |
| Membrane Area Capacity | Up to 0.1 m² |
| Control Software | UNICORN™ v7.x or later |
| Compliance | FDA 21 CFR Part 11, USP <1211>, ISO 13485, GMP/GLP-ready |
| Sanitization | Validated NaOH (1 M) CIP, ≥6-log reduction in microbial challenge testing |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA flux 6 |
| Configuration | Semi-automated TFF platform |
| Application Scope | Concentration, diafiltration, cell harvest & clarification |
| Membrane Compatibility | Hollow-fiber modules & cassette-type membrane packs |
| Operating Volume Range | 50 mL – 6 L |
| Control Interface | Integrated touchscreen with real-time parameter monitoring |
| Data Logging | Onboard process recording (time-stamped, user-ID traceable) |
| Regulatory Support | Compliant with FDA 21 CFR Part 11 audit trail requirements for GMP-relevant workflows |
| Service Framework | OptiRun lifecycle support program |
| Change Notification | Web-based Change Control Notification (CCN) service |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA flux 6 |
| Application Scope | Process Development & Small-Scale Production |
| Control Mode | Automated Endpoint & Constant Retentate Volume (CRV) |
| Data Handling | Real-Time Logging with Audit-Trail-Capable Software |
| Regulatory Compliance | Designed for GMP Environments |
| Installation & Qualification | IQ/OQ Support Available by Certified Engineers |
| User Interface | Integrated Touchscreen HMI |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | AKTA flux |
| Application Scope | Research, Filter Screening, Process Development, and Small-Scale Production |
| Control Mode | Semi-Automated with Endpoint & Constant Retentate Volume (CRV) Control |
| User Interface | Touchscreen HMI with Real-Time Process Monitoring & Data Logging |
| Membrane Compatibility | Hollow-Fiber Modules and Cassettes |
| Regulatory Support | IQ/OQ Documentation Available via Fast Trak Validation™ Service |
| Compliance Context | Designed to support GLP/GMP environments |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA flux s |
| Application Scope | Research & Membrane Screening |
| Control Mode | Automated Endpoint Control, Constant Retentate Volume (CRV) Mode |
| User Interface | 7-inch High-Resolution Touchscreen with Real-Time Process Monitoring |
| Data Handling | Onboard Logging (CSV Export), Audit-Trail-Ready Event History |
| Compliance Context | Designed for GLP-compliant workflows |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA go Protein Purification System |
| Flow Rate | 0.01–25 mL/min |
| Max Operating Pressure | 5 MPa |
| UV Wavelength | 280 nm |
| Conductivity Range | 0.01–999.99 mS/cm |
| pH Range (optional) | 0–14 |
| Path Length (flow cell) | 2 mm (optional 5 mm) |
| Dimensions (W×D×H) | 335 × 464 × 482 mm |
| Weight | 27 kg |
| Power Consumption (typical) | 100 W |
| Safety Certifications | 2006/42/EC (MD), 2004/108/EC (EMC), 1999/5/EC (R&TTE) |
| IP Rating | IP21 |
| Tubing ID | 0.5 mm |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ÄKTA oligosynt™ |
| Price Range | USD 14,000 – 140,000 (est.) |
| Principle | Electrochemical Phosphoramidite Synthesis |
| Type | High-Throughput Benchtop Synthesizer |
| Synthesis Scale | 10 µmol – 12 mmol |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA pcc |
| Application | Periodic Counter-Current Chromatography (PCC) for Protein Purification |
| Software | UNICORN™ Control Software |
| Configuration Options | 3-Column (3C) or 4-Column (4C) Setup |
| Regulatory Support | Change Control Notification (CCN) Service |
| Service Offering | OptiRun™ Lifecycle Support Program |
| Compliance Context | Designed for GMP-aligned process development and scale-up per ICH Q5, Q8, and Q9 principles |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA pilot 600S |
| Application Scope | Non-GMP Process Development & Scale-up |
| Column ID Range | 26–200 mm |
| Flow Rate Range | 0.01–600 mL/min |
| Max Pressure | 20 MPa (200 bar) |
| System Architecture | Modular Benchtop Platform |
| Software Platform | UNICORN 7.x or later |
| Regulatory Support | Audit Trail, Electronic Signatures, User Access Levels (GMP-compliant configuration available in ÄKTA pilot 600R variant) |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | AKTA pilot 600S / AKTA pilot 600R |
| Application Scope | GMP and non-GMP process development, scale-up studies, and small-batch cGMP manufacturing |
| Column ID Range | 26–200 mm |
| Pump Flow Rate Range | 0.01–600 mL/min |
| Maximum System Pressure | 20 MPa (200 bar) |
| Gradient Accuracy | ≤ ±0.5% RSD |
| Software Platform | UNICORN 7.x or later |
| Compliance | Designed to support 21 CFR Part 11, GAMP 5, and GLP/GMP documentation requirements |
| Modular Architecture | Yes |
| Prepacked Column Compatibility | ReadyToProcess™ 1 L and 2.5 L columns |
| AxiChrom™ Integration | Native via SmartPacking port |
| Footprint | Compact benchtop or ReadyKart-mountable design |
| Weight | < 90 kg |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | 29-0182-24 |
| Purification Principle | Affinity Chromatography (AC) |
| Detector Type | Xenon Lamp UV-Vis Detector |
| Absorbance Range | ±6 AU |
| Weight | 48 kg |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA pure™ 150T |
| Maximum Flow Rate | 150 mL/min |
| UV Detection Wavelengths | Fixed at 260 nm and 280 nm |
| Software Platform | UNICORN 7 |
| Column Switching Capacity | Up to 10 columns via optional column selection valve |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA pure™ T Chromatography System |
| Purification Principle | Gel Filtration Chromatography (GFC) |
| Gradient Type | Linear Gradient |
| Detectors | Dual-wavelength UV monitor (260 & 280 nm), Conductivity monitor, pH monitor |
| Flow Rate Range | ÄKTA pure™ 25T: 0.001–25 mL/min (up to 50 mL/min in column packing mode) |
| ÄKTA pure™ 150T | 0.01–150 mL/min (up to 300 mL/min in column packing mode) |
| Flow Accuracy | ÄKTA pure™ 25T: ±1.2% accuracy, RSD <0.5% (0.25–25 mL/min, <3 MPa, 0.8–2 cP) |
| ÄKTA pure™ 150T | ±1.5% accuracy, RSD <0.5% (1.0–150 mL/min, <3 MPa, 0.8–2 cP) |
| Pressure Range | ÄKTA pure™ 25T: 0–20 MPa |
| ÄKTA pure™ 150T | 0–5 MPa |
| Conductivity Range | 0.01–999.99 mS/cm |
| pH Measurement | 0–14 pH units, ±0.1 pH accuracy (pH 2–12) |
| Solvent Compatibility | Compatible with ≥1 mol/L NaOH and ≥2 mol/L NaCl for >3 hours of in-place cleaning per day |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA ready XL |
| Flow Rate Range | 45–3500 L/h |
| Compatible Column ID | up to 1200 mm |
| Primary Application | GMP-compliant large-scale bioprocess purification |
| Software Platform | UNICORN 7+ with OPC UA connectivity |
| Regulatory Support | FDA 21 CFR Part 11 compliant audit trail, GMP documentation package available |
| Sensor Type | Single-use, calibrated-in-place (CIP) pressure, UV, conductivity, and temperature sensors |
| Footprint | Compact industrial design optimized for multi-product facility integration |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA readyflux |
| Type | Single-Use Tangential Flow Filtration (TFF) System |
| Application Scope | Lab-Scale to Pilot-Scale Bioprocessing |
| Control Software | UNICORN 7.x or later |
| Compatibility | DeltaV™ DCS, ReadyToProcess Hollow-Fiber Cartridges, Xcellerex XDUO Single-Use Mixers, Third-Party Bag Mixers |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA ready™ 450 |
| System Type | Single-Use Preparative Chromatography Platform |
| Flow Rate Range | 0.01–45 mL/min |
| Hold-Up Volume | < 1.2 mL (system dead volume) |
| Pressure Limit | Up to 20 bar |
| Compliance | Designed for GMP-compliant small-scale bioprocessing |
| Sensor Integration | Integrated single-use conductivity, pH, UV, and temperature sensors |
| Fluidic Path | Pre-sterilized, gamma-irradiated disposable flow path kits |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ÄKTA ready™ |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | AKTAcrossflow |
| Application Scope | Lab-scale to process-development TFF for protein purification, cell harvesting, UF/DF, and membrane screening |
| Max Total Membrane Area | 150 cm² (3 × 50 cm² cassettes) |
| Minimum Working Volume | 25 mL |
| Control Software | UNICORN v7.x or later |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Fluid Path Materials | USP Class VI-certified elastomers, 316L stainless steel (pump head, valves), single-use compatible |