Dionex
Filter
Showing all 14 results
| Brand | Dionex |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DX-120 |
| Instrument Age | >10 Years |
| Pump Flow Rate | 0.5–4.0 mL/min |
| Max Pump Pressure | 4000 psi (27.5 MPa) |
| Conductivity Detector Range | 0–1700 µS |
| Temperature Compensation | 1.5–1.9%/°C |
| Detector Cell Volume | 1.25 µL |
| Operating Temperature | 10–40°C |
| Dimensions (H×W×L) | 60 × 30 × 40 cm |
| Weight | ~40 kg |
| Power Input | 100 V/50 Hz, 115 V/60 Hz, or 220–240 V/50 Hz |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-1000 |
| Pump Flow Range | 0.00–5.00 mL/min (0.01 mL/min increments) |
| Maximum Pressure | 5000 psi |
| Conductivity Detector Range | 0–15,000 µS |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Included Components | ICS-1000 Console, AS40 Autosampler |
| Compliance | Fully Tested & Certified per SpectraLab Scientific Pre-Delivery Protocol |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-1100 |
| Instrument Type | Ion Chromatograph |
| Usage Duration | 4 years |
| Warranty | 6 months |
| Compliance | ASTM D4327, ISO 14911, USP <645>, EPA Methods 300.0/300.1 |
| Software | Chromeleon® 7.2.10 or later |
| Detection Principle | Suppressed Conductivity Detection with Electrolytic Regeneration |
| Pump Material | PEEK (pH 0–14 compatible) |
| Max Pressure | 35 MPa |
| Flow Rate Range | 0.00–5.00 mL/min |
| Conductivity Detector Resolution | 0.00238 µS/cm |
| Data Interface | USB 2.0 |
| Column Oven Temp Range | 30–60 °C ±0.5 °C |
| Suppressor Types Supported | SRS®, AES®, MMS™ |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-1500 |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Column Heater Temp Range | Ambient +5 °C to 60 °C |
| Control Interface | Front-panel keypad and Chromeleon™ software |
| Compliance | ASTM D4327, ISO 10304-1, USP <645>, EPA Methods 300.0 & 317.1 |
| Software | Chromeleon 7.2.10 or later (FDA 21 CFR Part 11 compliant configuration available) |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-2000 |
| Pump Type | Dual-piston reciprocating, microprocessor-controlled fixed-stroke, variable-speed |
| Flow Rate Range | 0.05–5.0 mL/min (0.01 mL/min increments) |
| Max Pressure | 35 MPa (5000 psi) |
| Pressure Ripple | <1.0% |
| Flow Accuracy | ±0.1% |
| Flow Precision | <0.1% |
| Column Oven Temp Range | Ambient +5°C to 60°C (±1°C stability, ±2°C accuracy at 40°C) |
| EG Concentration Range | 0.1–100 mM |
| EG Flow Range | 0.1–3.0 mL/min |
| EG Max Pressure | 21 MPa (3000 psi) |
| Conductivity Detector | Digital signal processing, linear range 1% at 1 mS, resolution 0.00238 nS, detection range 0–15000 µS, cell volume <1 µL, temperature control range ambient +7°C to 55°C (stability ≤0.01°C) |
| Suppressor Power Supply | AESR (0–150 mA, 1 mA steps), SRS (0–500 mA, 1 mA steps) |
| Dimensions (H×W×D) | 56.1 × 22.4 × 53.3 cm |
| Weight | 24.5 kg |
| Power | 100–240 V AC, 47–63 Hz |
| Operating Environment | 4–40°C, 5–95% RH (non-condensing) |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ICS-2000 |
| Price | USD 17,800 (FOB) |
| Product Category | Chromatography |
| Usage Duration | 4–5 years |
| Warranty | 6 months |
| Instrument Model | ICS-2000 |
| Total Service Life | 6–8 years |
| Pump Type | Dual-piston reciprocating pump |
| Flow Rate Range | 0.05–5.0 mL/min (0.01 mL/min increments) |
| Max Pressure | 35 MPa (5000 psi) |
| Pressure Ripple | <1.0% |
| Conductivity Detector Cell Volume | <1 µL |
| Temperature Control Range (Column Heater) | Ambient +5°C to 60°C |
| Temp Stability | ±1°C |
| Electrolytic Eluent Generator Range | 0.1–100 mM |
| Suppressor Power Supply | AESR: 0–150 mA (1 mA step) |
| SRS | 0–500 mA (1 mA step) |
| Dimensions (H×W×D) | 56.1 × 22.4 × 53.3 cm |
| Weight | 24.5 kg |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-3000 |
| Pump Configuration | Single or Dual Pump (SP/DP) |
| Flow Rate Range | 0.001–10.0 mL/min |
| Max Operating Pressure | 35 MPa (5000 psi) |
| Detector Modules | Conductivity Detector (0–15,000 µS), Electrochemical Detector (Ag, Pt, Au, GC electrodes) |
| Eluent Generator | Single- or Dual-Channel EG with Programmable High-Voltage Power Supply & High-Pressure Degassing |
| Eluent Organizer | Dual EO slots, each supporting up to four 1-L/2-L or two 4-L bottles with simultaneous 4-channel pressurization |
| Auto-sampler | Supports Concentrated, Simultaneous, Sequential, and Sequential-Concentrated Injection Modes |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Compliance | Fully tested per SpectraLab Scientific QC protocol |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | ICS-3000 |
| Price | USD 21,500 (approx. based on ¥150,000 at 1 USD = ¥6.97) |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | ICS-5000 |
| Configuration Options | Dual-Pump (DP) or Single-Pump (SP) |
| Detector Modules | Conductivity, Pulsed Amperometric (PAD), Variable Wavelength UV (VWD), CAD, Fluorescence, MS-compatible |
| Autosampler | AS-AP |
| Operating Age | 3–4 years |
| Warranty | 6 months |
| Compliance | Fully serviceable per Thermo Fisher technical standards |
| Sample Introduction | Capillary, microbore, and standard-bore compatibility |
| Eluent Generation | RFIC™ EGC-KOH/EGC-MSA cartridges with 18-month cartridge life |
| Water Consumption | ≤5.25 L/year in capillary mode |
| Ready-State Functionality | Enabled for rapid system startup |
| Multi-dimensional Capability | IC×IC (2D-IC), IC-MS, IC-MS/MS, IC-ICP-MS support |
| Regulatory Readiness | Audit-ready configuration for GLP/GMP environments with optional 21 CFR Part 11-compliant software modules |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ICS-900 |
| Instrument Type | Laboratory Benchtop |
| Pump Pressure Range | 0–35 MPa |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate | 0.1–3.0 mL/min |
| Maximum Operating Pressure | 21 MPa |
| Operating Temperature Range | 30–60 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | UltiMate 3000 Nano |
| Configuration | LPG-3400M quaternary low-pressure micro-gradient pump, VWD-3400 variable-wavelength UV detector, FLM-3200 NANO flow manager (2P-10P & 2P-6P), WPS-3000T autosampler, SRD-3600 solvent rack with 6-channel degasser |
| Operational Age | 4 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and functionally validated per ISO/IEC 17025-aligned internal protocols |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | UltiMate 3000 |
| Configuration | LPG-3400A Quaternary Pump, WPS-3000TSL Analytical Autosampler, TCC-3000SD Column Compartment, VWD-3400RS Multi-Wavelength UV-Vis Detector, SR-3000 Solvent Rack with Integrated Degasser |
| Flow Rate Range | 0.2–10.000 mL/min |
| Pressure Range | 0.1–50 MPa |
| Gradient Delay Volume | 690 µL (360 µL optional) |
| Injection Volume | 1–90 µL (0.1–100 µL programmable) |
| Column Oven Temp. Range | 5–85 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Noise | ±0.25 × 10⁻⁵ AU (254 nm) |
| Drift | 1.0 × 10⁻⁴ AU/h |
| Warranty | 6 months |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | U3000 |
| Pump | LPG-3400SD Quaternary Low-Pressure Gradient Pump |
| Autosampler | WPS-3000SL Analytical |
| Detector | VWD-3100 Variable Wavelength UV-Vis Detector |
| Column Oven | TCC-3000RS |
| Software | Chromeleon™ 7.2 or later |
| Max Pressure | 62 MPa (620 bar) |
| Flow Rate Range | 0.001–10 mL/min |
| Injection Volume | 0.01–100 µL |
| Wavelength Range | 190–900 nm |
| Temperature Control Range | 5–110 °C |
| Warranty | 12 months |
| Brand | Dionex |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UVD-3000 |
| Price Range | USD 1,500–7,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 5–7 years |
| Warranty | 6 months |
| Wavelength Range | 190–740 nm |
