Ecom (Czech Republic)
Filter
Showing all 9 results
| Brand | Ecom (Czech Republic) |
|---|---|
| Origin | Germany |
| Model | ecom-CL2 |
| Instrument Type | Portable Flue Gas Analyzer |
| Standard Sensors | O₂ (electrochemical, long-life), CO (electrochemical, long-life, overload-protected) |
| Built-in Thermal Printer | Yes |
| Condensate Monitoring | Electronic cold trap detection |
| Housing | Anodized aluminum, wall-mountable & desktop-ready |
| Dimensions (closed) | 340 × 230 × 95 mm |
| Dimensions (open) | 340 × 350 × 180 mm |
| Weight | ~3.0 kg (complete system, no accessories) |
| Optional Sensors/Modules | NO (electrochemical), differential pressure probe, low-power Bluetooth module, ambient temperature sensor (with cable), manual soot sampling kit, 260 mm ambient temperature probe, dedicated sampling probe |
| Brand | Ecom (Czech Republic) |
|---|---|
| Origin | Germany |
| Model | ecom-D |
| Instrument Type | Portable Flue Gas Analyzer |
| Dimensions | ~220 × 125 × 85 mm |
| Weight | ~2 kg (including sampling system) |
| Housing | Anodized aluminum with integrated permanent magnet |
| Power | Rechargeable high-capacity battery |
| Display & Interface | Backlit LCD screen and tactile keypad |
| Connectivity | Integrated Bluetooth |
| Calibration | Automatic zero calibration on startup |
| CO Sensor Overload Protection | Yes, maintains continuity of other gas measurements |
| Standard Sampling System | Includes probe, fixed cone, and gas tubing |
| Optional Sensors (up to 6 total) | CH₄ (NDIR, 0–100%), H₂S (electrochemical, 0–1000 ppm or 0–5000 ppm), NOₓ (with 3.5 m or 5 m heated tube), O₂ (paramagnetic or electrochemical, reference O₂ adjustable down to 5%), temperature sensors (contact, surface, differential), pressure compensation, condensate level monitoring, Peltier gas cooler, ambient temperature sensor |
| Units | ppm, mg/m³, mg/kWh, % vol |
| Gas Pipeline Pressure Compensation | Automatic |
| Temperature Measurement Range | Configurable per probe type (e.g., flue exit vs. return flow) |
| Sampling Probe Options | 250–1500 mm standard |
| Brand | Ecom (Czech Republic) |
|---|---|
| Origin | Germany |
| Model | ecom-EN3 |
| Instrument Type | Portable Flue Gas Analyzer |
| Gas Sensors (up to 6) | O₂, CO, NO, NO₂, SO₂, CO₂ (NDIR) or CH₄ (NDIR), H₂S (electrochemical, 0–1000 ppm or 0–5000 ppm) |
| Temperature Measurement | Flue gas & ambient |
| Data Units | ppm, mg/m³, mg/kWh |
| Pump Flow Rate | up to 1.7 L/min |
| Dimensions | ~400 × 275 × 205 mm |
| Weight | ~7 kg (including probe assembly) |
| Optional Features | Peltier cooler with condensate detection, integrated 58 mm thermal printer, Bluetooth, SD card logging, iOS/Android app, automatic smoke opacity (DIN 51418-2), differential pressure flow measurement, auto-calibration, particulate filters for solid fuels |
| Compliance | Designed for EN 15267, EN 14181, VDI 3862, and applicable EU emission monitoring directives |
| Brand | ECOM (Czech Republic) |
|---|---|
| Origin | Germany |
| Model | ECOM-LSG |
| Instrument Type | Portable Gas Leak Detector |
| Detection Target | Methane (CH₄) |
| Measurement Range | 0–0.5% vol CH₄ |
| Response Time | <2 s |
| Operating Temperature | –5 °C to +40 °C |
| Sensor | Electrochemical or catalytic bead (field-replaceable) with temperature compensation |
| Display | 20×7 mm backlit LCD |
| Audio Alert | Configurable (on/off/headphone output) |
| Power Supply | 2×AAA batteries (standard or rechargeable kit optional) |
| Dimensions (W×H×D) | 155×35×22 mm |
| Probe | Flexible, 355 mm length |
| Weight | ~200 g |
| Accessories (Optional) | Rechargeable battery kit (batteries + charger), carrying case, headphone |
| Brand | Ecom (Czech Republic) |
|---|---|
| Origin | Germany |
| Model | EN3Tech |
| Type | Portable Flue Gas Analyzer |
| Detection Method | UV Absorption Spectroscopy + Electrochemical Sensors |
| Measured Gases | NO, NO₂, NOₓ, SO₂, CO |
| Compliance | CE, RoHS, EN 15267-3 (for portable emission monitoring systems), ISO 12039, ISO 10849, EPA Method 6C (UV for SO₂), EPA Method 7E (UV for NOₓ) |
| Operating Temperature Range | –10 °C to +50 °C |
| Sample Flow Rate | Adjustable up to 1.2 L/min |
| Dew Point Control | Peltier-cooled condenser with automatic condensate removal |
| Display | Backlit color graphical LCD with tactile keypad |
| Data Output | Integrated thermal printer + microSD card logging (up to 32 GB) |
| Optional Heated Sampling System | Up to 10 m heated line (0–500 °C), probe lengths 300–1500 mm, 3-channel anti-adsorption NOₓ line (2.7 m, PTFE-lined, 0–1100 °C thermocouple) |
| Brand | ecom (Czech Republic) |
|---|---|
| Origin | Germany |
| Model | J2KNpro |
| Instrument Type | Portable Flue Gas Analyzer |
| Sensor Capacity | Up to 9 sensors |
| Measurable Gas Components | Up to 11 |
| Detection Technologies | Electrochemical (EC), Non-Dispersive Infrared (NDIR), Ultraviolet (UV), Chemiluminescence Detection (CLD), Photoacoustic Spectroscopy (PAS), and Paramagnetic Oxygen (PEL) |
| Dimensions (Main Unit) | 510 × 330 × 250 mm |
| Dimensions (with Heated Sampling System) | 510 × 650 × 250 mm |
| Weight (Main Unit) | ~14 kg |
| Weight (with Heated Sampling System) | ~23 kg |
| Operating Ambient Temperature Range | 0–40 °C (auto-heating/cooling) |
| Condensation Management | Dual-stage Peltier cooler with electronic condensate level monitoring and automatic drainage |
| Gas Flow Rate | Up to 2.6 L/min (digital flow display) |
| CO Auto-Cut-off & Purge Function | Yes |
| Pre-Shutdown Fresh Air Purge | Yes |
| Intermittent Measurement Mode | Programmable (up to multi-day duration) |
| Data Output Units | ppm, mg/m³, mg/kWh, % vol |
| Pressure Compensation | Automatic |
| Calibration | Onboard one-touch calibration (full-system calibration performed in climate-controlled chamber) |
| Integrated Thermal Printer | Yes |
| Connectivity Options | Wi-Fi, Bluetooth, Ethernet, Radio Remote Control (868.135 MHz, CMIIT ID: 2011DJ0261 / 2011DJ0262) |
| Software | Free PC software + iOS/Android apps |
| Compliance | Designed for EN 15267, EN 14181, ISO 12039, ISO 10849, EPA Method 6C, EPA Method 7E, and applicable EU emission monitoring directives |
| Brand | Ecom (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PREPBOX A3L8E |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 50–250 mL/min |
| Flow Rate Reproducibility | ±0.5% RSD (at 500 mL/min) |
| Maximum Pressure | 30 MPa |
| Wavelength Range | 200–800 nm |
| Wavelength Accuracy | ±0.4 nm |
| Detector Type | TOY18DAD 800L Four-Channel UV-Vis Diode Array Detector |
| Gradient Capability | Low-Pressure Quaternary Mixing (up to 4 solvents) |
| Fraction Collection | 10-position Valve-Based Fraction Collector |
| Control Software | ECOMAC v4.x (Embedded PC Platform) |
| Dimensions (W×H×D) | 405 × 490 × 525 mm |
| Weight | 55 kg |
| Power Supply | 100–240 V AC, 400 W |
| Interfaces | 5× USB, HDMI, 2× RS232, LAN, VGA |
| Key | Brand: ECOM (Czech Republic) |
|---|---|
| Origin | Germany (assembled/quality-controlled) |
| Model | ecom-UNO / ecom-DP |
| Type | Portable differential pressure meters for flue gas and combustion system diagnostics |
| Measurement Range (ecom-UNO) | ±200 hPa |
| Resolution (ecom-UNO) | 0.01 hPa |
| Accuracy (ecom-UNO) | ±1% of reading |
| Overload Limit (ecom-UNO) | 300 hPa |
| Measurement Ranges (ecom-DP) | 0–7 kPa (high-res mode), 0–150 kPa (broad-range mode) |
| Resolution (ecom-DP) | 0.01 kPa (at ≤7 kPa), 0.1 kPa (at ≤150 kPa) |
| Accuracy (ecom-DP) | ±3% of reading |
| Power Supply | 2× AA 1.5 V (ecom-UNO), 3× AA 1.5 V (ecom-DP) |
| Dimensions (ecom-UNO) | 106 × 64 × 28 mm |
| Weight (ecom-UNO, incl. batteries) | ~150 g |
| Dimensions (ecom-DP) | 170 × 75 × 35 mm |
| Weight (ecom-DP, incl. batteries) | ~300 g |
| Display | Backlit graphical LCD (ecom-DP only) |
| Units | hPa, mmH₂O, PSI, mmHg (ecom-UNO) |
| Additional Functions | Min/Max hold, data hold, adjustable damping, programmable test routines (e.g., TRGI-compliant tightness testing), on-board logging (ecom-DP), PC software support (ecom-DP Logger) |
| Brand | Ecom (Czech Republic) |
|---|---|
| Origin | Germany |
| Model | ecom-ST (CEMS) |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Range | O₂, CO (H₂-compensated), optional CO₂, THC (IR), NO/NO₂, SO₂ |
| Sampling Flow Rate | 2.6 L/min |
| Cooling | Peltier-based gas cooler with condensate level sensing and automatic drainage |
| Communication | Modbus RTU, RS458 |
| Power Supply | 100–240 VAC |
| Enclosure Rating | IP52 (customizable to higher ingress protection) |
| Mounting | Wall-mounted |
| Calibration | 100% sensor calibration performed in controlled environmental chamber |
| Compliance | CE-marked |