Eigenbrodt
Filter
Showing all 14 results
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ANES 220 |
| Pricing | Available Upon Request |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | BUS125/KE |
| Collection Area | 500 cm² |
| Power Supply | 230 VAC, 50 Hz, max. 100 VA |
| Funnel Heating | 12 VDC, 50 W |
| Sample Heating | 12 VDC, 40 W |
| Sample Cooling | 12 VDC, 40 W |
| Operating Height | 1500 mm |
| Dimensions | H 1500 mm × Ø 315 mm |
| Weight | 35 kg |
| Funnel Material | DURAN® borosilicate glass |
| Temperature Control | Peltier-based heating/cooling, sample maintained at ~5 °C |
| Enclosure | Thick-walled PVC housing with lockable door |
| Compliance | VDI 3870, LAWA guidelines |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrumentation |
| Model | Optional Module Set for UNS130/NSA181/NSA181-K/NMO191 Systems |
| Pricing | Upon Request |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | LAM630 / LAM630R |
| Operating Temperature Range | −30 °C to +70 °C |
| Enclosure Height | 215 mm |
| Top Diameter | 290 mm |
| Base Diameter | 250 mm |
| Total Assembled Height (with mounting post) | 440 mm |
| Fan Supply | 12 V DC, 100 mA |
| Material | UV-stabilized ABS layers + high-strength opal PMMA top shield |
| Weight (uncalibrated) | 3.0 kg |
| Weight (calibrated version) | 3.3 kg |
| Sensor Capacity | 1–4 integrated probes (temperature, relative humidity, barometric pressure, CO₂, solar radiation, precipitation detection) |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | LTS 2000 |
| Sensor Type | Pt-100 (DIN EN 60751 / IEC 60751) |
| Measurement Range | −40 °C to +50 °C |
| Operating Temperature | −30 °C to +40 °C |
| Accuracy | ±0.2 K at 0 °C |
| Total Error | ±(0.3 °C + 0.005 × t °C), where t = absolute temperature in °C |
| Response Time (at 1 m/s airflow) | ≈25 s |
| Resistance Output | ≈80–120 Ω |
| Time Constant | <1 min |
| Resolution | <0.1 K |
| Tolerance Class | 1/3 Class B |
| Mounting Height | 5 cm above ground level |
| Compatible Enclosure | LAM 630 radiation shield |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NES 210 |
| Pricing | Available Upon Request |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | NILU SF 1 |
| Construction Material | HD-polyethylene |
| Support Frame | Stainless Steel |
| Collection Aperture Diameter | 200 mm (ISO-compliant) |
| Total Height | 400 mm (ISO-compliant) |
| Adjustable Mounting Height | 1.7–2.6 m above ground level (incl. ISO reference height) |
| Standard Kit | Sampler body with lid, stainless steel retaining ring, nested basket, ground stakes |
| Optional Accessories | Telescopic ground anchors (for rocky or paved surfaces), individual component replacement parts |
| Brand | Eigenbrodt |
|---|---|
| Country of Origin | Germany |
| Model | NMO191 |
| Measurement Parameters | pH, Electrical Conductivity, Precipitation Intensity, Cumulative Precipitation Volume |
| Temperature-Controlled Measurement Chamber | 4–7 °C (active refrigeration with auto-defrost) |
| Collection Area | 500 cm² |
| Compliance | VDI 3870 (German Association of Engineers) |
| Enclosure | Double-walled insulated PVC housing |
| Sensor Interface | RS 85 precipitation sensor (standard), optional IRSS 88 or NRS 80 |
| Control System | SIEMENS® LOGO® programmable logic modules |
| Sample Handling Options | Single-bottle (5 L HD-PE), 8-day sequential (8 × 750 mL or 8 × 1000 mL HD-PE), with bottom-heated bottle tray |
| Materials | Chemically inert components throughout (HD-PE, borosilicate glass optional), corrosion-resistant fittings |
| Cooling System | FCKW-free plate-evaporator refrigeration unit with forced ventilation and particulate filter |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | NSA 161/R T-N |
| Collection Area | 5000 cm² |
| Power Supply | 230 VAC / 50 Hz, max. 400 VA |
| Heating System | 2 × 200 W convection heaters, thermostatically controlled |
| Operating Height | 1500 mm (requires base) |
| Enclosure Dimensions | H 1250 mm × Ø 900 mm |
| Weight | Sampler 68 kg, Base 14 kg |
| Construction | Double-walled cylindrical polyethylene housing with mineral wool insulation |
| Funnel | Open-top PE funnel with integrated sharp-edged rim for total deposition sampling |
| Sample Containers | 4 × 20 L HD-PE bottles |
| Temperature Control | Maintains internal chamber above 0 °C during winter to prevent freezing and melt snow |
| Overflow System | Integrated bypass for excess precipitation after all bottles are filled |
| Volume Indication | Calibrated scale per bottle |
| Brand | Eigenbrodt |
|---|---|
| Country of Origin | Germany |
| Model | NSA 181 |
| Sampling Configurations | E-type (single 5–10 L HD-PE bottle), D-type (dual-week, two 5 L HD-PE bottles), S-type (8-day sequential, eight 1 L HD-PE bottles) |
| Heating | Bottom-heated sample bottles (D/S types) or heated collection chamber (E-type) |
| Control System | Siemens LOGO! programmable logic controller |
| Power Backup | Integrated rechargeable battery supporting ≥24 h operation during mains failure |
| Enclosure | Double-insulated PVC housing with automatic ventilation |
| Collection Area | 500 cm² polyethylene funnel compliant with VDI 3870 |
| Sensor Interface | RS 485-compatible precipitation sensor (e.g., RS 85, NRS 80, IRSS 88) |
| Materials | Chemically inert HD-PE, DURAN® borosilicate glass, or PTFE components |
| Data Logging | Integrated LCD timer + digital data recording system |
| Structural Base | Galvanized steel mounting frame |
| Compliance | Designed per VDI 3870 |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | NSA181 |
| Application | Mercury (Hg) speciation sampling, wet/dry deposition monitoring, dual- or tri-weekly fractionated collection |
| Cooling | Continuous refrigerated sample chamber (4 °C) |
| Sample Allocation | Motorized multi-bottle distributor (3-position standard) |
| Material Compatibility | Borosilicate glass (DURAN®) and PTFE-wetted surfaces |
| Environmental Certification | Compliant with EN 14211, ISO 10473, and EU Directive 2004/107/EC for heavy metal deposition monitoring |
| Data Interface | RS-485, analog outputs, GSM-enabled telemetry (optional) |
| Power Options | 230 V AC / 12 V DC auto-switching |
| Optional Accessories | IRSS 88 infrared precipitation sensor, snow cover kit, magnetic isolation valve, GLP-compliant audit trail logging (via optional software module) |
| Brand | Eigenbrodt |
|---|---|
| Country of Origin | Germany |
| Model | NSA181/K-TYPE |
| Sampling Configurations | E-type (single 5–10 L bottle), D-type (dual 5 L weekly bottles), S-type (eight 1 L daily bottles) |
| Collection Area | 500 cm² |
| Temperature Control Range | 3–10 °C (standard operating setpoint: 4–6 °C) |
| Cooling Medium | R134a (CFC-free) |
| Sensor Interface | RS 85 precipitation sensor (standard) |
| Enclosure | Double-walled insulated PVC cabinet |
| Materials | Chemically inert components (HD-PE, DURAN® borosilicate glass, quartz options available) |
| Compliance | VDI 3870-compliant funnel geometry and material specification |
| Control System | SIEMENS® LOGO! programmable logic controller |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | RS85 / RS85OP / NRS80 |
| Power Supply | 24 V DC/AC (RS85/RS85OP: max. 20 W |
| NRS80 | max. 700 mA, half-wave rectified) |
| Output | Dry-contact relay (NO/NC), 100 V DC / 250 V AC, 5 A, 1250 VA |
| Sensing Area | RS85/RS85OP ≈ 60 cm² |
| Activation | Instant on-rain detection |
| Deactivation Delay | 0–270 s adjustable in 30 s increments |
| Heating | Dual-stage proportional electronic heating (24 V DC) |
| Enclosure Rating | IP65 |
| Dimensions | RS85/RS85OP 83 × 83 × 85 mm, 700 g |
| Compliance | Designed for continuous outdoor deployment in meteorological and environmental monitoring networks |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | UNS 130D/E |
| Collection Area | 500 cm² |
| Precipitation Sensor | RS 85 (binary yes/no output) |
| Power Supply | 230 VAC, 50 Hz, max. 250 VA |
| DC Heater Supply | 24 V DC, 2 × 30 W |
| Funnel Cover Drive Motor | 24 V DC, 50 W |
| Overall Height (with base) | 1500 mm |
| Dimensions (H × L × W) | 800 × 470 × 350 mm |
| Sampler Weight | 46 kg |
| Base Weight | 17 kg |
| Standard Configuration | Thick-walled PVC housing, HD-PE funnel, 5 L HD-PE sample bottle, lockable aluminum control cabinet with electronics and drive unit, thermostatically controlled heating system, RS 85 precipitation sensor |