| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | 45D |
| Chamber Construction | Stainless Steel Enclosure with Polycarbonate Viewing Window |
| Test Angle | Fixed 45° Specimen Mounting |
| Applicable Standards | ASTM D3823, ISO 6927 (adapted), UL 94 HB/VTM-0 pre-screening context, KSL 2017 (Korean Standard for Surface Burning Characteristics) |
| Burner Options | Air-Mix Burner & Micro/Meker Burner |
| Flame Impingement Control | Adjustable Pressure Regulators for Both Burners |
| Timing System | Dual Independent Digital Timers (Afterflame Time & Afterglow Time) |
| Specimen Thickness Limit | ≤5 mm |
| Sample Types | Rigid & Semi-Rigid Flat Panels (Wood, Metal, Plastic Laminates, Paperboard, Thin Composites) |
| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | HCF-NEK606 |
| Chamber Dimensions (W×D×H) | 1220 × 1045 × 1100 mm |
| External Dimensions (W×D×H) | 1300 × 1125 × 950 mm |
| Frame Material | 50×50×t3 mm Stainless Steel 304 |
| Burner Tube ID | Ø36 mm, SS304 |
| Venturi Mixer | Air/Propane Premixing |
| Air MFC | 77.7 ± 4.8 SLPM (180 L/min) |
| Propane MFC | 15 SLPM (13.5 ± 0.5 L/min) |
| Temperature Sensors | K-type (Ø8.0 mm) & R-type (Ø8.0 mm) Thermocouples |
| Data Acquisition | PC-connected DAQ with Bluetooth antenna pair |
| Control Rack Dimensions | 730 × 650 × 1600 mm, Aluminum Alloy |
| Safety System | Automated Ignition, Interlocked Door, Flame-Out Detection |
| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | IEC 60754-1&2 |
| Compliance | IEC 60754-1 Ed. 2.0 b:1994, IEC 60754-2 Ed. 1.0 b:1991, GB/T 17650 |
| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | SB 2005 |
| Chamber Internal Dimensions | 914 × 914 × 610 mm |
| Wall Finish | Enamel-coated steel |
| Radiation Source | Optional ISO 5659-2 compliant conical heater (0–50 kW/m²) |
| Photodetector | S4 spectral response photomultiplier tube (dark current <10⁻⁹ A) with silicon photodiode backup |
| Temperature Monitoring | Digital display with calibrated thermocouple |
| Data Acquisition | Integrated software compliant with ISO 5659-2 reporting requirements |
| Gas Sampling | Dedicated port for detector tubes (e.g., CO, HCl, HCN) |
| Calibration | NIST-traceable radiometric calibration certificate available for heat flux meter |
| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | SBI |
| Compliance | EN 13823, GB/T 20284 |
| Measurement Principle | Oxygen Consumption Calorimetry & Optical Smoke Density Analysis |
| Heat Flux | 31 kW Propane Corner Burner (250 mm × 250 mm × 80 mm) |
| Test Chamber | 3 m × 3 m × 2.4 m (L × W × H) |
| Sampling Duct | Integrated multi-sensor zone for O₂, CO, CO₂, temperature, smoke obscuration (via light extinction), and volumetric flow |
| Data Acquisition | Analog inputs for thermocouples (K-type), differential pressure sensors, gas analyzers |
| Gas Analysis System | Siemens OXYMAT 61 (paramagnetic O₂, 0–25% vol, ±1% FS/week drift, <3 s response) + U23 NDIR (CO: 0–1%, CO₂: 0–10%, ±1% FS/week, <3 s response) |
| Smoke Measurement | Laser-based optical density (OD) at 532 nm, calibrated per ISO 5659-2 |
| Flame Spread Assessment | Lateral Flame Spread (LFS) time to 1.5 m × 1.0 m specimen edge |
| Key Outputs | FIGRA (Fire Growth Rate Index), THR (Total Heat Release), SMOGRA (Smoke Growth Rate Index), TSP (Total Smoke Production), LFS, Droplet Formation Observation |