Generic
Filter
Showing 1–30 of 1024 results
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | 4110Bo |
| Pricing | Upon Request |
| Origin | United Kingdom |
|---|---|
| Type | Benchtop Centrifuge |
| Maximum Speed | 10,000 rpm |
| Maximum RCF | 12,300 × g |
| Rotor Type | Fixed-angle |
| Standard Rotor Capacity | 12 × 1.5/2.0 mL tubes |
| Optional Rotor Capacity | 32 × 0.2 mL PCR tubes |
| Acceleration Time | <12 s |
| Deceleration Time | <16 s |
| Rotor Material | Corrosion-resistant polymer |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Display | LCD |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 201/525 |
| Instrument Type | Ultraviolet-Visible (UV-Vis) Detector |
| Noise | < ±1.0 × 10⁻⁵ AU @ 254 nm |
| Wavelength Range | 190–800 nm |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Precision | ±1.0 nm |
| Optical Design | Single-Wavelength (201) / Dual-Wavelength (525) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | 502 |
| Instrument Type | Fluorescence Detector (FD) |
| Excitation/Emission Wavelengths | Dual-Programmable |
| Spectral Range | Broad (Typical UV-Vis, e.g., 200–700 nm) |
| Bandwidth Options | Multiple Fixed and Variable Slit Widths |
| Sensitivity | High (Sub-picomolar Detection Limit for Standard Fluorophores) |
| Noise Level | Ultra-Low (RMS < 0.5 mV at 1 s time constant) |
| Scan Mode | Point-Scan Fluorescence Acquisition |
| Spectral Storage Capacity | ≥64 Predefined Method-Linked Spectral Profiles |
| Dynamic Range | >4 Orders of Magnitude (Linear Response from 10⁻¹² to 10⁻⁸ M for quinine sulfate equivalent) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 6000 |
| Instrument Type | Ultraviolet-Visible (UV-Vis) Diode Array Detector |
| Detection Limit | 0.1 µg/L (typical, based on caffeine in methanol/water, 254 nm) |
| Precision | ≤0.2% RSD (retention time and peak area, n=6) |
| Flow Rate Compatibility | 1 µL/min to 20 mL/min |
| Optical Path Length | 50 mm LightPipe flow cell (patented) |
| Origin | Japan |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | FS-i |
| Price Range | USD 1.50 – 750.00 |
| Response Time | ≤0.5 s |
| Protection Rating | IP65 (Display & Weighing Pan) |
| Readability Options | 1/3000, 1/6000, 1/7500, 1/12000 or 1/15000 of Capacity |
| Display Height | 18.6 mm |
| Analog Bar Graph | 60-segment backlighted |
| Battery Life | Up to 80 h (fully charged, 15 h charging time) |
| Auto Power-Off | After 5 min at zero |
| Memory | 100 preset target weights with upper/lower limits |
| Calibration | Internal calibration with standard weight |
| Communication Interfaces | Optional RS-232 + relay (FS-03i) or RS-422/485 + relay (FS-04i) |
| Units | kg, g, lb, oz |
| Tare Function | Pre-set tare memory |
| Power Supply | AC adapter or optional sealed lead-acid rechargeable battery |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AAM Adsorbent Material Filter |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AnalyzeIT Wet Process Analyzer |
| Price Range | USD 140,000 – 280,000 (based on CIF terms) |
| Instrument Principle | Fourier Transform Near-Infrared (FT-NIR) Spectroscopy |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MR304/170 |
| Instrument Type | Fourier Transform Infrared Spectrometer |
| Spectral Resolution | Adjustable up to 1 cm⁻¹ |
| Data Interface | 100 Mbps Ethernet |
| Scan Speed | ≥83 Hz (12 ms per interferogram) |
| Field of View Options | 5 mrad, 28 mrad, 75 mrad |
| NESR | <1.0 × 10⁻⁹ W·cm⁻²·sr⁻¹·cm |
| Compliance | ASTM E1421, ISO 18356, MIL-STD-461G (EMC), GLP/GMP-ready data audit trail |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PGC2000 Series |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | PIR3502, PFO3372, PUV3402 |
| Operating Principle | In-situ, Online & Portable |
| Spectral Ranges | UV (190–400 nm), VIS (400–700 nm), NIR (700–2500 nm), IR (2.5–25 µm) |
| Wavelength Channels | Up to 8 discrete optical bands |
| Integration | Compatible with VN2300 Analyzer Network |
| Sampling Interface | Direct path (PIR3502/PUV3402) and fiber-optic probe (PFO3372) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RVP4500 Series |
| Pricing | Available Upon Request |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Manufactured in Taiwan |
| Model | Abrasion Tester 339 |
| Pricing | Available Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ACC Amide Compressor Cooler |
| Pricing | Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACC Environmental Pre-Cooler |
| Pricing | Available Upon Request |
| Key Features | Internal Chamber Dimensions – Ø250×450 mm (OK-PTC-25) / Ø350×500 mm (OK-PTC-35) |
|---|---|
| Temperature Range | RT+10°C to 132°C |
| Humidity Range | 100% RH (saturated steam environment) |
| Pressure Range | 0.0–2.8 kg/cm² (gauge), max working pressure 3.0 kg/cm² (safety capacity: 4.0 kg/cm²) |
| Temperature Uniformity | ±1.5°C |
| Temperature Control Accuracy | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Pressurization Time | ~30 min (0.0 → 2.0 kg/cm²) |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Casing | SECC cold-rolled steel with electrostatic powder coating |
| Compliance | ASTM D257, DIN 50017, ISO 2231, IEC 60068-2-13, JIS Z 2243, MIL-STD-810H, NACE TM0169, UL 746C |
| Key | Internal Chamber Dimensions (PCT-25): Ø250 × 450 mm (D) |
|---|---|
| Internal Chamber Dimensions (PCT-35) | Ø350 × 500 mm (D) |
| Temperature Range | RT+10°C to 132°C |
| Humidity Range | 75–100% RH |
| Pressure Range | 0.0–2.8 kg/cm² (gauge), max safety capacity 4.0 kg/cm² |
| Temperature Uniformity | ±1.5°C |
| Temperature Control Accuracy | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Pressurization Time (0 → 2.0 kg/cm²) | ~30 min |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Casing | SECC steel with electrostatic powder coating |
| Control System | Delta color touchscreen PLC (PT-100 sensor), PID-controlled saturated steam temperature & humidity, analog pressure gauge, LED digital timer & temperature display, auto-water replenishment system |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuSeris (Sentinel) |
| Pricing | Upon Request |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACE |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACM-200+ |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Form Factor | PCI Slot-Based Mainframe |
| Channel Capacity | Up to 112 Channels (Configurable via PCI-8 or PCI-2 AE Acquisition Cards) |
| Compliance | Designed for ASTM E1316, ISO 12713, and EN 1330-9 Conformance |
| Interface | PCI Express Backplane with Synchronized Sampling Architecture |
| Power Supply | Industrial-grade 100–240 VAC, 50/60 Hz |
| Operating Temperature | 0–50 °C |
| Storage Temperature | –20–70 °C |
| Dimensions (W×D×H) | 483 × 500 × 177 mm (Standard 4U Rack-Mount Chassis) |
| Weight | ≤18 kg |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACP-ASR25 |
| Pricing | Available Upon Request |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ACQ-06 |
| Pricing | Available Upon Request |
| Instrument Type | Liquid Chromatography Column Switching Module |
| Fluidic Path Materials | SS316L, PTFE, ETFE, PEEK |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ACV Condensate Collector |
| Pricing | Upon Request |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DP8000 |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror–Compensated Semiconductor Sensor (Dew-Point-Specific Thermoelectric Cooling) |
| Operating Temperature | -10 °C to +50 °C |
| Accuracy | ±1 °C (Td, at stable conditions, -60 °C to +20 °C range) |
| Repeatability | ±1 °C |
| Dew Point Range Options | -80 °C to +20 °C |
| Resolution | 0.1 °C (Td) or 0.1 ppmv |
| Response Time (63%/90%) | 5 s / 45 s (-20 °C → -20 °C Td) |
| Gas Flow Rate | 0.1–0.4 L/min (H₂), 0.5–0.9 L/min (SF₆) |
| Pressure Rating | 0–1.0 MPa (operational), 0–20 bar (mechanical) |
| Probe Protection | Stainless Steel Sintered Filter |
| Power Supply | 110–220 VAC / Internal Li-ion Battery (auto-switching, overcharge/over-discharge protection) |
| Data Interface | USB (class-compliant, no driver required), RS232 |
| Storage Temperature | -40 °C to +70 °C |
| Dimensions & Weight | 300 × 200 × 260 mm, 3.5 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TCLP |
| Price | USD 35,000 (FOB) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | expression |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC003-Daisy564 |
| Pricing | Available Upon Request |
| Measuring Volume (mm) | 500 × 600 × 400 |
| Maximum Permissible Error (MPE) E0,MPE (� | m): 2.2 + L/300 |
| Probe Form Error (PFE) (� | m): 2.2 |
| Maximum Workpiece Load (kg) | 500 |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AET Extension Tube |
| Pricing | Upon Request |